1 / 1

Approaching a Universal Pneumatic Nebulizer Jerry Dulude (USA), Vesna Dolic and Peter Liddell (Australia), Glass Expansi

Tracey Cyclonic Spray Chamber With Helix. SeaSpray Concentric Glass Nebulizer With EzyFit And EzyLok. Approaching a Universal Pneumatic Nebulizer Jerry Dulude (USA), Vesna Dolic and Peter Liddell (Australia), Glass Expansion (www.geicp.com). PE OPTIMA 2100DV ICP-OES.

vian
Télécharger la présentation

Approaching a Universal Pneumatic Nebulizer Jerry Dulude (USA), Vesna Dolic and Peter Liddell (Australia), Glass Expansi

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Tracey Cyclonic Spray Chamber With Helix SeaSpray Concentric Glass Nebulizer With EzyFit And EzyLok Approaching a Universal Pneumatic Nebulizer Jerry Dulude (USA), Vesna Dolic and Peter Liddell (Australia), Glass Expansion (www.geicp.com) PE OPTIMA 2100DV ICP-OES VARIAN VISTA MPX AXIAL ICP-OES INTRODUCTION Glass Expansion currently designs nebulizers to accommodate the recommended gas pressures and flows of the various spectrometer manufacturers. However, it is desirable to design a single nebulizer that when run under high pressure conditions will generate a finer mist and more of it. In this study a nebulizer was designed to operate at 60psi, markedly higher than that of a standard nebulizer. This nebulizer was compared to the standard for a variety of performance parameters on two different ICP-OES systems. Figure 9: Effect of Pressure on Performance- Long-term Stability(2ml/min uptake) Inter-Nebulizer Variation Figure 4: Effect of Pressure on Performance- Short-term Stability(2ml/min uptake) Figure 7: Effect of Pressure on Performance Signal Intensity (2ml/min uptake) To determine the effects of subtle changes in parameters, it is necessary to first establish the inter-nebulizer variability within a given design. Figure 2 demonstrates the inter-nebulizer variability for a group of 5 different 60 psi nebulizers of the same configuration at two different uptake rates. Note that even though the uptake rate has been decreased by a factor of 5, emission intensity counts are decreased by only about 20 to 25%. This is due to the much higher efficiency produced at lower uptake rates. 30psi 60psi 30psi 60psi 30psi 60psi EXPERIMENTAL Figure 10: Effect of Pressure on Performance- Detection Limit (2ml/min uptake) Figure 8: Effect of Pressure on Performance- Short-term Stability(0.4ml/min uptake) Figure 5: Effect of Pressure on Performance- Long-term Stability(2ml/min uptake) Figure 2: Inter-Nebulizer Study Results (60psi) A Tracey™ Cyclonic spray chamber was used with a SeaSpray™ concentric glass nebulizer (both from Glass Expansion, Inc., Pocasset, MA and shown below in Figure 1). Standard conditions were used across the board on both a Varian Vista MPX and a Perkin Elmer Optima 2100. Both ICP-OES instruments were used with axial view for all lines. 30psi 60psi 30psi 60psi Figure 1: Sample Intro System DISCUSSION and CONCLUSIONS Figure 6: Effect of Pressure on Performance- Detection Limit (0.4ml/min) Figure 3: Effect of Pressure on Performance Signal Intensity (2ml/min uptake) Figure 2 illustrates that the high reproducibility of various nebulizers of the same design enables detection of differences between nebulizers of a different design. Figures 3 through 6 show the improvements provided by the 60psi design in terms of intensity, stability, and detection limit for the Varian Vista MPX. This improvement is duplicated for the same parameters on the Perkin Elmer 2100 (Figures 7 through 10). Although all studies were conducted at both 0.4 and 2.0ml/min uptake rates, a clear difference was not always revealed for both. Therefore, in some cases, data is shown for one or the other. We are currently Investigating further to determine the source of these anomalies. A pneumatic nebulizer operated at 60psi offers significant improvements in perfor- mance over the standard nebulizer for two different ICP-OES manufacturers and models. Future work will center on the improvement in performance at lower uptake rates and the ability of these nebulizers to handle high dissolved solids samples. 30psi 60psi

More Related