1 / 20

D. Attié, P. Colas, M. Dixit, Yun-Ha Shin (Carleton and Saclay)

Analysis of Micromegas Large Prototype data. D. Attié, P. Colas, M. Dixit, Yun-Ha Shin (Carleton and Saclay). 3rd analysis meeting - June 22, 2009. Outline. Comparison between two resistive modules Resolution measurements Distortions Momentum resolution.

varick
Télécharger la présentation

D. Attié, P. Colas, M. Dixit, Yun-Ha Shin (Carleton and Saclay)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Analysis of Micromegas Large Prototype data D. Attié, P. Colas, M. Dixit, Yun-Ha Shin (Carleton and Saclay) 3rd analysis meeting - June 22, 2009 P. Colas - Analysis meeting

  2. Outline • Comparison between two resistive modules • Resolution measurements • Distortions • Momentum resolution P. Colas - Analysis meeting

  3. Bulk Micromegas panels tested at DESY November 2008 May-June 2009 Standard bulk Micromegas module Carbon loaded kapton Micromegas module • Three panels were successively mounted and tested in the Large Prototype and 1T magnet: • standard anode • resistive anode (carbon loaded kapton) with a resistivity ~ 2.8 MΩ/□ • resistive ink (~1-2 MΩ/□) ready for next beam tests P. Colas - Analysis meeting

  4. Beam test conditions at B=1T • frequency tunable from 1 to 100 MHz (most data at 25 MHz) • 12 bit ADC (rms pedestals 4 to 6 channels) • Bulk Micromegas detector: 1726 (24x72) pads of ~3x7 mm² • AFTER-based electronics (72 channels/chip): • low-noise (700 e-) pre-amplifier-shaper • 100 ns to 2 μs tunable peaking time • full wave sampling by SCA • Beam data (5 GeV electrons) were taken at several z values by sliding the TPC in the magnet. Beam size was 4 mm rms. P. Colas - Analysis meeting

  5. Determination of z range • cosmic run at 25 MHz of sampling frequency  time bin = 40 ns • TPC length = 56.85 cm in agreement with survey 190 time bins P. Colas - Analysis meeting

  6. Beam data In addition to January data, new beam data at 1T were taken : 500 ns shaping, with and wo zero suppression, z=5,10,15,20,25,30,40,50 Frequency scan Electronic gain scan (change amplifier gain, compense with gas gain) Laser test, phi scan Excel file exists, most data converted to LCIO P. Colas - Analysis meeting

  7. Pad signals: beam data sample • RUN 284 • B = 1T • T2K gas • Peaking time: 100 ns • Frequency: 25 MHz P. Colas - Analysis meeting

  8. Two-track separation φ r z P. Colas - Analysis meeting

  9. Determination of the Pad Response Function  Pad pitch • Fraction of the row charge • on a pad vs xpad – xtrack • (normalized to central pad charge) • Clearly shows charge spreading • over 2-3 pads • (data with 500 ns shaping) • Then fit x(cluster) using this • shape with a χ² fit, • and fit simultaneously all lines xpad – xtrack (mm) xpad – xtrack (mm) P. Colas - Analysis meeting

  10. Residuals (z=25 cm) row 1 row 2 row 3 row 4 row 5 row 6 Residuals (xrow-xtrack) are gaussians P. Colas - Analysis meeting

  11. Residual bias (z=25 cm) row 0 • Bias remaining after correction: • mean of residual xrow-xtrack = f(xtrack) • Variation of up to 50 μm • with a periodicity of about 3mm (pad width) row 1 row 2 row 4 row 8 row 3 row 5 P. Colas - Analysis meeting

  12. Spatial resolution • Resolution at z=0: σ0 = 54.8±1.6 μm with 2.7-3.2 mm pads (wpad/55) • Effective number of electrons: Neff = 31.8±1.4 consistent with expectations Preliminary P. Colas - Analysis meeting

  13. Field distortion measurement using laser • two laser devices installed on the endplate to light up photosensitive pattern • on the cathode (spots and line) • deterioration of resolution at z > 40 cm : due to low field 0.9 to 0.7 T • in the last 20 cm (significant increase of transverse diffusion) Photoelectrons from the cathode pattern B field map of the magnet 50 cm 30 cm 5 cm Beam position P. Colas - Analysis meeting

  14. Description of the resistive anodes Resistive Kapton ResistiveInk Resistive Ink Resistive Kapton Glue 1-2 μm Glue 1-2 μm Prepreg Prepreg PCB PCB P. Colas - Analysis meeting 14

  15. Comparison at B=1T, z ~ 5 cm Resistive Kapton ResistiveInk • RUN 310 • vdrift = 230 cm/μs • Vmesh = 380 V • Peaking time: 500 ns • Frequency Sampling: 25 MHz • RUN 549 • Vdrift = 230 cm/μs • Vmesh = 360 V • Peaking time: 500 ns • Frequency Sampling: 25 MHz P. Colas - Analysis meeting 15

  16. Pad Response Functions, z ~ 5 cm ResistiveInk xpad – xtrack (mm) xpad – xtrack (mm) Γ = 7 mm Γ = 11 mm δ = 10 mm δ = 13 mm xpad – xtrack (mm) xpad – xtrack (mm)  σ0 = 68 μm  σ0 = 130 μm ! ResistiveKapton P. Colas - Analysis meeting 16

  17. 2.2 GeV Momentum P. Colas - Analysis meeting 17

  18. Further tests for Micromegas Resitive technology choice In 2008/2009 with one detector module In 2010 with 7 detector modules. Reduce the electronic with possibility to bypass shaping Front End-Mezzanine 4 chips Wire bonded P. Colas - Analysis meeting 18

  19. Conclusions • Two Micromegas with resistive anode have been tested within the EUDET facility using 1T magnet to reduce the transverse diffusion • C-loaded Katpon technology gives better result than resistive ink technology • First analysis results confirm excellent resolution at small distance with the resistive C-loaded Kapton: 55 μm for 3 mm pads • The moving table is necessary to fix the inhomogeneous B field at high z • Plans are to test several resistive layer manufacturing process and RC, then go to 7 modules with integrated electronics. • Next step is making 2 new detectors, identical except the routing (we have 2 routings) both in CLP but a new, lower resistivity one. Should be close to ideal. P. Colas - Analysis meeting 19

  20. Acknowledgments • Saclay, France: • D. A. • P. Colas • M. Riallot • Carleton Univ., Canada: • M. Dixit • Y.-H. Shin • S. Turnbull • R. Woods • DESY/EUDET P. Colas - Analysis meeting