An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. AcuSolve™ A Practical Fluid/Structure Interaction November 2004 ACUSIM Software Inc., 2685 Marine Way, Suite 1215, Mountain View, California 94043 Tel: (650) 988-9700 Fax: (650) 988-9770 info@acusim.com http://www.acusim.com Acusim Software Inc. Proprietary Information

  2. Fluid/Structure Interaction (FSI) • FSI is defined as simulating the bi-directional interaction (coupling) between fluid flow and a deforming solid/structural model. • This definition is very specific. • Does not include: • Fluid and thermal solid/structure analysis (ie., Conjugate heat transfer) • Fluid coupling with rigid body dynamics • Which are both supported by AcuSolve • Examples: • Flow induced vibration of a solid wall and coupling to Computational Aero Acoustics (CAA) • Vortex Induced Vibration (VIV) modeling of oil platform risers • Deformation of vein walls due to pulsing blood flow

  3. Linear Solid/Structure Deformation • Assume 1: linear solid/structural deformation • Linear finite element dynamic system of equations: • Where • : Nodal acceleration • : Nodal velocity • : Nodal displacement • : Mass matrix - Not a function of solution • : Damping matrix - Not a function of solution • : Stiffness matrix - Not a function of solution • : Forcing vector - Includes fluid forces on the structure

  4. Eigensystem • Consider the Eigenvalue problem • Where • : ith Eigenvalue • : ith Eigenvector • : Number of modes (=1 to 100 or more) • Assumption 2: Eigenmodes are sufficient to well represent the dynamic behavior of the solid/structural model

  5. Reduced System • Projection of dynamic system into the Eigenspace: • Where • This is independent ODEs.

  6. Solution of ODE • Solution of the independent ODEs: • is first computed from the flow field • is then projected to • is solved using a Kinetic-energy conserving time integrator • Given the solution of the ODEs, we have

  7. Practical FSI • Step 1: Solid Model • A solid/structural finite element mesh is created • The first Eigenmodes are computed • May use any existing linear solid/structural code: • Abaqus, Ansys, Nastran, …, analytical • Step 2: Projection • An independent fluid mesh is created • Fluid and solid surfaces in contact are identified • Eigenvectors are projected from the solid to fluid surface nodes Solid Elements Fluid Elements Fluid Surface Nodes

  8. Practical FSI (cont) • Step 3: AcuSolve • Input the ODE coefficients and projected Eigenvectors • Solve the transient coupled flow and linear deformation • Given the solution of ODEs and Eigenvectors • Construct and impose BCs on mesh displacement or flow velocity of surface nodes • Given the flow solution • Compute the nodal forces • Multiply by Eigenvectors to get the ODE forces • Time advance the ODE solution • Step 4 (optional): Post processing • The AcuSolve’s ODE solution may be used for fatigue and other structural analyses.

  9. Advantages • The fluid and solid codes are run independently and separately • No run time coupling is required • Each may be run with a different time increment and duration • No fluid mesh size limitation imposed by FSI • Significantly more stable than alternative approaches • Eliminates the hassle of coupled solution • Eliminates high wave number modes, yields smooth coupling • Very efficient • Problem setup • CPU time

  10. Limitations • Only linear solid/structural analysis accomodated • More precisely, only constant and independent coefficients are currently accommodated • Only a small number of modes is practical • There is no inherent limitation on this, only practical ones • Fluid forces are treaded explicitly in the ODE time integrator • That is, they are one half step behind

  11. First Solution • This technology is brand new to AcuSolve • First solution

  12. Input File • The ODE coefficients are entered as FLEXIBLE_BODY( "baffle" ) { equation = mesh_displacement num_modes = 1 mass = { 200 } stiffness = { 50 } damping = { 0 } external_force = { 0 } initial_displacement = { 0 } initial_velocity = { 0 } initial_force = { 0 } surface_outputs = { "baffle" } } • Where the SURFACE_OUTPUT"baffle" gives the forces on the contact fluid surface

  13. Input File (cont) • Boundary condition NODAL_BOUNDARY_CONDITION( "baffle mesh_x_displacement" ) { nodes = Read( "channel.baffle.nbc" ) variable = mesh_x_displacement type = flexible_body flexible_body = "baffle" nodal_modes = Read( "channel.baffle.xmd" ) } NODAL_BOUNDARY_CONDITION( "baffle x_velocity" ) { nodes = Read( "channel.baffle.nbc" ) variable = x_velocity type = match_mesh_velocity }

  14. Projection From ANSYS • Solve an ANSYS Eigenvalue problem • Extract the Eigenvalues using acuAnsys2Pev.mac macro • This creates the files • nodes.dat coordinates file • elems.dat elements file • mode??.dat eigenvalue & -vectors of mode ?? • Identify the fluid nodes in contact with the solid • Create a coordinate file for those nodes, say called fluid_fsi.crd

  15. Projection From ANSYS (cont) • Project the Eigenvectors acuPev –problem fsi \ -from raw \ -fcrd fluid_fsi.crd \ -crd nodes.dat \ -cnn elems.dat \ -mode mode01.dat,mode02.dat,... • Optionally, you may add “-cnndim 2” for 2D ANSYS mesh (such as plates and shells)

  16. Projection From ANSYS (cont) • acuPev program • Creates the files • fluid_fsi.crd.xmd Eigenvectors in x-direction • fluid_fsi.crd.ymd Eigenvectors in y-direction • fluid_fsi.crd.zmd Eigenvectors in z-direction • These can be passed directly to nodal_modes parameter in NODAL_BOUNDARY_CONDITION command. • Also creates outputs lines like acuPev: Eigenvalue 1 vec l2/linf = 2.50000e+00 ... acuPev: Eigenvalue 2 vec l2/linf = 4.00000e+00 ... • These are the Eigenvalues that may be passed directly to the stiffness parameter of FLEXIBLE_BODY command.