1 / 27

DPA UPScale TM RACK Mountable & Modular Continuous Power Protection Availability

DPA.UPScaleTM is a rack-mountable and modular UPS system that provides continuous power protection. With its decentralized parallel architecture and true online transformerless topology, it offers high availability, energy savings, and environmental friendliness. The safe-swap modular architecture allows for easy scalability and fault recovery.

smays
Télécharger la présentation

DPA UPScale TM RACK Mountable & Modular Continuous Power Protection Availability

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. DPA UPScaleTM RACK Mountable & ModularContinuous Power Protection Availability The multimaster technology – DPA UPScale

  2. DPA UPScaleTM ST and RI DPA UPScale RI DPA UPScale ST Rack Indipendent (RI) RI 10-80 kW up to 4 Modules Standard (ST) ST 10 – 120 kW up to 6 Modules DPA UPScale

  3. TCO 20kW Energy Saving 20kW Environmental Friendly 20kW Modular – Rack -Mountable 20kW Decentralized Parallel Architecture 20kW True On-line Transformerless - Topology 20kW The Fundamental Pylons of DPA UPScale DPA UPScaleTMST 120 kW DPA UPScale

  4. DPA UPScaleTM: Essential questions : • Is a double conversion , true on-line UPS essential for you? • Is a decentralized UPS control important for you? • Is a small or smallest foot print important for you? • Is efficiency important to you? • Is future power expansion without extra installation important for you? DPA UPScale

  5. DPA UPScaleTM: Essential questions : • Is the module and UPS weight an important feature for you ? • Do you appreciate having individual displays for each module ? • Is it a benefit for you having just one person (instead of two) to replace or add a module ? • Is front access compulsary ? DPA UPScale

  6. DPA UPScaleTM: Essential questions : • Having flexible battery block no. for better sizing of autonomy times. Is this important for you ? • Having a separate battery for each individual module increases the overall availability as opposed to a common battery. Is this important for you ? • Having a variety of cabinets increases the flexibility of choice. Is this a benefit for you ? • How important is the efficiency and TCO for you ? DPA UPScale

  7. True On-line Transformerless - Topology Normal Operation • Full double conversion Technolgy • Transformerless ; Totel Efficiency up to 95.5 % • Output DC offsets full under control through EDCP • Highest output performance • Lowest Input distortion through IGBT Booster/Rectifier DPA UPScale

  8. Decentralized Parallel Architecture DPA Decentralized Parallel Architecture (DPA)TM from NEWAVE Decentralized Parallel Architecture (DPA)TM was designed to distribute virtually the entire UPS Hardware and Software into modules in order to reduce the Single Points of Failures (SPOF). DPA includes distributed MAINS 2 MAINS 1 • Control Panel on Module DPA CONTROL PANNEL DPA CENTRAL PROCESSING UNIT DPA POWER UNIT DPA STATIC BP SWITCH • CPU • Power Unit DPA BATTERY PACKS • Static bypass switch DPA CONTROL PANNEL DPA CENTRAL PROCESSING UNIT DPA POWER UNIT DPA STATIC BP SWITCH and • Separate Batteries DPA BATTERY PACKS DPA CONTROL PANNEL DPA CENTRAL PROCESSING UNIT DPA POWER UNIT DPA STATIC BP SWITCH DPA BATTERY PACKS CRITICAL LOAD DPA UPScale

  9. Decentralized Parallel Architecture DPA DPA UPScaleTM HIGHLIGHTS and Benefits • High level of decentralization • Multi Master and Slave Technology through a simplified BUS Communication • Full redundancy on inverter • Full redundency on Static Bypass Switch (SBS) DPA UPScale

  10. 0.99 0.99 0.985 0.96 Input PF (%) Load %) DPA UPScaleTM / Environmental Friendly Reduced TCO Input Power Factor versus load Advanced Booster PFC circuit to provide near-unity Input PF even with partial loads. • Benefits: • No phase compensation filter required • Respect power grid regulations • Energy savings DPA UPScale

  11. 3.4 3.0 2.7 2.5 THD I(%) Load (%) DPA UPScaleTM / Environmental Friendly Reduced TCO Input THDi versus load Advanced Booster PFC circuit to provide Flat THDI Curve even with partial loads. • Benefits: • No gen-set oversized required • Small cable/fuses/breakers size • No extra heating of transformers UNIQUE ELECTRICAL PERFORMANCE DPA UPScale

  12. Other Modular UPS efficiency DPA UPScaleTM / Energy Saving Reduced TCO Flat Efficiency graph Results in low losses at PARTIAL and FULL load. Redundant UPS Systems operate typically at 25-75% of the rated load. Energy Saving… 97 95.5 95.5 96 95 94.5 95 Efficiency (%) 94 93 92 91 90 25% 50% 75% 100% Load (%) DPA UPScale

  13. Highlights • Safe-Swap Modules • High Availability • Enhanced Serviceability • Flexibility / Scalability • Low Cost of Ownership thanks to right sizing • Lowest Module weight in its class • Blade Server Friendly Power/Leading loads • High Power Density • Reduced Footprint DPA UPScale

  14. Safe-Swap Modular Architecture Safe-swap, is a term used to refer to hot insertion and removal of modules from a host system without removing power. In a redundant Power Protection System Safe-swap is achieved only if a faulty module may be replaced without interrupting the power to the load (application) and w/o having to transfer the load (application) to the raw mains (by-pass). Employing appropriate hot swap techniques highly available power protection systems with ease of scaling and easy fault recovery can be created. DPA UPScale

  15. Safe-Swap modules The DPA UPScaleTM Modules are fully independent and are composed of all major hardware and firmware building blocks: • CPU (Central Processing Unit) • All power circuits (rectifier, inverter, battery charger) • Static switch and static switch control • Power Management Control Panel In-built Display Static Switch Control unitDisplay Rectifier Booster Inverter Battery DPA UPScale

  16. MTBF MTTR High Availability To achieve near-zero downtime and avoid very costly consequences of disruption of Mission Critical Applications, advanced Modular Power Protection Architectures with High Availability must be employed. High Availability Double Conversion TopologyClass VFI-SS–111 Fault ToleranceRedundancy Rapid Recovery Modularity DPA UPScale

  17. Enhanced Serviceability • Safe-Swap Modular design, minimize service and maintenance costs • One person can easaly exchange the low weight modules • MTTR reduction maximize your power protection availability • No need of skilled personnel on site • Non need of spares, only modules for an easy fault recovery DPA UPScale

  18. 10kW / 10kVA 20kW / 20kVA DPA UPScaleTM Power Range 10-120 kW 2 module 3 modules 4 modules 6 modules UPScale ST 40 UPScale ST 60 UPScale ST 120 UPScale ST 80 19” UPScale Modules : UPScale M10 UPScale M20 HU = 3 WxHxD 488x132x488 18.3 kg and 21.5 kg WxHxD 550x1135x767 WxHxD 550x1975x757 WxHxD 550x1135x767 WxHxD 550x1975x767 External Batt. ONLY 2 x 40 x 7.2/9AhTotal 80 blocks External Batt. ONLY 3 x (2x40) x 7.2/9AhTotal 240 blocks DPA UPScale

  19. 10kW / 10kVA 20kW / 20kVA DPA UPScaleTM RI 10-80 kW Rack-Independent Models UPScale RI 11 UPScale RI 12 UPScale RI 10 19” UPScale Modules : UPScale M10 UPScale M20 HU = 3 WxHxD 488x132x488 18.3 kg and 21.5 kg WxHxD 488x665x732(15HU) WxHxD 488x487x732 (11Hu) WxHxD 488x487x732 (11Hu) 1 x 40 x 7.2/9AhTotal 40 blocks No internal Batteries 2x40 x 7.2/9AhTotal 80 blocks DPA UPScale

  20. 10kW / 10kVA 20kW / 20kVA DPA UPScaleTM RI 10-80 kW Rack-Independent Models UPScale RI 40 UPScale RI 20 UPScale RI 24 UPScale RI 22 19” UPScale Modules : UPScale M10 UPScale M20 HU = 3 WxHxD 488x132x488 18.3 kg and 21.5 kg WxHxD 488x665x732(15HU) WxHxD 488x798x732(18HU) WxHxD 488x1153x732(26HU) WxHxD 488x798x732(18HU) 2x40 x 7.2/9AhTotal 80 blocks 4x40 x 7.2/9AhTotal 160 blocks No internal Battery No internal Battery DPA UPScale

  21. WITH MODULARDESIGN, WASTED ENERGY DURING YEARS IS REDUCED ! 1 0 20kW Module 20kW Module 20kW Module 20kW Module 20kW Module 20kW Module 40 kW 40kW 40kW 40 kW Rightsizing Over Time 160 kW 140 kW 120 kW 100 kW Power [kVA] 80 kW Load Curve 60 kW 40 kW 20 kW Modular Configuration Year 0 1 2 3 4 5 6 Pay as you grow… without any change of installation Exp. Critical Load = 100kW Expected Critical Load = max 100 kW DPA UPScale

  22. Blade Server Frinedly Power Blade Servers have leading Power Factors and therefore require adequate power from UPS DPA UPScale provides full rated power in KW @ cosphi 1 or constant KVA rating from - 0.90 lead. to 0.60 lag. 25 1.00 - 0.90 1.00 0.80 - 0.80 0.80 20 Power (kW versus KVA) Additional kW 15 10 Constant kW No UPS oversize required 5 0 -0.75 -0.80 -0.85 -0.90 -0.95 1.00 0.95 0.90 0.85 0.80 0.75 0.70 0.65 DPA UPScale

  23. Features: DPA UPScale ST 10-120 kW • DPA with Safe-Swap Modules (SSM) • Exceptionally low Module weight • Safe Swap extendable from 10-120kW (max. 6 Modules) • Flexible battery management blocks • Ripple free through battery charger • Distributed control and power • LCD display integrated on Module • Low Total Cost of Ownership (TCO) • Huge Flexibility / Scalability • Easy to install and service • Excellent Input PFC: >0.99 @ 100% load • Low input THDI: < 3% @ 100% load • High conversion efficiency: up to 95.5% DPA UPScale

  24. Features: DPA UPScale RI 10-80 kW • Integratable in any 19” rack • DPA with Safe-Swap Modules (SSM) • Exceptionally low Module weight • Safe Swap extendable from 10-80 kW (4 Modules) • Flexible battery management blocks • Ripple free through battery charger • Distributed control and power • LCD display integrated on Module • Huge Flexibility / Scalability • Easy to install and service • Excellent Input PFC: >0.99 @ 100% load • Low input THDI: < 3% @ 100% load • High conversion efficiency: up to 95.5% DPA UPScale

  25. DPA UPScaleTM ST 10-120 kW FEATURES Todays BENEFITS Reduced weight (10kW =18.3kg, 20kW=21.5kg) Ease of handling ONE Technicians (Ease of Maintenance and Service) High Power Density(272kW / m2) Small foot-print (Expensive floor-space saving) Unity Input PF=0.99(Flat PF curve) Reduced size of Cables and Fuses (Installation Cost Saving) Input THD i = < 3%(Flat THD i curve) Reduced Harmonic Injection to Mains(No need for GENSET over-sizing) Unity Output PF (KW)(Optimize Power @ cosphi 1.0) Blade Server – Friendly Technology(No need for UPS Power Derating @ cosphi 1) High Efficiency(Flat Efficiency Curve) Energy Saving (Reduced Losses and Cooling Energy) DPA UPScale

  26. DPA UPScaleTMBusiness Value of Power Protection With the modular, safe swap UPS systems, you can build your own IT-Facility to meet simultaneously and most accurately: • Higher Availability • Unmatched flexibility to changes • Reduced footprint • Lowest TCO • Product standardization  AND ALL THIS AT BEST POSSIBLE COST DPA UPScale TM DPA UPScale

  27. Thank you for your attention DPA UPScale

More Related