An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Experimental and Numerical Study of Mist Cooling for the Electra HibachiV.Novak, D.Sadowski, S.Shin, K.Schoonover, and S. Abdel-Khalik HAPL meeting, Madison, WI (September, 24-25, 2003) G. W. Woodruff School of Mechanical Engineering Atlanta, GA 30332–0405 USA

  2. Diode (vacuum) Laser Gas 1.3-2.0 atm (Kr+F2) flow at 4 m/s E-beam Hibachi Foils Hibachi Ribs He(or Air)/ Water mix Water Layers Pressure Foil Anode Foil LASER GAS VACUUM EMITTER E-beam Objectives • Experimentally examine effectiveness of gas/liquid mist as a means of cooling the Electra Hibachi Foils • Quantify effect of various operating parameters on mist cooling effectiveness for prototypical Hibachi geometry (gas/liquid combination, gas velocity, liquid mass fraction, droplet size) • Develop a validated mechanistic model to predict Hibachi foils’ thermal response under prototypical pulsed operating conditions

  3. Experimental Setup

  4. Experimental ResultsAir/Water Mist Cooling – Rectangluar Channel (24 cm) Air-Assisted Nozzle Average heat transfer coefficient [W/m2K] Average enhancement ratio [h/hdry air] 15m/s 15m/s Ultrasonic Nozzle 10m/s Average heat transfer coefficient [W/m2K] 10m/s 5m/s 5m/s 15m/s Water inlet mass fraction [%] Water inlet mass fraction [%] 10m/s Local heat transfer coefficient [W/m2K] Average heat transfer coefficient [W/m2K] 5m/s 15m/s,15% 15m/s,10% water inlet mass fraction [%] 15m/s,5% Optimization of atomizing air mass fraction (10m/s air,10% water) Max Twall=80-90oC 15m/s,dry air Air-assisted nozzle inlet pressure [psi] Axial distance [cm]

  5. Air/Water Mist Flow [100% Saturation] (Tin=20 oC, 1 atm, rp=30 m) Coolant Distribution Particle Distribution foils (Hastelloy-X =0.25 mm) Coolant Temperature Front Surface Temperature Back Surface Temperature Particle Temperature 2 cm 6 cm Heating (Qw) 60 cm Heating (Qw) insulated side wall 4 cm Numerical Simulation steady state experiment (Air/Water)

  6. Coolant Exit Temperature 0 % water 4 % water 5 % water 10 % water 15 % water dry air (15m/s, Qw=250W) Numerical Simulation steady state experiment (Air/Water) Coolant Bulk Temperature Wall and Coolant Temperature Distribution Pressure P [kPa] T [K] Solid line : Coolant bulk temperature Dash dot line : Wall temperature z [cm] z [cm] Heat transfer coefficient at the wall 15m/s Air Qw=250W rp=30 m Wall film thickness

  7. Coolant Exit Temperature Wall and Coolant Temperature Distribution Solid line : Coolant bulk temperature Dash dot line : Wall temperature T [K] 0 % water 16.7 % water 33.5 % water 50.2 % water dry Helium (30m/s, Qw=250W) Numerical Simulation steady state experiment (Helium/Water) Coolant Bulk Temperature Pressure P [kPa] T [K] z [cm] z [cm] Heat transfer coefficient at the wall 30m/s Helium Qw=250W rp=30 m

  8. Coolant Distribution Particle Distribution Air/Water Mist Flow [0% Saturation] (15m/s Air, 10% Water Tin=20 oC, 1 atm, rp=30m) foils (Titanium, =0.025mm) Coolant Temperature Front Surface Temperature Back Surface Temperature 2 cm Particle Temperature Heating 30 cm Heating Q [W/cm3] 0.1ms insulated side wall 587250 W/cm3 0.1 s time [sec] 0 pulse start at 4.0 s 4 cm Numerical Simulation pulsed heating (10Hz)

  9. Numerical Simulation pulsed heating (10Hz) Coolant Exit Temperature Maximum Temperature at the wall Dry Air Dry Air Air/Water (15m/s, 15%) Air/Water (15m/s, 15%)

  10. A B C t [sec] Numerical Simulation pulsed heating (10Hz) Coolant Temperature Distribution Surface Temperature Distribution Heat Transfer Coefficient Distribution Dry Air Air/Water A : just before pulse B : just after pulse C : one pulse later (15m/s,15%)

  11. Conclusions • Mist cooling provides the means to effectively cool the Electra Hibachi within specified constraints on cooling system power consumption, foil max temperature, and temperature gradient • Heat transfer coefficient can be significantly increased especially for prototypical transient condition • A validated mechanistic model to predict the foils’ thermal response under prototypical conditions has been developed

  12. Future Efforts • Examine effect of liquid film formation on e-beam transmission efficiency • Examine system performance for other gas/liquid combinations • Construct and test a multi-channel test module under prototypical conditions