East Hill Surfers Flow Control Device

East Hill Surfers Flow Control Device. Elegant. Reliable. Precise. And DEAD SEXY. Develo p in g The Desi g n. Define Criteria Generate Choices Pick it out. FCD Criteria. Clogging Resistance Size Reliability Cost. Ease of Use / Maintenance Universality. Prime Desi g n Choices.

roth-orr
Télécharger la présentation

East Hill Surfers Flow Control Device

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. East Hill SurfersFlow Control Device Elegant . . .

  2. Reliable . . .

  3. Precise . . .

  4. And DEAD SEXY.

  5. Developing The Design Define Criteria Generate Choices Pick it out

  6. FCD Criteria Clogging Resistance Size Reliability Cost Ease of Use / Maintenance Universality

  7. Prime Design Choices Variable Torque Bucket Floating Inlet Air Inlet Toilet Float Plug Float

  8. Device Decision Matrix

  9. Conventional Toilet Lever Valve Schematic Inlet Flow F = A γh L1 Float Buoyant Force = FB Pin L2 • Calculations showed that a lever was excessive for given design parameters • A simple float could control the low flow rates without a lever arm to amplify the magnitude

  10. 2 cm 2.3 cm 1.5 cm 2 mm 0.5 cm Rubber tip 4.4 cm PVC stem 11.0 cm 8.3 cm Float mass: 6 grams 6.5 cm 5.2 cm Housing Dimensions: ID = 7.85 cm OD = 8.8 cm Barb tubing adapter 5.6 cm 9.1 cm IV roller clamp IV tubing (~10 drops/mL) 2 mm Simple FloatValve FCD

  11. Testing Apparatus Assembled Prototype Testing Apparatus

  12. FCD Testing Apparatus Water Column Manual Valve 7 kPa Pressure Senor – Logs readings to Easy Data

  13. FCD Performance

  14. Clogging Experiment • Process Controller used to meter water into 10 cm tube. Refilled after head dropped by 40 cm. • Interested in flow rate changes for each 40 cm head drop as well as over several days.

  15. Clogging Data

  16. What We Learned • Low flow presents lots of problems • Complex and simple designs often do the same job • It is easy to overlook valuable solutions • A simple device can have vast implications in the developing world

  17. Further Research • Is there a manufactured device like this already out there? Cost comparison • Cleaning mechanisms • Manufacturing Costs and Opportunities • Material Selection • Maximum head capabilities - Sizing

  18. Steve Achieves Inner Constant Flow