1.11k likes | 2.47k Vues
Stability testing of Active pharmaceutical ingredients. Hua YIN. References. This presentation make reference to: API Stability Lynda Paleshnuik. Assessment workshop. Copenhagen January 2010. References. Generics Guideline
E N D
Stability testing of Active pharmaceutical ingredients Hua YIN
References This presentation make reference to: API Stability Lynda Paleshnuik. Assessment workshop. Copenhagen January 2010.
References Generics Guideline Stability Testing of APIs and FPPs -- WHO Stability Guide in TRS953 (2009) Annex 2: ICH Q1(A, B, C, D and E) Variation Guidance Appendix 4 (Stability Requirements for Variations) (TRS 943) Guideline on stability testing for applications for variations to a marketing authorization (EMA 2011) FDC guideline-- TRS 929 Annex 5 (appendix 3, Table A.1) Good storage practices: TRS 908 FDA, EMA—stability for existing API and FPP For PQP, when there are contradictions, the Generic quality guideline prevails
Stability –purpose • "Provide evidence of how the quality of an API or FPP varies with time under the influence of a variety of environmental factors such as temperature, humidity and light" • "Study of product-related factors that influence its quality, for example, interaction of API with excipients, packaging materials. In fixed-dose combination FPPs (FDCs) the interaction between two or more APIs also has to be considered.
API Stability –purpose • Understanding of the molecule • Validation of analytical methods • Selecting packaging • To establish a re-test period for the API. In exceptional cases, e.g. for unstable APIs, a shelf-life is given. • To establish storage conditions. • To establish/justify specification limits--derived from a consideration of available stability data
Overview • Stress Testing • Stability indicating method • Accelerate and long term • Evaluation • Stability Commitments • Examples • Common Deficiencies
API Stress Studies Stability testing under conditions exceeding those used for accelerated testing. Used to: • establish the inherent stability characteristics of the molecule • establish the degradation pathways • identify the likely degradation products • validate the stability indication power of the analytical methods
API Stress Studies The information can be used in: • Formulation development • Manufacturing process development • Ensure proper selection of stability-indicating analytical techniques • Preparing reference material of identified degradation products • Degradation pathways elucidation • Selection of proper packaging
API Stress Studies When available, it is acceptable to provide relevant data published in the scientific literature to support the identified degradation pathways and products. If “protect from light” is stated in one of the officially recognized pharmacopoeia for the API, it is sufficient to state “protect from light” on labeling, in lieu of photostability studies, when the container closure system is shown to be light protective. When no data are available, stress testing should be performed.
API Stress Studies How to design stress studies? • No detailed stress testing strategy in Guidelines, i.e. experimental conditions and duration may need to be varied depending on the nature of the drug substance • Generic guideline refers to FDC guideline appendix 3, table A.1 (TRS 929 Annex 5) -- as examples
API Stress Studies • 1 API batch (pilot scale, representative of the production batch) • Should include: • Effect of temperatures • Humidity • Acid and base hydrolysis • Photolysis (generally as per Q1B) • Oxidation
API Stress Studies • How much stressing is enough ? • 10-30% loss of API assay (FDC guideline, as well as Generic guideline) • between 5% to 20% degradation (some literature) • approximately 10 % degradation is optimal for method validation (as assay limits are normally 90-110%) • balance between "purposeful degradation" and irrelevant artifacts (e.g., secondary degradation products). • degradation products not formed during accelerated or long-term stability studies--need not always to be examined
Stress studies: Approach for Assessment: DO • Check if data is provided, either generated by supplier/applicant or from literature references • Check for compendial statement, “protect from light”. • Check that conditions are adequate • Check the extent of degradation • ≈10% = adequate degradation • little or no degradants : verify if conditions are "harsh" enough. If yes, the API is considered stable. • Conclude on the degradation pathways, stability nature of the API
Stress studies: Approach for Assessment : DON’T - spend excessive time with degradants generated in stress studies if they are not formed in practice. The impurities/degradants that must be closely investigated are those appearing when stored at long-term and accelerated conditions at greater than (or approaching) the identification threshold (the limit of individual unknowns, 0.1%).
Stability indicating method Without analytical methods it is not possible to know what has happened during stability Assay Impurities/Degradation Products Chiral Purity Dissolution Preservative Content
Stability indicating method • This is a chicken and egg problem • need analytical methods to analyze stability data • need stability information to validate methods • Start with preliminary method based on what is known of drug substance • can determine content of drug substance, can separate the known or expected degradants • Use preliminary method to analyze stress stability studies • evaluate ability of method to separate degradants i.e the specificity --confirm peak purity, mass balance • Use this information to modify/improve method • stability studies and analytical method development work together
API Stability:Stability protocol • Number of batch(es) and batch size(s) • Container closure system (s) • Conditions of storage • Tests and acceptance criteria (reference to test methods) • Testing frequency
API Stability:Selection of Batches Primary Batches: API batches used in stability studies to establish retest period. Prequalification: 3 batches of at least pilot scale (as per Q1A). *Pilot batches must be of the same synthesis route, and with method of manufacture and procedure which simulates the final process for production batches.
API Stability:Container Closure System • Should be the same or simulate the container proposed for storage/distribution unless justification provided (ie container used in studies is less than or equally protective compared to proposed container) • A functionally similar container may be used to mimic the cardboard or plastic drum that is usually used to store raw material
API Stability:Tests and acceptance criteria Specifications: test attributes susceptible to change: • Appearance (description) • Degradation (related substances) • Assay • Enantiomer • Plus others susceptible to change, e.g. LOD Methods: • If same as in API specs, cross-reference • If different, provide methodology and validation data for impurity and assay methods • Methods should be stability-indicating
API Stability:Tests and acceptance criteria Other parameters to be monitored • The API is low solubility and micronized, and the FPP is low dose (common for RH products). PSD is critical. PSD stability should be monitored for potential increase in particle size (due to discreet particles or particle agglomerates). • For a low solubility API, if there is evidence that polymorph stability may be an issue, polymorphic form should be monitored during stability studies.
API Stability: Storage Conditions Climatic Zones • Zone I: 21°C/45% RH • Zone II: 25°C/60% RH (subtropical) • Zone III: 30°C/35% RH(hot/ dry) • Zone IVA: 30°C/65% RH (hot/ humid) • Zone IVB: 30°C/75% RH (hot/ very humid) Long term stability studies should cover all climatic zones if possible
API Stability: Storage Conditions • The required long-term storage conditions for APIs in the Prequalification Programme: • 30ºC±2ºC/65%±5%RH or 30ºC±2ºC/75%±5%RH. • Alternative conditions should be justified, e.g. storage at 30ºC is inappropriate for the API. (e.g. Tenofovir disoproxil fumarate ) • If no stability studies at 30ºC, commitment to commence studies at 30ºC on the next 3 production scale batches, and to revise the storage condition/retest period, if applicable
API Stability: Testing Frequency Long term: Year 1: every 3 months; Year 2: every 6 months Subsequent years: annually Accelerated: Minimum three points including t0 and tfinal, e.g 0, 3, 6. Intermediate: Four points including t0 and tfinal, e.g 0, 6, 9, 12.
Minimum data requirements at time of submission *Where long-term conditions are 30ºC±2ºC/65%±5%RH or 30ºC±2ºC/75%±5%RH, there is no intermediate condition.
What are expected in the stability reports? • General information: name, manufacturing sites, date of manufacturing of the API; batch number, batch size, container/clourse • Stability data in tables or graphs or both • Evaluation • Justify parameters tested (OoS, OoT discussion) • Statistical analysis, if necessary • Conclusions • Proposed retest date for drug substance • Proposed shelf-Life, if applicable • Proposed storage condition
API Stability: Evaluation • Collect information • The innovator (e.g. EPAR) • Literature • Prequalified products • APIMFs • Confirm the number of batches, batch size, packaging, storage conditions, test frequencies, specification. • Review the stability results. • For an API, “significant change” is failure to meet the specification for any parameter
API Stability: Evaluation • Begin with any significant change at the accelerated condition, and • the intermediate condition, if appropriate • then, review the trends and variability of the long-term data • Establish re-test and storage condition • Refer ICH Q1E appendix A decision Tree for any extrapolation
API Stability: Evaluation Extrapolation of data: Extend the retest period or shelf life beyond the period covered by long-term data A retest period or shelf life granted on the basis of extrapolation should always be verified by additional long-term stability data as soon as these data become available.
API Stability: Evaluation • No significant change at accelerated condition (6 months ) • Little/no change and little/no variabilityfor accelerated and long term data • statistical analysis is unnecessary X= Period covered by long-term data Y= proposed retest period or shelf life
API Stability: Evaluation • No significant change at accelerated condition (6 months ) • Change and/or variability observed for accelerated and/or long term data • Extrapolation may be proposed by providing Statistical analysis and/or relevant supporting data * *Satisfactory long term data from development batches (with a closely related formulation, packaged in similar container closure system, smaller scale than the primary batches)
API Stability: Evaluation • Significant change at accelerated condition, but • No Significant change at intermediate condition • Extrapolation may be proposed by providing Statistical analysis and/or relevant supporting data
API Stability: Evaluation Significant change at accelerated condition, And Significant change at intermediate condition No extrapolation is allowed In addition, a shorter retest period or shelf life than the period covered by long term data could be called for.
API Stability: Evaluation For products intended for storage in a refrigerator (no intermediate) Significant change at accelerated condition No extrapolation is allowed In addition, a shorter retest period or shelf life than the period covered by long term data could be called for. If significant change occurs within the first 3 months' accelerated testing, a discussion should be provided to address the effect of short –term excursions
API Stability: Evaluation Definition: re-test period The period of time during which the API is expected to remain within its specification, provided that the API has been stored under the defined conditions. After this period Re-tested for compliance with the specification and then used immediately. A batch of API can be re-tested multiple times and a different portion of the batch used after each re-test, as long as it continues to comply with the specification. For most substances known to be labile, it is more appropriate to establish a shelf life than a re-test period. Example: rifampicin
API Stability: Stability Commitments • Primary stability study commitment When available long-term stability data on primary batches do not cover the proposed re-test period. • Commitment stability studies The long-term stability studies on at least three production batches. To determine that the API remains and can be expected to remain within the re-test period in all future batches.
API Stability: Stability Commitments 1) A stability commitment is required when long term data does not cover the proposed re-test period. “The Applicant should undertake in writing to continue long-term testing of <INN of API> for a period of time sufficient to cover the whole provisional retest period and to report any significant changes or out-of-specification results immediately to WHO for the following batches : <Batch numbers, manufacturing dates, batch size, primary packing materials >”
API Stability: Commitments 2)A stability commitment is required when data was not provided on three production scale batches. “Since stability data on three production scale batches were not provided with the application, the remaining number of consecutive production scale batches should be put on long-term stability testing. Any significant changes or out-of-specification results should be reported immediately to WHO. The approved stability protocol should be used for commitment batches.”
API Stability: Commitments • Stability protocol should follow the same as primary batches but may change in batch numbers, batch size. Any differences in the stability protocols used for the primary batches and those proposed for the commitment batches should be scientifically justified. • In general, we do not request submission of the commitment results. But to report immediately for any OOS, OOT. The reports should be available for inspection. Therefore, a signed and dated commitment is requested and should be recorded. • When submitting post approval variations, e.g. extension shelf life, change in batch size, the data of commitment batches may be requested.
API StabilityStatements/Labelling • All containers should be clearly labeled with at least: • name of the material • batch number • expiry date or retest date • specified storage conditions • Name and address of the manufacturer (main generic G) • Recommended labeling statements provided in Appendix 3 of the New Guide.
Example #1API Re-test and Shelf-life Problem: The applicant has proposed a 12 month re-test period and a 48 month expiration period. They have provided data to support the re-test period, but not the shelf-life. Now what? Approach: Except in exceptional situations, the shelf-life is not required and is considered an extra assurance. Since a re-test period is defined, the applicant must re-test the API immediately prior to its use once the re-test period has been exceeded. The re-test period, which is supported by data, is approved.
Example #2No Accelerated Data Problem: Data is provided over the retest period at long-term conditions. No data is provided at accelerated conditions. The applicant argues that accelerated data is not necessary because long-term data covers the proposed retest period. Approach: Accelerated data is not only to support extrapolation, it is also to cover excursions outside the long-term storage conditions. Accelerated data is always required to support a retest or shelf-life period.
Example #3Extrapolation • 6 months at 40ºC/75% data: no significant change observed • 18 months data at 30 ºC75%, show little change and little variability. • What 's the maximum allowed retest period and storage condition? • X=18, the longest period allowed is up to 2X ( 36 months), but Not more than X + 12= 30 months
Common Deficiencies These deficiencies are commonly encountered and lead to questions and delays in approval of a re-test period: • Failure to state the size of the lots used in the trial. • Failure to describe clearly the packaging used in the trial and to confirm whether it is identical to the proposed packaging. • Failure to accumulate stability data on the required number of lots. • Failure to define accurately the temperature and humidity conditions applied during the trial. ±2◦C, ±5%RH
Common Deficiencies • Failure to fully describe test methods. • Failure to provide validation of analytical methods. • Expression of results as passes test or similar when a quantitative figure would be available. • Failure to include quantitative or semiquantitative determinations of the content of degradation products, or to provide only total content rather than values for individual impurities. • Use of an HPLC assay procedure to detect impurities without validation for the purpose.
Common Deficiencies • Failure to comment or conduct additional tests when there is a lack of mass balance between the formation of degradation products and the loss of the active substance. For example, are the assay procedures sufficiently specific? Is the API volatile? Is it adsorbed on to the container wall? • Failure to conduct additional tests to investigate the significance of obvious alterations in the characteristics of the product. For example a distinct change in the colour of the product may necessitate additional investigation for degradation products. • Failure to discuss any OoS or OoT results
Common Deficiencies • Failure to include information on the physical characteristics of the product during storage, such as particle size etc when considered critical attributes. • Failure to provide results from intermediate time stations to facilitate assessment of any trends in the parameters measured, when significant change is noted at accelerated conditions. • Attempting to extrapolate data obtained in the trial beyond reasonable limits.