News about QDO short Prototype magnetic measurements (Dec 2011/Jan 2012) C.Petrone , J.Garcia Perez, A. Vorozhtsov , M. Modena. “CLIC MDI Meeting” on 27/01/2012 . The “Single Stretched Wire” and “Rotated Vibrating Wire” MM System.

shilah
Télécharger la présentation

“CLIC MDI Meeting” on 27/01/2012

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. News about QDO short Prototype magnetic measurements (Dec 2011/Jan 2012)C.Petrone, J.Garcia Perez, A. Vorozhtsov, M. Modena “CLIC MDI Meeting” on 27/01/2012

  2. The “Single Stretched Wire” and “Rotated Vibrating Wire” MM System “CLIC MDI Meeting” on 27/01/2012, M. Modena

  3. The “Rotated Vibrating Wire” MM System: some basic concepts taken from a recent presentation at IMMW17 (“17th International Magnetic Measurement Workshop”) “CLIC MDI Meeting” on 27/01/2012, M. Modena

  4. The “Rotated Vibrating Wire” MM System “CLIC MDI Meeting” on 27/01/2012, M. Modena

  5. The “Rotated Vibrating Wire” MM System “CLIC MDI Meeting” on 27/01/2012, M. Modena

  6. The “Rotated Vibrating Wire” MM System “CLIC MDI Meeting” on 27/01/2012, M. Modena

  7. The “Rotated Vibrating Wire” MM System “CLIC MDI Meeting” on 27/01/2012, M. Modena

  8. The “Rotated Vibrating Wire” MM System “CLIC MDI Meeting” on 27/01/2012, M. Modena

  9. …about our QD0 measurements: “CLIC MDI Meeting” on 27/01/2012, M. Modena

  10. CLIC QD0 magnet prototype (with permanent magnet blocks in Nd2Fe14B): 1st measurement with SSW and RVW systems versus calculations Fig2: Magnet cycle (ramp-up to Imax and ramp-down). Fig1- Table1: Magnet excitation curve vs. computed values. “CLIC MDI Meeting” on 27/01/2012, M. Modena

  11. CLIC QD0 magnet prototype (with permanent magnet blocks in Nd2Fe14B): 1st measurement with SSW and RVW systems versus calculations Fig1- Table1: Measured (SCALED at R=1 mm) integrated field components (from measurement done at R=3 mm). Magnetic axis stability: Between the measurement at different current (ramps) it was not necessary to re-align the magnetic axis; this means that the drifting of the magnetic axis vs. current is inside a range of ~5 μm . “CLIC MDI Meeting” on 27/01/2012, M. Modena

  12. thanks! “CLIC MDI Meeting” on 27/01/2012, M. Modena

  13. … what I presented at last MDI Meeting (on 1st measurement of 28 Nov. 2011): • (NOTE: These results are PRELIMINARY!) • A second MM run is ongoing n tese days. Magntic Filed components are also under evaluation with Vibrating SSW • They promise me (as a “Christmas Gift”) a more official and complete measurements report for next week. • - Magnet will be then also measured with Rotating Coil system. • First analysis: • Confirmed validity of the design. • Some missing performance to be understood (we have some ideas about this). “CLIC MDI Meeting” on 16/12/2011, M. Modena