Background

Overview/Update of EPA’s Mercury Emissions Monitoring Program Scott Hedges, USEPA, CAMD EPRI CEM Users Group Meeting Phoenix, AZ May 9 - 11, 2007. Background. The Clean Air Mercury Rule (CAMR) requires sources to install and certify mercury monitoring systems by January 1, 2009

rhonda
Télécharger la présentation

Background

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Overview/Update of EPA’s Mercury Emissions Monitoring ProgramScott Hedges, USEPA, CAMDEPRI CEM Users Group MeetingPhoenix, AZMay 9 - 11, 2007

  2. Background • The Clean Air Mercury Rule (CAMR) requires sources to install and certify mercury monitoring systems by January 1, 2009 • Affected sources have begun ordering monitoring and data acquisition systems • Vendors have expressed a high level of confidence that continuous mercury emission monitoring systems will be available to meet industry needs and CAMR requirements

  3. Background • Development of the CAMR monitoring program has been a collaborative effort between EPA (OAQPS, ORD, CAMD), NIST and industry (EPRI, RMB, WRI, EERC and others) • EPA continues its full commitment to working with utilities, vendors, academia, NIST, and other organizations to successfully develop all aspects of the CAMR mercury monitoring program • Most major technical issues are behind us but some challenges remain

  4. Mercury Monitoring – Next Steps • Promulgate instrumental and sorbent-based mercury reference methods • Develop NIST-traceable calibration gases and protocols • Develop training materials and conduct training for EPA Regions, States and sources • Ordering, installation and certification of monitors by sources • Collect, quality assure, and report data

  5. Availability of Alternative Reference Methods EPA is preparing a rule package for both the instrumental and sorbent-based reference methods • Process being expedited through direct final rule making effort • Final rule tentatively scheduled for early August publication in the Federal Register • Would become final in October if no adverse comments are received

  6. Proposed Monitoring Changes to Part 75 • Proposed Part 75 rule changes published August 22, 2006 • Comment period closed in October 06 • Reference Method 29 proposed as an alternative Ontario Hydro reference method • Minor technical/procedural changes proposed to Subpart I of Part 75 including adding multiple/common stack heat input procedures • Solicited comments relating to the development of reference method based on sorbent trap technology • Received comments were not extensive - essentially supportive of changes • Rule expected to become final late summer

  7. Additional Hg-Related Part 75 Changes being Considered • Possible changes to Subpart B (Monitoring Provisions) and Appendix K being considered for inclusion in the Alternative Reference Method Rule Package • Providing minor clarifications to the Hg monitoring and measurement provisions • Requiring same type of sorbent material used during an Appendix K RATA also be used during daily operation • Allowing smaller sorbent traps to be used during an Appendix K RATA than used during daily operation • will reduce the required sampling time per run • Removing spike recovery normalization correction to sorbent trap monitoring systems • Tightening spike recovery acceptance criteria for sorbent trap monitoring systems • Providing alternatives to dry gas meters in Appendix K (e.g., allowing the use of thermal mass flow meters)

  8. NIST-Traceable Hg Calibration Standards • EPA and NIST continue their collaborative work to provide NIST traceability for elemental and oxidized mercury calibration standards • We are expecting to have NIST-traceability protocol documents this year for use in certifying CEMS and sorbent trap monitoring systems

  9. NIST-Traceable Hg Calibration Standards To date EPA: • Has prepared working draft elemental mercury gas generator traceability protocol • Will be incorporating user-friendly uncertainty calculation spreadsheets into the draft • Working draft has been sent to vendors • Is preparing oxidized mercury gas traceability protocol

  10. NIST-Traceable Hg Calibration Standards To date NIST: • Has developed draft certification procedures for elemental and oxidized mercury gas generators (vendor-prime generators) • Invited generator vendors to come in and begin certifying elemental mercury gas generators

  11. Mercury Monitoring – Other Issues • Allow time for adequate installation and certification of monitors • If you’re planning on reporting emissions using the Low Mass Emissions (LME) option, make sure your unit qualifies • If you’re installing an FGD and new stack(s) in 2009, consider petitioning the Agency for relief

  12. Questions? Comments? THANK YOU!