MATLAB Feedback Phase II Commissioning D. Fairley
Topics • First Commissioning Results • Feedbacks for Phase II • New Block Diagram • New Requirements • Plan and Schedule D. Fairley
First Commissioning • Longitudinal Feedback working successfully. Currently implemented as 3 different feedbacks • DL1 Energy (or to Spect. Dump) • DL2 and BC2 Energies • DL1, BC2 Energies + BC2 Bunch length • Injector Launch Feedback working successfully • Feedback framework allowed significant configurability during commissioning. • Developed a good working relationship with physicists (J. Frisch, J. Wu) and good understanding of feedback systems for LCLS D. Fairley
Screen Shots D. Fairley
Feedbacks for Phase II • Bunch Charge • Longitudinal will expand to include BC2 energy, BC2 Bunch Length and DL2 Energy • L2 Launch • L3 Launch D. Fairley
LCLS – Accelerator and Bunch Compressor Schematic D. Fairley
New Block Diagram D. Fairley
Feedbacks for Phase II • Decision: Feedbacks implemented in framework will be ‘EPICS only.’ • Additional Feedbacks in MATLAB • Bunch Charge • Longitudinal will expand to include BC2 Energy and BC2 Bunch Length • We have 3 EPICS BPMs for longitudinal; allows 5x5 fully EPICS • Feedbacks in SLC • DL2 Energy • L2 and L3 Launch D. Fairley
New Requirements • Create a more production oriented feedback system • Separate ‘Configuration’ from runtime feedbacks. • Make feedback controllable from any kiosk • Display more status and enhance alarms • Automatically switch configurations • Make feedbacks detect beam line conditions and switch configuration accordingly • For example, TD11 stopper status, magnet power supply settings, etc • Add weighting factors to transverse feedback algorithm • Add a mask matrix to longitudinal feedback algorithm • Runtime adjustment of gains, weighting factors, mask matrix • Place these in soft IOC so they can be changed while feedback is running. D. Fairley
Plan and Schedule • Make Feedback more ‘production’ oriented • Separate Configuration, make controllable from any kiosk - done • Status in EDM, alarms – October, in progress • Bunch charge feedback • October, In progress – must be ready to commission in December • Algorithm enhancements (gains, weighting, mask matrix) • Longitudinal – November • Transverse – November-December • Automatic configuration switching • December • Experimental testing with mask matrix, weighting • Jan – May, when we can get machine time • Experimental testing with changing beam line conditions • Jan – May, when we can get machine time D. Fairley