1 / 9

Statement of Interest in CMS MPGD High-  Muon Upgrade Florida Tech CMS Muon Group

Statement of Interest in CMS MPGD High-  Muon Upgrade Florida Tech CMS Muon Group. Marcus Hohlmann Florida Institute of Technology, Melbourne, FL, USA. Workshop on CMS high-  muon upgrade - CERN, Sep 30, 2010. Overview. Currently Existing GEM Work at Florida Tech

rmelody
Télécharger la présentation

Statement of Interest in CMS MPGD High-  Muon Upgrade Florida Tech CMS Muon Group

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Statement of Interest inCMS MPGD High- Muon UpgradeFlorida Tech CMS Muon Group Marcus Hohlmann Florida Institute of Technology, Melbourne, FL, USA Workshop on CMS high- muon upgrade - CERN, Sep 30, 2010

  2. Overview • Currently Existing GEM Work at Florida Tech • Experience with GEM detector construction & operation • R&D for CMS High- muon upgrade • GEM readout electronics & DAQ within RD51 SRS project • Proposed Contributions to CMS High- Upgrade • Primary: CMS GE1/1 Detector Production & Test Facility • Secondary: Contribute to Readout & DAQ Development • Fl. Tech Facilities Available for Upgrade Project • Support Needed from USCMS, DOE M. Hohlmann - Florida Tech Statement on Participation in CMS High-eta Muon Upgrade Project

  3. GEM Track Record • Construction and Testing of Triple-GEM detectors • Small prototypes (2cm  2cm, 10cm  10cm) since 2004 • Small series production of ten 30cm  30cm detectors in 2009 & 2010 • RD51’s Common “Scalable Readout System” for MPGDs in 2010 • Software development for SRS DAQ system (in ALICE DATE environment) • Frontend hybrid card: PCB with APV25 chip(used in CMS Si Tracker) • Two recent publications on 30cm  30cm GEM detector design and performance (IEEE NSS ’09 proc., NIM article submitted for SORMA ‘10 proc.) • Four publications on GEM application (muon tomography, DHS) • RD51 charter member (2008) • Assoc. Partner in CMS CUPID proposal (MPGDs) - Marie Curie ITN fellowships (2009) • Active participant in CMS high- upgrade group since early 2010: Investigating production techniques for GE1/1 detectors at Florida Tech • Stretching of CMS GE1/1 GEM foils • Honeycomb spacers • Team: MH, 1 post-doc (Kondo Gnanvo), 4 grad students (Mike Staib, Bryant Benson, Lenny Grasso, Amilkar Quintero (grad.)), several undergrads M. Hohlmann - Florida Tech Statement on Participation in CMS High-eta Muon Upgrade Project

  4. Ten Triple-GEM Detectors Transfer of know-how from GDD Eight detectors built at CERN (30cm  30cm active area) Two detectors built at Florida Tech using innovativeconstruction method Both detectors working 8 keV X-rays mips M. Hohlmann - Florida Tech Statement on Participation in CMS High-eta Muon Upgrade Project

  5. R&D - CMS High- upgrade New, cost-effective GEM foil thermal stretching technique via infrared heating under clean room conditions in our high- bay lab (RD51 Technical Note in prep.) CMS high- prototype drift foil Works well ! along long side of frame M. Hohlmann - Florida Tech Statement on Participation in CMS High-eta Muon Upgrade Project

  6. Readout Electronics & DAQ RD51 is developing a commonScalable Readout System for MPGD’s : • from few 100 to ~105 channels • full hardware chain currently being tested Hans Müller Sorin Martoiu (CERN) VFAT here for CMS high- det. common DAQ part – could be used for CMS high- GEMs • Florida Tech’s current contributions to Scalable Readout System • Trying to get commercial production of ~200 hybrid front-end PCB’s going (for APV25 chip) • DAQ software development (DATE for SRS) together with ALICE DATE experts • Event monitoring (AMORE for SRS) with ALICE DATE experts • First demonstration of chain APV+SRS+DATE+AMORE achieved • First integration tests of SRS with our 30cm × 30cm GEM detectors • Largest projected user of SRS to-date (~15k ch.) APV25 test pulses with a 128 ch. readout M. Hohlmann - Florida Tech Statement on Participation in CMS High-eta Muon Upgrade Project

  7. Proposed Fl. Tech Contributions to CMS High- Project • Long-term • Main interest: GE1/1 Detector Production & Testing Site • Expand current setup in clean room for parallel production • Adapt SRS DAQ for detector testing procedures • Set up cosmic ray stand and X-ray source for post-production testing • Secondary interest:DAQ & Event Monitoring • Adapt s/w for VFAT if CMS decides to go with an SRS-based system • Short-term & Medium-term • Set up GEM foil testing box (measure leakage currents under gas) • Construct and test a prototype detector (following current CERN design) at Florida Tech using our IR stretching technique • Contribute to beam tests of prototypes • Continue R&D on series production techniques M. Hohlmann - Florida Tech Statement on Participation in CMS High-eta Muon Upgrade Project

  8. T3 Available Facilities • GE1/1 Production & Testing • Large clean room for production (~ cl. 1,000) • Small clean room for R&D (~ cl. 10,000) • Space in 350 m2 high-bay area for test stands • Gas detector lab (HV, gas supply & monitoring, 10 Gs LeCroy scope) • Construction materials (e.g. glues, coatings) • GE1/1 DAQ Development • Spare SRS r/o components expected • Dual SRS use for 30cm × 30cm GEMs and for CMS high- GEMs can be anticipated • DATE & AMORE software • CMS Tier-3 Grid Site • Offline data analysis • Can be made available to high- upgrade collaborators for extensive simulation work High-Bay experimental area M. Hohlmann - Florida Tech Statement on Participation in CMS High-eta Muon Upgrade Project

  9. Support Needs • If CMS decides to move forward on MPGD high- upgrade, we would need external support to ramp up our effort. • Potential sources: • USCMS upgrade management for FY11 • Manpower: 1 Post-doc (~6 months), technician • Prototype Production: Materials & Infrastructure • Travel to CERN for test beams • DOE FY11 base funding (starting June 2011) • Manpower: Post-doc, graduate students • Production infrastructure, Readout system • Travel to CERN

More Related