Typical stiffening ring arrangement

Design of stiffening rings Prof. Ch. Baniotopoulos I. Lavassas, G. Nikolaidis, P.Zervas Institute of Steel Structures Aristotle Univ. of Thessaloniki, Greece. Typical stiffening ring arrangement. When used, stiffening rings are placed over the height of the cylinder, separating it to regions

tiffany
Télécharger la présentation

Typical stiffening ring arrangement

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Design of stiffening ringsProf. Ch. BaniotopoulosI. Lavassas, G. Nikolaidis, P.ZervasInstitute of Steel StructuresAristotle Univ. of Thessaloniki, Greece

  2. Typical stiffening ring arrangement When used, stiffening rings are placed over the height of the cylinder, separating it to regions Distances between rings are a question of buckling limit state design (LS3)

  3. Left (stiffened): max σ vm=266 Mpa Right (unstiffened) max σvm=300 Mpa Effects of ring stiffeners on Von mises stress

  4. Left (stiffened): max σz=219 Mpa Right (unstiffened) max σz=240 Mpa The existence of rings should have no effect to the meridional stress. The difference appears around door position. Effects of ring stiffening rings on meridional stress

  5. Effects of stiffening rings on circumferencial shell stresses Left (stiffened): max σθ=63 Mpa Circumferencial stress is distributed over the rings Stiffeners are forcing the cylinder sections to remain circular Right (unstiffened) max σθ=109 Mpa Circumferencial stress is concentrated to the flange positions where the ovalling deformed shape of the cylinder is forced to circular due to the stiffness of the flange

  6. Left (stiffened): max σ vm=115 Mpa Right (unstiffened) max σvm=180 Mpa Stresses on stiffening rings & flanges

  7. Stress distribution over a stiffening ring

  8. Effect of stiffeners to the shell buckling behaviour Buckling mode shapes on a stiffened shell remain within one stiffened region

  9. Use of stiffening rings • Advantage: • - Use of stiffening rings may reduce shell thicknesses mainly to the upper parts of the tower where local buckling is the main design issue • Disadvantage: • Although the cost of the materials is less in a stiffened tower, the cost of the work is more The total cost of the tower may be bigger for the stiffened tower

  10. Code provisions‏

  11. Code provisions‏

  12. Code provisions

  13. Code provisions

  14. Code provisions