EFI Axial Booms Thermal Christopher Smith Thermal Engineer csmith@ssl.berkeley 510-642-2461

EFI Axial Booms Thermal Christopher Smith Thermal Engineer csmith@ssl.berkeley.edu 510-642-2461. Axial Boom Stowed. Axial Boom (AXB) Two units mount inside a carbon fiber tube centrally mounted on the probe Tube attached to the top deck through an aluminum flange that is bare bolted

salali
Télécharger la présentation

EFI Axial Booms Thermal Christopher Smith Thermal Engineer csmith@ssl.berkeley 510-642-2461

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. EFI Axial Booms • Thermal • Christopher Smith • Thermal Engineer • csmith@ssl.berkeley.edu • 510-642-2461

  2. Axial Boom Stowed • Axial Boom (AXB) • Two units mount inside a carbon fiber tube centrally mounted on the probe • Tube attached to the top deck through an aluminum flange that is bare bolted • Bare bolted to lower deck • Two stacers, one from each unit, deploy out the tube ends AXB Mounting Tube Single AXB unit

  3. AXB a/e Map • 80% Alum Foil Tape • 20% Bare Carbon Fiber VDA Tape Alodined Aluminum Bare Carbon Fiber

  4. AXB Model Inputs • Optical materials • Aluminum Foil Tape • Bare Carbon Fiber • Alodined Aluminum • Thermophysical materials • Aluminum, 6061 • K13D2U Carbon Fiber • T300 Carbon Fiber • Heaters • None used at this time, though we are prepared to supply deployment heaters if needed • Conductors • Bare bolted top flange to deck: 0.612 W/C inc. bolts, flange, and adhesive • Bare bolted bottom flange to deck: 3.3 W/C each, 20 W/C total • Bare bolted AXB to Tube mount: 0.79 W/C each, 0.476 total • Power Dissipation • 0 Watts AXB Mounting Tab

  5. AXB Case sets • Bottom to sun a cold case boundary condition has no eclipse • All above cases run separately with stowed boom and deployed boom

  6. AXB Mechanical Unit Standard Plots - Deployed

  7. AXB Mechanical Unit Sunline Plots - Deployed

  8. AXB Mechanical Unit Standard Plots - Stowed

  9. AXB Mechanical Unit Sunline Plots - Stowed

  10. AXB Results Table

  11. AXB Mounting Tube Modifications • Spacecraft was consuming too much power in the coldest, but nominal, science case ~2.2 W • To help mitigate this issue two modifications are being considered for the AXB Mounting tube • Tube construction switched from all T300 ( 5 W/mK) fiber to 4 plys K13D2U (500 W/mK) + 2 plys T300 • Tube exterior changed from blanket to a mix of Foil tape and bare carbon • Current results show the AXB unit getting too hot and we are currently exploring options to cool it down • Increase isolation between AXBs and tube • Isolate tube flange from top deck • At worst, cool the tube down by reducing the percentage of foil tape • When the design is complete it will be within limits though new temperatures may require the thermal vac hot deploy test be repeated at a new higher temperature

  12. AXB Temp Map for Hottest Case

  13. AXB Temp Map for Coldest Case

  14. Axial Boom Deployed AXB “can” AXB PreAmp Exposed Bit After Deploy

  15. AXB Geometry Model • Deployed Stacer Model

  16. AXB Deployed Elements a/e Map • DAG 154 Alodined Aluminum DAG 213 Bronze

  17. AXB Model Inputs • Optical materials • Acheson Coloids DAG 213 (2 part) • Acheson Coloids DAG 154 • Alodined Aluminum • Bronze • Thermophysical materials • Aluminum, 6061 • Bronze • Elgiloy • PEEK • Heaters • None • Conductors • Main Stacer to Tip Piece, 1 rivet and circumferential contact, .3 < G <.9 W/C • Tip Piece To Bronze DDAD Lock, Large threaded interface, 10 W/C • DDAD Lock to PreAmp, large threaded bolt 3.57 W/C • PreAmp to Mini Stacer, 1 rivet and circumferential contact .3< G <.8 W/C • Mini Stacer to Can, 1 rivet, 0.3 W/C • Power Dissipation • 0.07 Watts Nominal at Preamp AXB Preamp

  18. AXB Deployed Elements Case Sets • Top and Bottom to sun cases after deployment are limited to no less than 11 degrees off the sun line • The Model for the Top and Bottom to Sun cases goes through a 180 min eclipse. A 100 min eclipse is the actual limit and is shown in plots

  19. AXB Boom Elements Standard Plots - Deployed

  20. AXB Boom Elements Sunline Plots - Deployed

  21. AXB Preamp Results Table • Science operation limited to a 36 min eclipse • Current predicts show Preamp falling below the limit on the TO99 can.

  22. AXB Preamp Qualification • AXB Preamp model is currently a simple lump with the proper radiative surfaces • Thermal isolation of the TO-99 from the outer shell is complicated and difficult to reliably model • Thermal Vacuum test planned determine the thermal isolation of the TO-99 from the preamp outer surface (April 12th – April 23rd) • This thermal isolation determined by test will be input into the thermal model to determine a reliable qualification temperature, still likely to be under the current qualified temp of –65

  23. AXB Preamp Models

  24. EFI Spin Plane Booms • Thermal • Christopher Smith • Thermal Engineer • csmith@ssl.berkeley.edu • 510-642-2461

  25. SPB • 4 separate units mounted to the bottom deck • Snout pokes out the solar panel • Sphere and Preamp deploy out the snout on a wire (Half Sphere shown in picture) • Sphere and preamp separate as rotation unwinds a thin wire from a spring loaded wheel

  26. SPB a/e Map • AZ 2000 IECW Inorganic White Paint Alodined Aluminum MLI

  27. SPB Model Inputs • Optical materials • Germanium Black Kapton (Sheldahl 275XC Black Kapton) • Alodined Aluminum • AZ 2000 IECW Inorganic White Paint • Blanket: .01 < e < .05 • Thermophysical materials • Aluminum, 6061 • ULTEM • Heaters • None used at this time, though we are prepared to supply deployment heaters if needed • Conductors • 1/8” Ultem isolators for top deck: 0.01 W/C each, 0.04 W/C total • Power Dissipation • 0 Watts

  28. SPB Case Sets

  29. SPB Mechanical Unit Standard Plots

  30. SPB Mechanical Unit Sunline Plots

  31. SPB Results Table

  32. SPB Heat Map for Coldest Case

  33. SPB Heat Map for Hottest Case

  34. SPB Deployed Elements • Preamp and sphere are connected by a thin wire • Preamp is connected to SPB deployment unit by another wire • Preamp is nearly identical to Axial version • Sphere is only a mechanical element Titanium Nitride DAG 213

  35. Preamp and Sphere Analysis

  36. SPB Sphere and Preamp Model • Nodes 3 and 4 are for the sphere hot and cold cases • Nodes 5 and 6 are for the preamp hot and cold cases • As with the axial preamp the SPB preamp falls below its limit by a bit. Qualification plan is in the works

  37. SPB Sphere and Preamp Plot