An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Validation of “effective nonionizing energy loss (NIEL)” for high-energy(>1MeV) electrons in SiliconESA contract n°4000111337/14/NL/SW T. Nuns, C. Inguimbert, S. Soonckindt - ONERA- DPhIEE R. Burgon, B. Dryer, D. Hall, P. Smith - The Open University Centre of Electronic Imaging C. Poivey - ESA ESTEC

  2. Outline • Goal of the study • Presentation of the tested devices • Irradiation plan • Preliminary results • Photodiodes • CIS • CCD • NIEL calculations and modeling • Future work and analysis

  3. Goal of the study • Context • Prepare the Jupiter Icy moons Explorer (JUICE) mission • Mission radiation environment is dominated by electrons • Higher electrons energies than Earth environment • High total ionizing dose levels (some 100 krad after 10 mm equivalent Al shielding) • Electron are expected to be the main contribution for TNID • The NIEL is used to scale the electrical degradation, but • No experimental data available for a validation of the NIEL scaling for high electron energies • Some NIEL discrepancies are observed for low energies electrons • Explained by the “Effective NIEL” model proposed by C. Inguimbert et al. (ONERA); discrepancies are probably due to NIEL calculation uncertainties • Need of experimental data over 1 MeV for validation • Goals • Validation of effective NIEL model for high energy electrons • Validation of other degradation models such as DCNU for imagers for high energy electrons • Improvement of the understanding of TNID physical degradation mechanisms for high energy electrons and protons

  4. Effective approach • Experimental study • Select 3 device types • CMOS Image Sensor (CIS) managed by ONERA • Charge Coupled Device (CCD) managed by the Open University CEI • Photodiode managed by ONERA • Irradiation • High energy electron irradiation • Proton irradiation for NIEL scaling verification • Gamma irradiation for evaluation of the total ionizing dose effect • Calculation and Modeling • Evaluate the effective NIEL for high electron energies and gamma irradiation (60Co) and compare the experimental data with the NIEL scaling • Modeling the Dark Current Non Uniformity (DCNU) on the imagers and compare with the experimental data • Status of the study • Irradiations and measurements done (TRB passed) • Data analysis and final report due for the end of May 2017

  5. CIS e2v Saphirre • CIS Saphirre EV76C560 E2V (ONERA) • 1.3 Mpixel 1024 * 1280 pixel array • Pixel pitch 5.3 µm Pinned photodiode • Global and rolling shutter modes (only rolling measured) • 10 bits digitized output • Procurement of 20 samples with the same date code • 9 for the test plan • Measurements • Conversion factor (e-/lsb) at 21°C • Dark current at 15, 21, 27, 35°C • Mean dark current • DCNU • Activation energy • Random Telegraph Signal (RTS) at 15 and 21°C on ROI 100 x 100 pixels, 10 000 samples

  6. Photodiode PIPS Canberra • Photodiodes PIPS (PassivatedImplantedPlanarSilicon) FD50-14-300RM Canberra (ONERA) • Particle detector • 1 cm² area • 300 µm depth full depleted P/N junction • Procurement of 22 sampleswith the same wafer • 18 for the test plan • No window on the devices • Measurements • I(V) and C(V) forward and reverse at 15, 21, 27, 35°C • Extraction of the activation energy

  7. CCD e2v presentation • CCD e2v 47-20 (The Open University) • 1 Mpixel frame transfer • 13 x 13 μm pixels • Back illuminated • Advanced Inverted Mode Operation (AIMO) • 2 e- r.m.s. read noise • Affordable COTS • Good space heritage • 10 devices used in the study • 9 irradiated and 1 control

  8. CCD tests performed • System calibration at -20 °C with 5.9 keV X-rays incident on the CCD and the system noise calculated from the standard deviation of the signal in the serial overscan, using the gain calibrations. • Charge Transfer Inefficiency (CTI) using Extended Pixel Edge Response (EPER) at -20 °C at four signal levels (1ke-, 5ke-, 10ke, 20ke-) using light from a LED. • Pinning voltage at -20 °C - the dark current is measured for Vss between 0V and 11.6V with the onset of pinning used as a measure of the eventual flatband voltage shift from ionising radiation. • Dark current (DC) and Dark Signal Non-Uniformity (DSNU) and at -30, -20, -10, 0, 10 and 15 °C. • Activation energy of the dark current - using the data from (4) the dark current is plotted against the 6 temperature points in 1/T. The slope of the line gives the activation energy of the dark current. • RTS at 15 °C – records 1000 dark current images from a ROI of 100x100 pixels from the image and store regions separately.  NIEL CCD test Camera System

  9. Irradiation plan • Apply the same total ionizing dose on the samples • The applied total dose is the same whatever the energy • Up to 30 Gy(Si) for proton irradiations • Up to 100 Gy(Si) for electron and gamma irradiations • Intermediate doses for photodiodes • Irradiation devices unbiased in the dark, room temperature • Measurements 1 month after irradiation

  10. Photodiode: Preliminary dark current increase • Example at 27°C reverse bias • Consistent behaviour between the maximum fluence and the half fluence

  11. Photodiode: Preliminary dark current damage factor • Shapes are consistent all together; no issue of range at 1 MeV electrons or 17.25 MeV protons • Exception for Gamma (ionizing dose effect ?)

  12. CIS: Preliminary conversion factor • Small decrease of the conversion factor • Not taken into account in the dark current variation (negligible)

  13. CIS: Degradation homogeneity 1/2 • Dark current increase is homogeneous accross the rows and columns • Homogeneous irradiation Harwell 6,5 MeV proton irradiation PSI 200 MeV proton irradiation

  14. CIS: Degradation homogeneity 2/2 • Border effects for electron and gamma irradiation. Probably ionizing dose effect Jyväskylä 20 MeV electron irradiation ONERA 1 MeV electron irradiation

  15. CIS:Preliminary mean dark current increase damage factor • Large impact of the total ionizing dose effect for electrons. Example 27°C • Have to separate the peak of the DCNU and the tail to extract the DD effect

  16. CCD 47-20: Preliminary dark signal data

  17. CCD 47-20: Preliminary RTS data RTS pixels noisy pixels 6 MeV e- 70 MeV P+ 100 Gy γ

  18. NIEL scaling dark current photodiodes • NIEL and effective NIEL calculated • Protons, electrons, gamma • Comparison with damage factors • Dark current of the photodiodes • Minority carriers’ lifetime (ONERA internal study) • The same CANBERRA photodiodes • Hamamatsu S1337-33BQ photodiodes • Results seem consistent with the electron effective NIEL curve • CCD and CIS data not ready yet

  19. Future work of the study • Measurement analysis • Extract the relevant data • Compare with the NIEL calculations • DCNU Modeling • Compare with the experimental data • Include the possible total ionizing dose effect • Final report planned for end of May 2017