1 / 13

DATE: 1/20/14

NOTE: ALL REPAIR AND RESTORATION WORK REQUIRED IS ABOVE THIS LINE (TYP. FOR ALL PHOTO SHEETS),. Construction Services 170 Long Lane Middletown, CT 06457. EXISTING SLATE ROOF. EXISTING BALUSTRADE W/ COPPER COPING CAP. EXISTING BUILT-IN GUTTERS. EXISTING CORNICE, SOFFIT & FRIEZE. WESLEYAN

Télécharger la présentation

DATE: 1/20/14

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. NOTE:ALL REPAIR AND RESTORATION WORK REQUIRED IS ABOVE THIS LINE (TYP. FOR ALL PHOTO SHEETS), Construction Services 170 Long Lane Middletown, CT 06457 EXISTING SLATE ROOF EXISTING BALUSTRADE W/ COPPER COPING CAP EXISTING BUILT-IN GUTTERS EXISTING CORNICE, SOFFIT & FRIEZE WESLEYAN U N I V E R S I T Y 237 CHURCH STREET SHANKLIN LAB EXTERIOR RESTORATION PROJECT MAJOR MAINTENANCE FY15 WEST ELEVATION DATE: 1/20/14 REVISIONS A-1 NOTE: REFERENCE PROJECT MANUAL DATED 1/20/14 FOR THE BALANCE OF PROJECT REQUIREMENTS & SPECIFICATIONS (THIS NOTE APPLIES TO ALL PHOTO SHEETS). SHEET 1 OF 13

  2. EXISTING BALUSTRADE W/ COPPER COPING CAP EXISTING BUILT-IN GUTTERS (TYP.) Construction Services 170 Long Lane Middletown, CT 06457 EXISTING SLATE ROOF NOTE:ALL REPAIR AND RESTORATION WORK REQUIRED IS ABOVE THIS LINE (TYP. FOR ALL PHOTO SHEETS). EXISTING ARCHED DORMERS WESLEYAN U N I V E R S I T Y EXISTING CORNICE, SOFFIT & FRIEZE 237 CHURCH STREET SHANKLIN LAB EXTERIOR RESTORATION PROJECT MAJOR MAINTENANCE FY15 EXISTING LIMESTONE PILASTER – NO WORK REQUIRED (TYP). DATE: 1/20/14 REVISIONS NORTH / WEST ELEVATION A-2 SHEET 2 OF 13

  3. Construction Services 170 Long Lane Middletown, CT 06457 WESLEYAN U N I V E R S I T Y 237 CHURCH STREET SHANKLIN LAB EXTERIOR RESTORATION PROJECT MAJOR MAINTENANCE FY15 DATE: 1/20/14 REVISIONS A-3 NORTH ELEVATION SHEET 3 OF 13

  4. Construction Services 170 Long Lane Middletown, CT 06457 WESLEYAN U N I V E R S I T Y 237 CHURCH STREET SHANKLIN LAB EXTERIOR RESTORATION PROJECT MAJOR MAINTENANCE FY15 DATE: 1/20/14 REVISIONS A-4 EAST ELEVATION SHEET 4 OF 13

  5. EXISTING SLATE ROOF NOTE:ALL REPAIR AND RESTORATION WORK REQUIRED IS ABOVE THIS LINE (TYP. FOR ALL PHOTO SHEETS). EXISTING BUILT-IN GUTTERS (TYP.) Construction Services 170 Long Lane Middletown, CT 06457 WESLEYAN U N I V E R S I T Y EXISTING ARCHED DORMERS (TYP). EXISTING BALUSTRADE W/ COPPER COPING CAP EXISTING CORNICE, SOFFIT & FRIEZE 237 CHURCH STREET SHANKLIN LAB EXTERIOR RESTORATION PROJECT MAJOR MAINTENANCE FY15 DATE: 1/20/14 REVISIONS SOUTH ELEVATION A-5 SHEET 5 OF 13

  6. Construction Services 170 Long Lane Middletown, CT 06457 WESLEYAN U N I V E R S I T Y 237 CHURCH STREET SHANKLIN LAB EXTERIOR RESTORATION PROJECT MAJOR MAINTENANCE FY15 DATE: 1/20/14 REVISIONS A-6 TYPICAL COPPER CAP WITH COPING JOINT OVER BALUSTRADE TYPICAL BALUSTRADE CLOSE-UP SHOWING COPING JOINT SHEET 6 OF 13

  7. Construction Services 170 Long Lane Middletown, CT 06457 WESLEYAN U N I V E R S I T Y 237 CHURCH STREET SHANKLIN LAB EXTERIOR RESTORATION PROJECT TYPICAL BALUSTRADE CLOSE-UPS - NOTE UNSECURED COPPER FLASHING AT BASE OF BALUSTRADE (REFER TO SCOPE) MAJOR MAINTENANCE FY15 DATE: 1/20/14 REVISIONS A-7 SHEET 7 OF 13

  8. Construction Services 170 Long Lane Middletown, CT 06457 WESLEYAN U N I V E R S I T Y 237 CHURCH STREET SHANKLIN LAB EXTERIOR RESTORATION PROJECT MAJOR MAINTENANCE FY15 DATE: 1/20/14 REVISIONS A-8 TYPICAL CORNICE, SOFFIT & FRIEZE (CAULK BETWEEN LIMESTONE PILASTER AND WOOD FRIEZE BOARD PER SCOPE) TYPICAL ARCHED DORMERS / WINDOW SASH SHEET 8 OF 13

  9. Construction Services 170 Long Lane Middletown, CT 06457 WESLEYAN U N I V E R S I T Y 237 CHURCH STREET SHANKLIN LAB EXTERIOR RESTORATION PROJECT TYPICAL BASE OF BALUSTRADE – SHOWING EXISTING COPPER FLASHING UNSECURED MAJOR MAINTENANCE FY15 DATE: 1/20/14 REVISIONS A-9 TYPICAL CORNICE & FRIEZE SHEET 9 OF 13

  10. Construction Services 170 Long Lane Middletown, CT 06457 WESLEYAN U N I V E R S I T Y 237 CHURCH STREET SHANKLIN LAB EXTERIOR RESTORATION PROJECT TYPICAL BUILT-IN GUTTER MAJOR MAINTENANCE FY15 DATE: 1/20/14 REVISIONS A-10 TYPICAL BUILT-IN GUTTER SHEET 10 OF 13

  11. Construction Services 170 Long Lane Middletown, CT 06457 WESLEYAN U N I V E R S I T Y 237 CHURCH STREET SHANKLIN LAB EXTERIOR RESTORATION PROJECT MAJOR MAINTENANCE FY15 DATE: 1/20/14 REVISIONS A-11 EXISTING BACK SIDE OF BALLUSTRADE SYSTEM - TYPICAL SHEET 11 OF 13

  12. Construction Services 170 Long Lane Middletown, CT 06457 FOR BIDDING PURPOSES, ASSUME THE REPAIR AND REPLACEMENT OF 35 COPPER COPING JOINTS ALONG THE ENTIRE BALUSTRADE COPING COVER PER THE TYPICAL COPING JOINT COVER DETAIL. WESLEYAN U N I V E R S I T Y TYP. COPING JOINT COVER NOTE: ALL DIMENSIONS ON THIS SHEET ARE APPROXIMATE ONLY AND SHALL BE FIELD MEASURED BY THE CONTRACTOR AS REQUIRED. 237 CHURCH STREET SHANKLIN LAB EXTERIOR RESTORATION PROJECT MAJOR MAINTENANCE FY15 DATE: 1/20/14 REVISIONS A-12 BALUSTER ELEVATION PARTIAL WALL SECTION SHEET 12 OF 13

  13. SCOPE OF WORK: • THE PROJECT CONSISTS OF PRIMARILY RESTORATION AND PAINTING OF THE EXISTING CORNICE, SOFFIT, FRIEZE BOARD, BALUSTERS, BALUSTRADE SYSTEM, COPING CAP AND ARCHED DORMER WINDOWS AND TRIM. • THE CONTRACTOR SHALL PROVIDE A FULL-TIME ON THE JOB SUPERVISOR/COORDINATOR AT ALL TIMES DURING THE COURSE OF WORK. • FOR BIDDING PURPOSES, ASSUME EPOXY, DUTCHMEN, CRACKS AND CHECK FILLING REPAIRS FOR ALL BALUSTERS WITHIN THE BALUSTRADE SYSTEM AROUND THE ENTIRE ROOF PERIMETER. PRIME & PAINT UPON COMPLETION OF ALL PREP AND REPAIR WORK. • FOR BIDDING PURPOSES, ASSUME THE REMOVAL AND REPLACEMENT OF ALL FRONT FACE PANELS WITHIN THE BALUSTRADE SYSTEM AROUND THE ENTIRE ROOF PERIMETER, INCLUDING THE FACE PANELS AT ALL FOUR CORNERS. REPLACE WITH EXTERIOR GRADE PLYWOOD TO MATCH EXISTING PANEL THICKNESS. MATCH ALL EXISTING FACE PANEL DETAILS. PROVIDE NEW BLOCKING WITHIN THE EXISTING BALUSTRADE SYSTEM TO ALLOW FOR PROPER FASTENING. SIX SIDE PRIME & PAINT PANELS PRIOR TO INSTALLING. • FOR BIDDING PURPOSES, ASSUME THE REPLACEMENT OF 50 BOARD FEET OF DETERIORATED SOFFIT BOARD. ALSO PROVIDE A UNIT PRICE FOR SOFFIT BOARD REPLACEMENT IN THE DESIGNATED SPACE ON THE BID PROPOSAL FORM. • CONTRACTOR SHALL MAINTAIN THE EXISTING VERTICAL PANEL WOOD STRIPS ON THE BACK SIDE OF THE ENTIRE PERIMETER BALUSTRADE SYSTEM. SCRAPE, PRIME & PAINT. • FOR BIDDING PURPOSES, ASSUME THE REPAIR AND REPLACEMENT OF 35 COPPER COPING JOINTS ALONG THE ENTIRE BALUSTRADE COPING COVER PER THE TYPICAL COPING JOINT COVER DETAIL. • UPON COMPLETION OF ALL PREP WORK AND REPAIRS, CONTRACTOR SHALL PRIME AND PAINT THE EXISTING BALUSTRADE SYSTEM AND COPPER COPING CAP – TYPICAL FOR ENTIRE BUILDING PERIMETER. • CONTRACTOR SHALL PROVIDE A CONTINUOUS COPPER CLEAT TO SECURE THE EXISTING FLASHING ALONG THE BASE OF THE PERIMETER BALUSTRADE SYSTEM. EMBED IN SILICONE SEALANT ALONG THE ENTIRE BALUSTRADE SYSTEM LENGTH (SEE PARTIAL WALL SECTION DETAIL). • CONTRACTOR SHALL PREP, PRIME AND PAINT THE EXISTING SOFFIT, CORNICE AND FRIEZE BOARDS AROUND THE ENTIRE PERIMETER OF BUILDING. CAULK BETWEEN THE TOP OF THE LIMESTONE PILASTER AND BOTTOM OF CORNICE FREEZE BOARD AT EACH CORNER OF THE BUILDING. • CONTRACTOR SHALL PREP, PRIME AND PAINT ALL ARCHED WINDOW DORMER TRIM. ALSO, PREP AND PAINT WINDOW SASHES AND MUNTINS. SPOT GLAZE IF REQUIRED. • CONTRACTOR SHALL REMOVE ALL DEBRIS WITHIN THE EXISTING BUILT-IN GUTTERS. • ADD/ALTERNATE 1: PROVIDE MATERIAL AND LABOR COSTS FOR THE REPLACEMENT OF PERIMETER RUBBER ROOFING THAT TRANSITIONS INTO BUILT-IN GUTTER, METAL FLASHING AND 2 COURSES OF SLATE ROOFING. • HAZARDOUS MATERIAL COORDINATION • ALL PAINTED SURFACES ARE TO BE TREATED AS POSITIVE FOR LEAD CONTAINING PAINT DUE TO THE CONSTRUCTION OF THE BUILDING PRIOR TO 1978. FEDERAL, STATE, LOCAL AND OSHA REQUIREMENTS ARE TO BE STRICTLY ADHERED TO FOR ALL LEAD REMOVAL. CONTRACTOR SHALL WRAP LEAD WASTE IN 6-MIL PLASTIC AND DISPOSE OF IN OWNER SUPPLIED LEAD DUMPSTER. OWNER SHALL DISPOSE OF LEAD WASTE. • ALL CONTRACTOR PERSONNEL WORKING ON THE PROJECT SHALL BE CERTIFIED BY THE U.S. ENVIRONMENTAL PROTECTION AGENCY (EPA) FOR LEAD BASED PAINT ACTIVITIES. • CONTRACTOR SHALL PROVIDE CURRENT BLOOD TEST RESULTS FOR ALL EMPLOYEES WORKING ON WESLEYAN PROPERTIES BEFORE THE START OF ANY WORK. MONTHLY REPORTS SHALL BE PROVIDED THEREAFTER AND ALSO UPON COMPLETION OF THE PROJECT. SEE SECTION 01015. • LOGISTIC NOTES • THE BUILDING WILL BE OCCUPIED AT ALL TIMES DURING CONSTRUCTION. CONTRACTOR SHALL PROVIDE A WORK SCHEDULE TO THE OWNER WEEKLY TO COORDINATE ALL WORK. • CONTRACTOR SHALL ERECT SCAFFOLDING TO PROVIDE SAFE AND SECURE ACCESS TO THE WORK AREAS. MAINTAIN ACCESS TO ALL EGRESS DOORS AT ALL TIMES. PROVIDE SIGNAGE, BARRICADES AND CAUTION TAPE TO DIRECT PEDESTRIAN TRAFFIC INTO AND OUT OF THE BUILDING. • CONTRACTOR SHALL SUBMIT SCAFFOLDING SHOP DRAWINGS TO OWNER FOR REVIEW AND APPROVAL. DRAWINGS SHALL BE STAMPED BY A LICENSED PROFESSIONAL ENGINEER. • CONTRACTOR SHALL PROTECT EXISTING EPDM MEMBRANE AND SLATE ROOF DURING CONSTRUCTION. CONTRACTOR SHALL ALSO PROTECT BALLAST ROOF WHEN WORKING ON SOUTH SIDE OF BUILDING. • CONTRACTOR SHALL CONTAIN LEAD DEBRIS AND DUST IN ACCORDANCE WITH ALL REQUIRED FEDERAL, STATE AND LOCAL LEAD SAFE PRACTICE REQUIREMENTS. CONTRACTOR SHALL USE WET METHODS TO REDUCE THE AMOUNT OF DUST GENERATED. CONTRACTOR SHALL ALSO NOTE THAT WINDOW AIR CONDITIONING UNITS BELOW WORK AREAS WILL BE OPERATING THROUGHOUT THE DURATION OF THE PROJECT AND THE CONTRACTOR SHALL ENSURE THAT NO LEAD DUST OR DEBRIS FALL INTO THE AIR CONDITIONING INTAKES. COMPLETE CONTAINMENT WITHIN THE WORK AREAS IS REQUIRED. • CONTRACTOR SHALL PROTECT EXTERIOR BUILDING FACADE FROM DAMAGE FOR THE DURATION OF THE PROJECT. CONTRACTOR SHALL UTILIZE PROTECTIVE COVERINGS. • CONTRACTOR SHALL COORDINATE THE USE OF MOTORIZED LIFTS AND/OR HEAVY EQUIPMENT WITH THE OWNER. CONTRACTOR SHALL PROTECT EXISTING TURF, CONCRETE WALKS AND PAVEMENT AS REQUIRED.  DAMAGED TURF, CONCRETE WALKS AND PAVEMENT SHALL BE REPAIRED BY THE CONTRACTOR AT NO COST TO THE OWNER. Construction Services 170 Long Lane Middletown, CT 06457 WESLEYAN U N I V E R S I T Y 237 CHURCH STREET SHANKLIN LAB EXTERIOR RESTORATION PROJECT MAJOR MAINTENANCE FY15 DATE: 1/20/14 REVISIONS A-13 SHEET 13 OF 13

More Related