1 / 11

Alex Sushkov Dima Budker Valeriy Yashchuk (UC Berkeley)

Kerr Effect-based Measurement of the Electric Field. Alex Sushkov Dima Budker Valeriy Yashchuk (UC Berkeley). Kerr Effect. Kerr effect : appearance of birefringence in an initially isotropic medium, induced by an applied external electric field:  n = n || -n  = KE 2

saxon
Télécharger la présentation

Alex Sushkov Dima Budker Valeriy Yashchuk (UC Berkeley)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Kerr Effect-based Measurement of the Electric Field Alex Sushkov Dima Budker Valeriy Yashchuk (UC Berkeley)

  2. Kerr Effect • Kerr effect: appearance of birefringence in an initially isotropic medium, induced by an applied external electric field:n = n||-n= KE2 • For input light polarized at 45o to E, the induced ellipticity: = Ln/ = (L/)KE2 • K is related to hyperpolarizability  :P = E +  E3/6 + …

  3. Why do it? • Measure the magnitude of an electric field. • Measure the spatial and temporal dependence of an electric field. • Investigate the structure of liquid helium: - pair and higher correlations of atoms in the liquid, - Kerr virial coefficients, - effect of temperature and superfluidity.

  4. Experimental Setup ArXiv: physics/0403143

  5. Some apparatus details • Cryogenics: Janis pumped helium cryostat with optical access, Tmin = 1.5 K. • High-voltage cables: carbon steel wire insulated with teflon heat-shrink. • Breakdown in LHe: - breakdown in LHeII at 70 kV/cm - no breakdown in LHeI observed up to 130 kV/cm. • Polarimeter: - 785 nm diode laser, - electro-optic modulator, - lock-in detection at 50 kHz, - room-T sensitivity 10-7 rad/Hz1/2.

  6. Results: LN2 • Measured Kerr constant for LN2 at 73 K:K = (4.380.15)10-18 (cm/V)2 • Published value:(K.Imai et. al., Proceedings of the 3rd Int. Conf. On Prop. and App. Of Diel. Mat., 1991 Japan)K = 4.310-18 (cm/V)2 (no error given)

  7. Results: LHe Measured Kerr constant for LHe at 1.5 K: K = (1.43 0.02(stat) 0.04(sys))10-20 (cm/V)2

  8. T-dependence: LHe Within the experimental error, the LHe Kerr constant does not depend on temperature in the range 1.5 K to 2.2 K.

  9. Superfluidity: absence of temperature dependence means that superfluidity does not affect the Kerr constant of LHe. He atom hyperpolarizability: = (44.20.8) atomic units (Tammer et al.) KLHe  (1.100.02)10-20 (cm/V)2 Van der Waals complexes:polarizability anisotropy of complexes of two or more He atoms contribute 23% to KLHe. Theoretical interpretation

  10. Measuring the electric field in the neutron EDM experiment • Electric field requirements: • E = 50 kV/cm. • 1% uniformity over the cell volume. • < 1% drift over 500 seconds. • diagnostics for the HV test set-up. • Signal to be measured: assuming sample length L = 30 cm, the Kerr ellipticity is  210-5rad. • Sensitivity: with sensitivity 10-7 rad/Hz1/2, we get E/E  510-3 in a 1 second measurement. • Challenge:achieve this sensitivity at 300mK.

  11. A cold magnetometer • Goal:shot-noise limited sensitivity ofB ~310-13 Gauss/Hz1/2