An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Accuracy of CV determination systems for calculation of FWACV Dave Lander Update 12th October 2011

  2. Overview • Based on work previously carried out October 2006 • Examines how consumers gas bills are estimated • Examines how the accuracy of all of the inputs into the calculation affects the overall accuracy of the gas bill • Poses questions about: • fairness • the appropriate level of acuracy Accuracy of CV determination systems - Page 2

  3. Introductory concepts: error, uncertainty, bias... • Uncertainty • "Parameter that characterises the spread of values that could reasonably be attributed to the measurand." • Range and an associated probability • Error • Measured result minus a “true” value • Bias • Mean value of a distribution of errors. • Associated with an agreed set of conditions (each showing an error) Accuracy of CV determination systems - Page 3

  4. The Charging Area CV • Charging area CV is calculated as the Flow weighted average CV • Subject to a 1 MJ/m3 cap • Uncertainty in FWACV arises from: • Uncertainty in measurement of CVs and flows • Variation in the CV of the sources of gas Accuracy of CV determination systems - Page 4

  5. The Charging Area CV • Consumer A receives high CV gas “all the time” • For him the FWACV is biased • Consumer B receives low CV gas “all the time” • For him the FWACV is biased • FWACV delivers zero bias in charging area energy • CV cap limits the exposure of consumer B B A Accuracy of CV determination systems - Page 5

  6. The Consumers’ Energy Bill • Energy = quantity of gas x representative calorific value • Quantity is expressed as volume at reference conditions • Consumer: • actual metered volume x conversion factor • conversion factor is provided in the Regulations • Representative calorific value represents the CV of the gas seen by the consumer • Consumer: • average of charging area CVs over the billing period • determined through use of approved CVDDs Accuracy of CV determination systems - Page 6

  7. Sources of Error, bias and Uncertainty • FWACV • Daily volumes at Network Offtakes • Error, bias in daily volumes • CVs at Network Offtakes • Error, bias in CVs • Actual gas quality received • Variation in gas quality • “Location” uncertainty • Quantity of gas • Error, bias in domestic meter • Error, bias in conversion factor B A Accuracy of CV determination systems - Page 7

  8. Estimating error, bias and uncertainty • Principles suggested by Marcogaz Energy Measurement Working Group • Provides guidance on implementation of OIML Recommendation “Gas Metering” • Estimates errors and bias in each component of measurement, which are then combined arithmetically to provide and overall bias in energy measurement • Estimates uncertainties in bias for each source, which are then combined in quadrature to provide an overall uncertainty in bias. • Sources: measurement instrumentation; fixed factors; representative CV calculation Accuracy of CV determination systems - Page 8

  9. Estimating error, bias and uncertainty • Domestic meter bias and uncertainty • Fixed factor bias and uncertainty • Compare with average and variance in pressure, temperature, altitude • Matrix of FWACV scenarios: • Uncertainty in CV determination at NTS Offtakes • 0.125%, 0.25%, 0.5% (i.e. 0.05, 0.10, 0.20 MJ/m3) • Uncertainty in NTS offtake metering • 1%, 4% Accuracy of CV determination systems - Page 9

  10. Results: Consumers’ energy bills • Current situation • MPE in CV determination is 0.25% • MPE in Offtake volume metering is 1% • Overall bias is close to zero (-0.081%), because: • Daily CVs and volumes, and hence FWACV, assumed to be unbiased • Small bias arises from assumptions in fixed factor in the Regulations • Expanded uncertainty in bias is 5.8% • 61% of variance arises from temperature variation • 25% of variance arises from CV variation (i.e. 1 MJ/m3 cap) • 9% of variance arises from domestic meter • 0.06% of variance arises from FWACV uncertainty Accuracy of CV determination systems - Page 10

  11. Results: Consumers’ energy bills • Current situation • MPE in CV determination is 0.25% [0.5%] • MPE in Offtake volume metering is 1% • Overall bias is close to zero (-0.081%), because: • Daily CVs and volumes, and hence FWACV, assumed to be unbiased • Small bias arises from assumptions in fixed factor in the Regulations • Expanded uncertainty in bias is 5.817% [5.822%] • 61% of variance arises from temperature variation • 25% of variance arises from CV variation (i.e. 1 MJ/m3 cap) • 9% of variance arises from domestic meter • 0.06% of variance arises from FWACV uncertainty [0.22%] Accuracy of CV determination systems - Page 11

  12. Results: Consumers’ energy bills (impact of biomethane) • Current situation • MPE in CV determination is 0.25% [biomethane 10 MJ/m3, or 25%] • MPE in Offtake volume metering is 1% [biomethane 3%] • Overall bias is close to zero (-0.081%), because: • Daily CVs and volumes, and hence FWACV, assumed to be unbiased • Small bias arises from assumptions in fixed factor in the Regulations • Expanded uncertainty in bias is 5.817% [5.818%] • 61% of variance arises from temperature variation • 25% of variance arises from CV variation (i.e. 1 MJ/m3 cap) • 9% of variance arises from domestic meter • 0.06% of variance arises from FWACV uncertainty [0.08%] Accuracy of CV determination systems - Page 12

  13. Points for discussion • Overall, consumer billing is largely unbiased, provided assumptions about CV measurement and domestic and offtake metering are appropriate. (This can be part of a specification.) • Some consumers experience bias and are under- or over-billed, largely because of temperature CV variation. • This is as fair as the current system can get; suppliers and gas transporters don’t gain. The cap limits the exposure of the worst affected (although arguably at the expense of bias in LDZ energy). • Doubling the uncertainty in CV determination at NTS Offtakes has little impact. • Uncertainty in CV determination at small entry points is unlikely to have significant impact (although yet to be modelled). • Cheap and cheerful CV measurement in Smart meters? Accuracy of CV determination systems - Page 13

  14. Typical Inferential-type CVDDs uncertainty in GCV • GasPT2 – 0.2-0.75%, depending on CO2 content • EMC 500 – 0.2-0.5% • Gas-lab Q1 – 0.4% Title of Presentation - Page 14