1 / 21

Pyronix House, Braithwell Way, Hellaby, Rotherham, South Yorkshire, S66 8QY, England

www.pyronix.com. Pyronix House, Braithwell Way, Hellaby, Rotherham, South Yorkshire, S66 8QY, England Tel +44 1709 700 100, Fax +44 1709 533 429. Matrix 832 Main Board. 17V DC Power supply 7,2 A/H 12V AC Battery Dedicated Bell (+/-) supply Dedicated Bell Tamper Global System Tamper

tymon
Télécharger la présentation

Pyronix House, Braithwell Way, Hellaby, Rotherham, South Yorkshire, S66 8QY, England

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. www.pyronix.com Pyronix House, Braithwell Way, Hellaby, Rotherham, South Yorkshire, S66 8QY, England Tel +44 1709 700 100, Fax +44 1709 533 429

  2. Matrix 832 Main Board • 17V DC Power supply • 7,2 A/H 12V AC Battery • Dedicated Bell (+/-) supply • Dedicated Bell Tamper • Global System Tamper • PGM 1 N/O-N/C(Relay) • PGM 2 • PGM 3 • PGM 4 • KD - System bus output • Zones 1-4 • +AUX- • Zones 5-8 • GND connection • Telephone line - heavy duty lighting protection • RS 232 output • Local zone expander slot for 8/16 zones expander • NVM reset pin

  3. Matrix Expanders • Zone expanders: - Local plug in 8/16 zone expander - plug on the main board - Remote 8/16 zone expander - on the bus • PGM expanders: - 8 PGM transistor expander - on the bus - 8 PGM relay expander - on the bus

  4. Matrix Keypads - MX-LED Keypad: - 2 seven segment display - Icon based - 9 status LED - PA, Fire and Medical buttons - Public & Private mode - Addressable per partition number - MX-LCD Keypad: - 16 characters LCD display - Multilingual - PA, Fire and Medical buttons - Public & Private mode - Addressable per partition number

  5. Matrix Proximity Reader • Proximity reader: - Bus proximity reader - 5 Status LED indication - Proximity card - Proximity tag - Public & Private mode - Addressable per partition number - Activate / Disactivate PGM’s

  6. Matrix PC Software • Matrix UDL software: - Local RS232 and modem connection - Used for Programming the system - Multilingual support - Proximity tag • Matrix PC Maintenance / Monitoring software: - Modem connection - Used for programming and monitoring the system - Multilingual support

  7. AC fail warning - enable / disable • AC frequency - 50 / 60 Hz • Battery monitoring - enable / disable • Global tamper activation polarity - 0V or 12V • NVM reset - from engineer mode and link / link only • Real time clock - AC / Quartz based • EVENT MEMORY - 300 events with time & date • Alarm in telephone line fail - enable / disable • Limit log and event reporting - enable / disable • Tamper on bus device missing - enable / disable • Put Restorals In Log • Arm Mode Settings • Engineer Lockout Global System Options

  8. Zone Configurations - max 32 zones • Zone attributes: - Chime - Test - Mask Any zone can have different attribute. Zone types: - Entry / Exit - Access - Immediate - Omitted (Bypassed) - Fire - Personal Attack - 24 H - Tamper - Latch Keyswitch - - Momentary Keyswitch - Medical - Unused Each zone type can be allocated to one zone at a time. • Zone configurations: - N/C - DEOL - Zone Doubling - Fast Zone response These options are global. • Zone partition allocation: - Partition 1 - Partition 2 - Partition 3 - Partition 4 Each zone can be allocated to only one partition.

  9. Example Installation Partition 1 Partition 2 Partition 3 Partition 4

  10. User Codes - max 32 codes • User codes attributes: - Omit (Bypass) zones - Duress code - Duress disable - Arm code - Disarm code - Temporary code • User code types: - Master user code - Limited user code • User codes partition allocation: - Partition 1 - Partition 2 - Partition 3 - Partition 4 - Any combination from the above

  11. Example User Codes Configuration Code 1 - Master User Code 2-5 - Limited User Code 14 - Duress Code 15 - Cleaner Code 16 - Patrol Code 1-16 allocated to the P1 Partition 1 Partition 2 Code 6 - Master User Code 7-9 - Limited User Code 14 - Duress Code 10- Master User Code 11-13 - Limited User Code 14 - Duress Partition 3 Partition 4

  12. Partition 1 • Partition 2 • Partition 3 Arm Modes • Partition 4 • Arm mode A: - Timed exit - Final exit - Silent arm - Home / Away - Key zone arm • Arm mode B: - Timed exit - Final exit - Silent arm - Home / Away - Key zone arm • Arm mode C: - Timed exit - Final exit - Silent arm - Home / Away - Key zone arm • Arm mode D: - Timed exit - Final exit - Silent arm - Home / Away - Key zone arm

  13. Global timers - all partitions: - AC fail delay report, RTC correction factor • Partition timers : - Partition 1 - Partition 2 - Partition 3 Timers - Partition 4 Partition 1: - Bell time - Entry time - Exit time - Bell delay - Final exit delay - Inactivity auto-arm - Auto-arm at hour Partition 2: - Bell time - Entry time - Exit time - Bell delay - Final exit delay - Inactivity auto-arm - Auto-arm at hour Partition 3: - Bell time - Entry time - Exit time - Bell delay - Final exit delay - Inactivity auto-arm - Auto-arm at hour Partition 4: - Bell time - Entry time - Exit time - Bell delay - Final exit delay - Inactivity auto-arm - Auto-arm at hour

  14. System Partition Options - Matrix is optioned with 4 partitions - virtually independent systems with common hardware. To each of them can be allocated one or more of the following devises/attributes: • Keypad - 1 up to 4 • Proximity reader - 1 up to 4 • Zones - 1 up to 32. Any zone type available from the menu • PGM - 1 up to 12. Any PGM type available from the menu • Arm modes - 4 arm modes available per partition • Account code - One a/c per partition • User codes - 1 up to 32. Any user code attribute available from the menu • Partition dependency - any combination • Partition options - independently programmable per partition

  15. Partition Dependency - Common Partition • Area 1 - Armed in Away mode • Partition 3 - Armed in Away mode • Partition 2 - Armed in Away mode • Area 4 - This will arm when all areas armed in Away mode

  16. PGM polarity: - N/C - N/O • Programmable Outputs: - E- - C+ - Controlled from keypad - Follow zone - Follow telephone line fail - Follow kiss off - Shock / fire sensor reset - Strobe - Follow PA alarm - Follow confirmed alarm - Follow tamper alarm - Bell - GRN fire detector - Twin Alert - Follow Fault - General Fault • RS 232 output Outputs • PGM partition allocation : - up to 12 PGM can be allocated to any of the available 4 partitions

  17. Matrix Digital Communicator • Communication to Servicing company • Communication Formats: - Contact ID - Fast Format - PC format - Pager format - Voice • Communication to user • Communication to Monitoring company

  18. Communication Formats: - Contact ID - Fast Format Communication to Monitoring company • Events Send Options: Disarmed A, B, C, D Restorals Alarm Alarm Alarm PA alarm PA alarm PA alarm Fire alarm Fire alarm Fire alarm Maintenance Maintenance Maintenance Open /Close Open /Close Open /Close • Events Group reporting To telephone n. 1 To telephone n. 1+2 To both numbers If programmed any event will be send to n. 3 • Communication Options: - 4 account codes - Test dial - min or days - 9 telephone numbers - 3 numbers for group reporting - Telephone line monitoring - Send open after alarm - AMC dial in mode - Communication priority events

  19. Communication Formats: - PC Pyronix format Communication to Servicing Company • Matrix UDL software: - Local RS232 and modem connection - Used for Programming the system - Multilingual support • Matrix PC Maintenance / Monitoring software: - Local RS232 and modem connection - Used for programming and monitoring the system - Multilingual support • Communication Options: - 4 account codes - Test dial - min or days - 9 telephone numbers - 3 numbers for group reporting - Telephone line monitoring - Send open after alarm - AMC dial in mode - Communication priority events

  20. Communication to the User • Communication Formats: - Pager forma - Voice