1 / 13

PIXEL Mechanical

PIXEL Mechanical. H. Wieman face to face Integration 15-May-2008. topics. Introduction – mechanical design Pixel specifications and parameters Review insertion mechanics Kinematic mounts air flow analysis cooling air requirements. Pixel geometry. End view. 8 cm radius. 20 cm.

quin-ortega
Télécharger la présentation

PIXEL Mechanical

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. PIXEL Mechanical H. Wieman face to face Integration 15-May-2008

  2. topics • Introduction – mechanical design • Pixel specifications and parameters • Review insertion mechanics • Kinematic mounts • air flow analysis • cooling air requirements

  3. Pixel geometry End view 8 cm radius 20 cm 2.5 cm radius Inner layer Outer layer  coverage +-1 One of two half cylinders total 40 ladders

  4. Some pixel features and specifications critical and difficult (ATLAS Pixels 1.2%)

  5. New details on kinematic mounts

  6. Pixel kinematic mounts

  7. Pixel kinematic mounts

  8. Pixel kinematic mounts

  9. Pixel kinematic mounts

  10. Pixel kinematic mounts

  11. preliminary air flow study • ANSYS CFX FEE Flow analysis • simplified geometry to limit mesh • input velocity 8 m/s down module support tube • ISC blank off to force return flow over silicon surfaces • Result: • good flow velocity over both inner and outer silicon

  12. Pixel air cooling system Air flow: 400 SCFM Total pressure drop: 22 inches water Temperature: 75 deg F/34 deg C or maybe -10 deg C Wide angle hall ISC external duct 6 in diameter X 50 ft Internal duct 2 in diameter X 5 ft chiller Internal duct 2 in diameter X 5 ft pump external duct 6 in diameter X 50 ft

  13. Pixel heat load break down

More Related