1 / 15

HVACR214 – Electrical for Oil

HVACR214 – Electrical for Oil. Stack Relay. Stack Relay. The stack relay is an older type of primary control that will trip if no flame is detected upon a call for heat. The stack relay senses temperature, not light. >. Stack Relay.

stacie
Télécharger la présentation

HVACR214 – Electrical for Oil

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. HVACR214 – Electrical for Oil Stack Relay

  2. Stack Relay • The stack relay is an older type of primary control that will trip if no flame is detected upon a call for heat. • The stack relay senses temperature, not light. >

  3. Stack Relay • A bi-metal sensor sits inside the furnace flue (exhaust) pipe. When the furnace heats up it heats the element. • (refer to the stack relay handout) >

  4. Stack Relay • As the elements start to move it sequences the contacts. >

  5. Stack Relay • Shows the relay de-energized. The cold contacts are mid-seated and the hot contacts are open. >

  6. Relay De-energized

  7. Stack Relay • Thermostat comes on, energizes 1k and closes 1k1 and energizes the ignition sequence. • Also energizes 2k and 1k2 to close 2k1. This energizes the oil valve and the burner motor. >

  8. Call for heat

  9. Stack Relay • /R closes on the thermostat energizing te 2k and 1k relays, the SS heater , 1K coil and 2K coil. All use 12 volts. • The burner is now energized as well. • As the flame heats up the flue pipe the bi-metal in the stack relay starts to move as well. • This will sequence the hot and cold contacts. >

  10. Warm Up

  11. Stack Relay • As the bar starts to move the heat from the burner starts to move the cold contact and stops the SS heater from heating. • The cold contact has moved away from the SS heater circuit meaning that the flame has been established and lockout is not present. • Safety switch stays closed. >

  12. Stack Relay • Shows interrupted ignition. Once the flame is established the ignition transformer drops out. • When the hot contacts close the cold contacts are completely disengaged de-energizing the 1K relay (ignition transformer). >

  13. Primary Hot

  14. Stack Relay • Shows the control tripped out on a no-flame condition. • The heater got hot as the contacts never sequenced to take it out of the circuit. >

  15. No heat sensed off on safety

More Related