1 / 27

ASM Pilot Program Preliminary Design November 1, 2004

ASM Pilot Program Preliminary Design November 1, 2004. What’s the Problem?. Current ASM design not attractive to many existing Demand Response customers: Why? Nodal Pricing for All Usage 4-Second Metering Requirement 5 MW Minimum (must be an individual end-use metered customer)

theo
Télécharger la présentation

ASM Pilot Program Preliminary Design November 1, 2004

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ASM Pilot ProgramPreliminary DesignNovember 1, 2004

  2. What’s the Problem? • Current ASM design not attractive to many existing Demand Response customers: • Why? • Nodal Pricing for All Usage • 4-Second Metering Requirement • 5 MW Minimum (must be an individual end-use metered customer) • Must be available to 11 p.m. (Weekdays)

  3. Size Requirement • Very few Load Response resources with 5 MW or greater of interruption • 6 in CT (121 MW) • 1 in NEMA (15 MW) • Over 100 MW of resources in CT & NEMA under 5 MW • 74 MW in CT • 30 MW in NEMA

  4. Current Demand Response Distribution

  5. Zonal vs. Nodal Settlement • Two types of customers • Customer in constrained area on high price node • Zonal LMP is less than nodal price • Basically must reduce 100% of load to achieve meaningful savings • 2 customers in SWCT with interruptions great than 80% of their load • Customer in constrained area on low priced node • Can obtain benefit through SCNP • Doesn’t need to be involved in reserved for savings • Why would they trouble themselves?

  6. Positive Customer Attributes • The remaining 466 resources are: • What the pilot focuses on • These customers are where we want them • Located in constrained areas • Dispersed within load

  7. Why do a Pilot? • Determine if Demand Response can provide functionally equivalent Reserves: • Dispatched on Nodal Pricing, but settlement on Zonal Pricing • 5-Minute vs. 4-Second Meter Data to ISO-NE’s Control Room • Customers less than 5 MW (or customer aggregations to meet size requirement) • Available to 6 p.m. (Weekdays)

  8. Value of Demand Response • Response Time • Location

  9. Response Time – All Zones (August 20, 2004)

  10. Response Time – Connecticut (August 20, 2004)

  11. Location Demand Response Resources available as of 10/1/2004 ready to respond within 30-minutes

  12. Preliminary Pilot Project Design

  13. Eligibility • Customers • 100 kW Minimum Reduction • Aggregation allowed at Node • With approved M&V plan where necessary (i.e., for aggregations of customers) • Pilot limited to XXX MW and/or YY customers • Limitations resulting from Manual Settlement for Pilot resources • Suppliers (Enrolling Participants) • NEPOOL Participants • Demand Response Providers (Non-participants)

  14. Schedule • Design Phase • Start: 10/1/2004 End: 10/1/2005 • FERC Filing in February 2004 • Implementation Phase • Start: 10/1/2005 End: 5/31/2007 • Pilot will continue until Evaluation Completed. If deemed viable, until incorporated in ASM • Evaluation Phase • Start: 10/1/2006 End: 6/1/2007

  15. Preliminary Design (Continued) • Location • No restrictions. Market Prices will encourage resources in the higher valued locations • OR Limited to Constrained Zones • Availability • 7 a.m. to 6 p.m. Weekdays, Non Holidays • Payment • Forward Reserve Auction Clearing Price • Zonal LMP if Dispatched (No Floor Price)

  16. Preliminary Design (Continued) • Dispatch • Dispatched when Nodal Price > or = Offer Price • Group 1 Resources offered at Strike Price • Group 2 Resources offered at $ ZZ /MWh • Establish Group 2 offered based on expected hours of operation • Day-Ahead Energy Bid • Equal to or greater than the Strike Price described above • Penalty for Non-Performance • Forfeit Forward Reserve Revenue, plus • Pay Replacement Energy at Zonal LMP

  17. Preliminary Design (Continued) • Metering and Communications • Internet Based Communication System (IBCS) • Meter data submitted to Open Solution every 5-minutes • “Dispatch” notice through IBCS • Settlement • Reductions settled at Zonal Price • Customers can remain on existing Retail Rate

  18. Preliminary Design (Continued) • Capacity • Resources eligible for ICAP • Source of Funding • Funding source identical to proposed ASM or current Forward Reserve Market • Real-Time Reserve Payment • If a DR Pilot resource does not clear in the Forward Reserve Auction it can qualify for Real-Time Reserve Payments

  19. Market Issues • Other Demand Response Programs • Pilot DR resource can not provide Forward Reserves and be an OP4 Action resource, at the same time • Pilot DR resources will be enrolled in a 30-minute notice program • Activated on Nodal Price not OP 4 Actions

  20. Market Issues (Continued) • Forward Reserve Purchases • Pilot DR resource selection will be run parallel to Forward Reserve Auction • Pilot DR resources will not effect the Forward Reserve Clearing Price • Presently DR does not meet NPCC requirements • Pilot DR resources will not offset other non-DR Forward Reserve resources

  21. Resource Selection Process • DR resources submit bid in $/kW-Month on same timeline as Forward Reserve Auction • Bid may be zero. • DR bids accepted that are < or = Forward Reserve Clearing Price • DR bids accepted up to _____ MW • Ties broken through pre-determined preference criteria (to be determined) • Location • Allocating among different resource types: emergency generation, direct load control, different customer sectors, etc.

  22. Pilot Budget • ____ MW eligible to participate • Expected average $____/kW per Month Forward Reserve Payment • 20 month duration • Winter 05/06, Summer 06, Winter 06/07 • Total Budget: $__________

  23. Project Team • Demand Response Department • National Labs • Lawrence Berkeley, Oak Ridge, and Pacific Northwest National Laboratories • Demand Response Working Group

More Related