What you have to know about DATE

What you have to know about DATE. Jean-Sebastien Graulich, Geneva. Vocabulary Readout Process Implementing readout code Data Format. Vocabulary. LDC : Local Data Concentrator The PC connected to the VME crate via the PC-VME Interface GDC : Global Data Concentrator Event Builder

rue
Télécharger la présentation

What you have to know about DATE

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. What you have to know about DATE Jean-Sebastien Graulich, Geneva • Vocabulary • Readout Process • Implementing readout code • Data Format Jean-Sébastien Graulich

  2. Vocabulary • LDC : Local Data Concentrator • The PC connected to the VME crate via the PC-VME Interface • GDC : Global Data Concentrator • Event Builder • Event • In this talk, Event = DAQ Event !!! It contains data for several Particle events (~600) • Trigger Receiver • Input Register (with several inputs channels) receiving the signal informing the LDCs that something has happened, e.g the spill is finished and the data should be readout (= DAQ Trigger) • Event Type • Tag attached to the event depending on which input of the trigger receiver has been used. Jean-Sébastien Graulich

  3. Readout Process • Two processes running in each LDC • The readout process waits for a trigger, reads out the front-end electronics, and fills a FIFO with the sub-event data • The recorder process off-loads this FIFO and sends the sub-event data to one or several GDC over the network • Each LDC contains a set of Equipments • Equipment =~ 1 Vme board (in MICE) • Each equipment has its own set of routines for the initialization and readout. • Adding an equipment is done without recompiling all DATE • Equipment configuration data is saved in MYSQL database (but not archived) Jean-Sébastien Graulich

  4. Readout process General algorithm for equipment readout: Jean-Sébastien Graulich

  5. Implementing readout code • 5 user routines (add the equipment name at the end of each routine name) • ArmHw • Executed at the beginning of the Run • Allows initialization of the board • AsynchRead • Executed constantly even if there is no event • Don’t use ! • EventArrived • Used only if the equipment needs to trigger the readout • Used only by the trigger receiver in MICE • ReadEvent • That is the readout itself • DisArmHw • Executed at the end of the Run Jean-Sébastien Graulich

  6. Implementing readout code • Example: Periodic Trigger by Timer typedef struct { long32 *evIntervalPtr; } TimerParType; void ArmTimer( char *parPtr) { // Only passing the configuration parameters from the data base TimerParType *timerPar = (TimerParType *)parPtr; return; } Jean-Sébastien Graulich

  7. Implementing readout code • Example: Periodic Trigger by Timer int EventArrivedTimer( char *parPtr) { /* Returns a value > 0 when a trigger has occured */ /* wait for a trigger in useconds */ TimerParType *timerPar = (TimerParType *)parPtr; if (*timerPar->evIntervalPtr > 0) usleep (*timerPar->evIntervalPtr); return 1; } Jean-Sébastien Graulich

  8. Implementing readout code • Example: Data with Random Size Jean-Sébastien Graulich

  9. Implementing readout code • Example: Data with Random Size int ReadEventRand( char *parPtr, struct eventHeaderStruct *header_ptr, struct equipmentHeaderStruct *eq_header_ptr, int *data_ptr) { /* Called after a trigger has arrived. Inserts header fields data into the area pointed by header_ptr */ /* Inserts raw data into the area pointed by data_ptr. Returns the number of bytes of raw data actually readout.*/ RandParType *randPar = (RandParType *)parPtr; int* firstWord = data_ptr; int dataSize; int i; /* SOB and EOB treatment: no data */ if ( (header_ptr->eventType != PHYSICS_EVENT) && (header_ptr->eventType != CALIBRATION_EVENT) ) { eq_header_ptr->equipmentId = *randPar->eqIdPtr; return ((unsigned long32)data_ptr - (unsigned long32)firstWord ); } /* Physics or calibration data . Set event trigger pattern to a constant value */ SET_TRIGGER_IN_PATTERN (header_ptr->eventTriggerPattern, *randPar->triggerPattern); VALIDATE_TRIGGER_PATTERN (header_ptr->eventTriggerPattern); /* fill the equipment header and the raw data */ eq_header_ptr->equipmentId = *randPar->eqIdPtr; eq_header_ptr->equipmentBasicElementSize = 4; dataSize = (*randPar->eventMinSizePtr + (((float)rand() / RAND_MAX) * (*randPar->eventMaxSizePtr - *randPar->eventMinSizePtr)))/4; for (i = 0; i < dataSize; i++) { *data_ptr++ = i; } return ((unsigned long32) data_ptr - (unsigned long32)firstWord ); } Jean-Sébastien Graulich

  10. Data Format • The data sent by the equipment is just wrapped with a header (+ a second one if GDC is used) • The data format in the payload is defined by the manufacturer of the equipment ! • Date Header format defined in the ${DATE_COMMON_DEFS}/event.h Data from the equipment -> Jean-Sébastien Graulich

  11. Data Format example ======================================================= Size:792 (header:68) Version:0x00030007 Type:PhysicsEvent Subevents:2RunNb:335 nbInRun:2 burstNb:0 nbInBurst:0 ldcId:VOID gdcId:0 time:Fri Jan 26 17:29:05 2007Attributes:Super (00000000.00000000.00000010)triggerPattern:00000003-00000000 detectorPattern:00000000[invalid]...............................................................................Size:372 (header:68) Version:0x00030007 Type:PhysicsEventRunNb:335 nbInRun:2 burstNb:0 nbInBurst:0 ldcId:2 gdcId:0 time:Fri Jan 26 17:29:05 2007Attributes:noAttr (00000000.00000000.00000000)triggerPattern:00000003-00000000 detectorPattern:00000000[invalid] 0) 000001b0 00000001 0000000a 00000000 | .... .... .... .... | 16) 00000000 00000000 00000004 00000000 | .... .... .... .... | 32) 00000001 00000002 00000003 00000004 | .... .... .... .... | ...............................................................................Size:352 (header:68) Version:0x00030007 Type:PhysicsEventRunNb:335 nbInRun:2 burstNb:0 nbInBurst:0 ldcId:1 gdcId:0 time:Fri Jan 26 17:29:05 2007Attributes:noAttr (00000000.00000000.00000000)triggerPattern:00000003-00000000 detectorPattern:00000000[invalid] 0) 0000011c 00000001 00000001 00000000 | .... .... .... .... | 16) 00000000 00000000 00000004 00000000 | .... .... .... .... | GDC Header -> LDC 1 Header -> LDC 1 Payload -> LDC 2 Header -> LDC 2 Payload -> Jean-Sébastien Graulich

  12. Remarks • DATE is running only on 32 bits machines • The test bench in Geneva is not ready yet • We aim at reading data • from VME boards used for MICE • via the MICE VME-PCI Interface • Using the MICE Trigger receiver V797 • With Event Building • We have just managed to install DATE on 2 computers Jean-Sébastien Graulich