1 / 11

Evaluator-Reminders 6/07 Jagdish Tuli* National Nuclear Data Center

Evaluator-Reminders 6/07 Jagdish Tuli* National Nuclear Data Center Brookhaven National Laboratory *Email: Tuli@bnl.gov. Brookhaven Science Associates. Adopted Properties Q-record – must be given -even if nothing known

shay
Télécharger la présentation

Evaluator-Reminders 6/07 Jagdish Tuli* National Nuclear Data Center

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Evaluator-Reminders 6/07 Jagdish Tuli* National Nuclear Data Center Brookhaven National Laboratory *Email: Tuli@bnl.gov Brookhaven Science Associates

  2. Adopted Properties Q-record – must be given -even if nothing known Values from Audi masses, explanation if from other source, give Audi values for comparison Give Systematic uncertainties as comments. Reminders-Adopted

  3. Adopted Properties XREF even if only one data set with gammas BAND Identification only on first record Reminders-Adopted

  4. Adopted Properties Levels: GS and Isomers: Decay Modes and moments must be given, if known, on the continuation records. Any comments on these should be on the comment records only. T1/2 from keyno. Is not enough, include DSID Moments – Check Stone’s compilation (2005St25) Isomer is a level with T1/2>=0.1 S or if it has an IT dataset Reminders-Adopted

  5. Quote authors’ measured quantities Document any deviations Note authors’ assumptions Check for missed references Check authors’ quoted older values Reminders-extraction of data

  6. Order of Comments E= not needed for reaction Target JPI should be given Keyno: measured, etc. Do not combine different kind of data sets Specify source of data Ensure accuracy of values from adopted set Do not say “from ENSDF” Reminders-presentation of data-1

  7. Gammas order by increasing Eg Significant digits Uncertainty limited to 25 Multiplets Xsection,Analyzing-power not given A2, A4, DCO ratios given with definition Reminders-presentation-2

  8. BEL up for levels, down for gammas. Program modified Delayed gammas - give as IT decay, ex 140Dy Reminders-presentation-3

  9. Normalization condition should be given Parent record, all fields should be given Replace `/’ by `:’ for multiple ratios Unresolved discrepancies should be pointed out Uncertainty not error E(ec),E(b-) only when accurate, measured XUNDL data helpful but evaluator responsibility Reminders-presentation-4

  10. LogT1/2(alpha) vs Log E(alpha) is linear Takahashi’s gross beta decay theory reliable to better than a factor of 3 Alpha Decay HF Certain pairs of conf lead to isomeric transitions GS feeding from local systematics Mass syst from Audi Reminders-Systematics

  11. APS style adopted Accepted abbreviations Key no. is plural. Space after `,’ etc. Reminders-Style

More Related