1 / 7

EL SCADA Components Rad Tests

EL SCADA Components Rad Tests. EL SCADA components Radiation R esistance Tests Typical US/RE system components. EL SCADA Components Rad Tests. Typical US/RE installation: RTU: CLP500E EFACEC Advantech Diskless board Power Supply module, 48VDC Supply DAU, 48VDC Supply

Télécharger la présentation

EL SCADA Components Rad Tests

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. EL SCADA Components Rad Tests EL SCADA components Radiation Resistance Tests Typical US/RE system components

  2. EL SCADA Components Rad Tests • Typical US/RE installation: • RTU: CLP500E EFACEC • Advantech Diskless board • Power Supply module, 48VDC Supply • DAU, 48VDC Supply • CPU/Communication: MAP3200 Prometheus • Input MAP3020, Output MAP3050 • Analogues MAP3080 • IED,DIRIS Ap, 48VDC Supply (Low Voltage Switchboards) • Adapters, 24VDC Supply • ADAM 4520: RS232/RS485 • Switch MOXA EDS308 • ELECDAN Power Converter 48/24VDC • ELECDAN Pt100/10V Converter • ELECDAN Counter/10V Converter (Ackerman Battery Measurement) • Acquisition of Voltage Relay

  3. EL SCADA Components Rad Tests • Monitoring: • Remote Desktop Connection to connect to RTU • CLP500 Version 5.1.0 managing the system • Daily Control execution in List Mode • Automatism (Fung function) • Return on Input board makes events & Alarm • Reaction in case of failure (SEE) • Remote Reboot • RTU level (if RDC & ping failure) • DAU level (if IEC-Down & Win 3200 failure) • 24VDC convertor (Switch, ADAM4520, ELECDAN convertors) • DIRIS module (if Communication or measurements lost)

  4. Ethernet GPN Remote Desktop Connexion RR RTU CLP500E RR RR Switch SPHINX EDS308 Win3200/RS232 ADAM 4520 RS232/RS485 ELECDAN Converter 48/24VDC RR 870-5-104/TCP/IP Remote Reboot Jbus/RS485 DAU MAP3200 MAP3020/50/80 24VDC ELECDAN Counters RT ELECDAN Pt100 Power Supply 230/48VDC 6Amp 48VDC DIRIS Ap 230VAC

  5. Ethernet GPN Remote Desktop Connexion RTU CLP500E RTU CLP500E RTU CLP500E Remote Reboot RR RR RR RR RR RR RR RR RR Converter 48/24VDC Converter 48/24VDC Converter 48/24VDC ADAM 4520 ADAM 4520 ADAM 4520 RR RR RR 870-5-104/TCP/IP 870-5-104/TCP/IP 870-5-104/TCP/IP Switch SPHINX EDS308 Switch SPHINX EDS308 Switch SPHINX EDS308 Win3200/RS232 Win3200/RS232 Win3200/RS232 DAU MAP3200 MAP3020/50/80 DAU MAP3200 MAP3020/50/80 DAU MAP3200 MAP3020/50/80 Jbus/RS485 Jbus/RS485 Jbus/RS485 RT RT RT ADAM4080 & Pt100 ADAM4080 & Pt100 ADAM4080 & Pt100 ELECDAN Counters ELECDAN Counters ELECDAN Counters DIRIS Ap DIRIS Ap DIRIS Ap 48VDC Power Supply 230/48VDC 6Amp 230VAC

  6. EL SCADA Components Rad Tests • Mechanical design • No extra shielding,Light rack mounting • Statistics • 3 systems in // • Permanent monitoring • Human daily check • Costs • Components: 20kCHF • Work: 10kCHF • Conditions • Activated material • Not repairable • Not re-usable • Schedule • CNGS TSG46 • Time slot to be defined Rack Front view Rack Back view