1 / 14

Case 3 – Increasing hydrogen partial pressure

Case 3 – Increasing hydrogen partial pressure. - Case 3a – Diesel hydrotreater increase H2/oil ratio? purify hydrogen? change liquid feed? decrease pressure drop? Case 3b – Naphtha hydrotreater increase H2/oil ratio? purify hydrogen? change liquid feed?

teneil
Télécharger la présentation

Case 3 – Increasing hydrogen partial pressure

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Case 3 – Increasing hydrogen partial pressure • - Case 3a – Diesel hydrotreater • increase H2/oil ratio? • purify hydrogen? • change liquid feed? • decrease pressure drop? • Case 3b – Naphtha hydrotreater • increase H2/oil ratio? • purify hydrogen? • change liquid feed? • decrease pressure drop?

  2. Case 4 – Pressure Drop • Situation 1 – Poor catalyst loading or poor start-up procedures • Situation 2 – Internals, catalyst strength or corrosion impurities coming into the catalyst bed

  3. Case 4 – Pressure Drop • Possible causes for pressure drop • Reactor - coking, polymerization, particles (FeS), catalyst loading, maldistribution, metal poisons • Exchangers - salts deposition, coking, polymerization, particles deposits

  4. Case 4 – Pressure Drop 3/4" inert balls Reasons for this high pressure drop build-up?? Reasons for the higher pressure drop in the second bed?? ACT 065 - 12 mm ACT 075 - 6 mm HMC 841 - 3 mm 1/4" inert balls 3/4" inert balls HR-448 1.2 mm DENSE LOAD 1/4" inert balls 3/4" inert balls

  5. Case 4 – Pressure Drop

  6. Case 4 – Pressure Drop Catalyst grading bed – trickle bed reactors

  7. Case 4 – Pressure Drop Scale baskets – Gas phase bed reactors Scale baskets are needed in order to provide longer resistance to pressure drop build up. The role of the basket is not intended to retain the fines which should be trapped on the top layer of inert balls, but to act as a fuse in case of pressure build up They should remain clean Vapors + fines Vapors free of fines Fines accumulation Inert balls 3/4" Inert balls 3/4" Catalyst bed

  8. Delta P measured Delta P predicted Case 4 – Pressure Drop Pressure drop must be corrected for process conditions, as gas and liquid flowrates for example

  9. Case 4 – Pressure Drop Feed + H2 After start-up a very high pressure drop Was observed across the reactor Desulphurized product + H2 + H2

  10. Case 5 – Hydrogenation Activity + 2H2 + 2H2S S + 2H2

  11. Case 5 – Hydrogenation Activity Régime cinétique Régime thermodynamique (HDA) (HDA) HDA Equilibre thermodynamique Soufre effluent (ppm) % HDA HDS T1 T2 Température (°C)

  12. Case 5 – Hydrogenation Activity Diminution de la température dans le dernier lit Opération normale température température 0 0 R1 lit 1 quench (0 t/h) lit 2 four R1 R1 quench 0 0 lit 3 R2 R2 R2

  13. Case 6 – Unit Shut-Down In the race of increasing severity in sulphur specifications - NZSD, optimising the unit shut-down and scheduling it as a non routine event is as important for the overall unit performance as a Formula 1 pit stop can be to wining distribution tray removal (mechanical details) reactor inspection under air atmosphere regenerated catalyst pool catalyst activation method catalyst drying catalyst unloading catalyst loading reactor cool down Dedicated flow-bins - FUTURE

  14. Case 6 – Unit Shut-Down   Air coolers Air coolers HP separator LP separator Cooling loop for hydrotreatment units Gasoil cooling loop To LP separator stripper Pre-heat exchangers Normal operating circuit Compressor stripper By pass to be opened at 150°C Pre-heat exchangers dryer From HP separator reactor Furnace maxi cold GO to storage

More Related