1 / 1

An advanced signal Surge Protection System

JMV specializes in manufacturing recognized Surge Protection Devices and protect your assets from losses. JMV is offering a huge range of surge protection devices which varies not from the external lightning protection to the directly installed protection of the equipments. We have divided our Surge protection devices based on the application and the voltage bearing capacity.

Télécharger la présentation

An advanced signal Surge Protection System

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. F-type Surge Protector JMV/F-#/M: SIGNAL SURGE PROTECTION DEVICES F-type surge protectors inherent the flexible protection of Aerial, Cable and signal transmission happening through Satellite. TV receptors, Antenna, Cable TV and nevertheless all installations, supply unit and receiving equipment are extensively exposed to the atmosphere. For the sake, F-type surge suppressors are used to enhance shielding of the same. The Surge Protection devices prevent surges and over-voltages to a value that will lie above the safe threshold level. They are purposely installed in conjunction to the signal/telecommunication network and are especially designed to safeguard the signals transferred and received without any distortion or loss of information. The provided solution is in honor with IEC-61643-21 that is followed in regard to filter of interference and transients worldwide such that they face a hindrance when travel towards electronic equipments and data/signal lines. the exposed Model JMV/F-2/M JMV/F-3/M JMV/F-4/M Housing Material Metal Degree of Protection IP 20 Number of Ports 2 3 4 Nominal Voltage (Un) 24V DC Max. Continuous Operating Voltage (Uc) 180V DC Nominal Discharge Surge Current (In) 5kA Max. Discharge Surge Current (Imax) 10kA Protection Level (Up) <60V -40 °C to +80 °C Operating Temperature Standards IEC-61643-21 W-50, Sector-11, Noida 201301, India www.jmv.co.in info@jmv.co.in JMV LPS LIMITED

More Related