An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Exam Code: H12-425-ENU Exam Name: Huawei Certified Network Professional-Data Center Facility-Build Facility Deployment Optimization Q & A: 237 Q&As Visit more information aboutH12-425-ENUexam: https://www.testpassport.com/HCNP-DCF-BFDO/H12-425- ENU.asp Share some H12-425-ENUquestions and answers below. 1. Which of the following is not part of the NetCol 5000-C30kW precision air conditioner. A. EC fan B. DC inverter compressor C. PID flow regulating valve D. DC fan high efficiency power supply module Answer: B 2.In ECO mode, the UPS operates in the () state when the input is stable. A. Main road inverter B. Bypass C. Battery

  2. D. Maintenance bypass Answer: B 3.When the UPS5000-E (), boot will automatically run the Quick Setup Wizard. (Multiple Choice) A. First boot B. Turn it off and then on. C. The device is turned on again after the factory settings are restored. D. Start after recovery failure Answer: AC 4.When the NetCol5000-A indoor unit and the outdoor unit are not installed separately, the refrigerant line is (). A. Air B. Oxygen C. Nitrogen D. Refrigerant Answer: C 5.The function of the ATS input unit / MCCB input unit of the integrated UPS is (). A. Provide branch output for direct supply from the mains

  3. B. Provide dual or single input to the cabinet C. Provide branch output of UPS direct supply D. Monitor the running status Answer: B 6.The UPS5000-E accepts input voltage frequency in a range of () Hz. A. 40-70 B. 45-70 C. 50-60 D. 55-65 Answer: A 7.The device accesses the ECC800 monitoring system through a smart ETH socket, using the () interface of the intelligent FTH socket. A. PoE B. FE C. RS485 D. AI/DI Answer: A 8.Huawei precision air conditioners support up to () air conditioners to form a group control.

  4. A. 8 B. 16 C. 32 D. 48 Answer: C 9.When the Huawei air-cooled air conditioner outdoor unit is installed horizontally, the distance between the two outdoor units is greater than or equal to () mm. A. 400 B. 800 C. 1200 D. 2000 Answer: C 10.Which mode of air supply is suitable for data centers with high power density in a single cabinet. A. Upper hood B. Under the floor C. Upper air duct D. Row level Answer: D