1 / 13

NORMAN support for validation of methods at the European level

NORMAN support for validation of methods at the European level. David Schwesig - IWW Water Centre, Germany - Contributors: Biosense, Cemagref, Ineris, ITM, IVM, NPL, RIVO, VUVH, CSIC, UBA, UK-EA. NORMAN Project objectives.

rune
Télécharger la présentation

NORMAN support for validation of methods at the European level

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. NORMAN support for validation of methods at the European level David Schwesig - IWW Water Centre, Germany - Contributors:Biosense, Cemagref, Ineris, ITM, IVM, NPL, RIVO, VUVH, CSIC, UBA, UK-EA NORMAN-CMA Joint Meeting, Paris 21 Oct 2008

  2. NORMAN Project objectives • Creation of a network among European reference laboratories dealing with emerging pollutants • The approach will foster: • co-operation and data transfer of environmental analysis between monitoring institutes, risk assessors and regulatory bodies • validation and harmonisation of monitoring tools • accelerate the availability of reliable & comparable data on emerging pollutants NORMAN – CMA Joint Meeting, Oct 2008

  3. A harmonised approach to validation • has been developed within NORMAN by biological and chemical experts • is not restricted to emerging pollutants • has taken into account existing european and international standards and guidelines wherever possible • E.g. on sampling, terminology, statistics, organisation and evaluation of interlabs/PTs, performance criteria, uncertainty… • is based on a three-level approach • download: www.norman-network.net NORMAN – CMA Joint Meeting, Oct 2008

  4. Why 3 Levels of Validation? • European-wide monitoring is usually not needed in the initial phase of an emerging issue/pollutant  First reports from research, based on internal validation (Level 1) • A potential "emerging issue" may turn out to be either- no problem at all- or only of local importance  Method applicable by a few expert labs sufficient (Level 2) • Large-scale monitoring needed at the European level  Method applicable by routine laboratories and suitable for standardisation (Level 3) NORMAN – CMA Joint Meeting, Oct 2008

  5. Starting point research method(s) available Existing method inappropriate for matrices, compartments or organisms of interest rudimentary internal validation (single lab only) End point: Method appropriate for matrix, compartment or organism of interest e.g. sufficient sensitivity & selectivity complete internal validation no external validation short record of method performance Selection, Adaptation, internal Validation V1: Validation for Research Laboratories NORMAN – CMA Joint Meeting, Oct 2008

  6. Starting point: Appropriate (research) method for matrix, compartment or organism of interest (sufficient sensitivity & selectivity) complete internal validation short record of method performance missing external validation End point: Appropriate expert method with complete internal validation external validation: transferability proven due to poor or unknown robustness: applicable by expert laboratories only Method selection & external validation by „transferability study“ V2: Validation for Expert Laboratories NORMAN – CMA Joint Meeting, Oct 2008

  7. Starting point: appropriate method with complete internal validation external validation incomplete due to poor or unknown robustness: applicable by expert laboratories only End point: fully validated method (internal & external) sufficient robustness to be applicable by routine laboratories high degree of unambiguous documentation (SOP) QA/QC procedures part of method (description) realistic potential for standardisation (CEN) External validation, linkage of QA/QC procedures to the method V3: Validation for Routine Laboratories NORMAN – CMA Joint Meeting, Oct 2008

  8. Chemical methods Biological methods Soil &Sediment Biota Marinesystems Water Air Scope of the validation protocols !Protocols applicable to a wide range of monitoring & biomonitoring methods (chemical & biological) and environmental matrices. NORMAN – CMA Joint Meeting, Oct 2008

  9. Development of protocols for method validation Improvement & Implementation of theValidation Protocols • Case studies („Road-Test“ of the 3 validation protocols) • Oestrogens in wastewaters (level V1) • Non-steroidal anti-inflammatory drugs in waters (level V2) • DecaBDE in dust(levelV3) §§ Development & implementation • „Lobbying“ at CEN level for implementation in standardisation (TC 230) • Implementation at CMA? NORMAN – CMA Joint Meeting, Oct 2008

  10. Implementation - Standardisation • Initiate the implementation of the protocols in the field of European Standardisation • A new work item for a technical guidance document will be proposed to CEN TC 230 (Water Analysis) • This procedure will soon be initiated by a proposal from the project co-ordinator to CEN • If implementation at CEN is sucessful  ISO? • Work under Mandate M424 from DG ENTR to CEN will make use of the NORMAN validation protocols where possible NORMAN – CMA Joint Meeting, Oct 2008

  11. Implementation - CMA • Propose the incorporation of the protocols in guidelines for European monitoring activities • presented to CMA group (14 May 2008) • Reference to the validation protocols integrated in the Guidance Document on Surface Water Monitoring • … NORMAN – CMA Joint Meeting, Oct 2008

  12. Future use of the protocols • Dissemination of the approach by placing a publication in an international (analytical) journal • NORMAN will carry out method validation trials for emerging substances of interest • These studies will follow the NORMAN validation protocols • Interlaboratory studies for method validation on e.g., • pharmaceuticals & hormones • PFC in samples from sewage treatment • Pesticides and their metabolites • Organic phosphorous flame retardants • Siloxanes • For detailed information see Joint Programme of Activitiesfor 2009 / 2010 NORMAN – CMA Joint Meeting, Oct 2008

  13. Summary • Harmonised protocols for method validation have been developed and tested • Protocols will (hopefully) be implemented in the field of European standardisation, and widely accepted • Norman network will work according to these protocols and foster the dissemination of the approach • Step towards a common EU approach for method validation (comparable & reliable data) NORMAN – CMA Joint Meeting, Oct 2008

More Related