1 / 6

Preliminary Study of Possibility of HTS Use in ILC Extraction Quadrupole

Preliminary Study of Possibility of HTS Use in ILC Extraction Quadrupole. Ramesh Gupta Brookhaven National Laboratory. Why HTS Super-ferric Magnets?. This presentation is not intended to cover this topic.

vicky
Télécharger la présentation

Preliminary Study of Possibility of HTS Use in ILC Extraction Quadrupole

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Preliminary Study of Possibility of HTS Use in ILC Extraction Quadrupole Ramesh Gupta Brookhaven National Laboratory

  2. Why HTS Super-ferric Magnets? This presentation is not intended to cover this topic. Basically we are trying to find out if there is a region where HTS medium field magnets can be competitive in terms of “cost of ownership (capital + operation)” as compared to “water cooled copper magnets” and/or super-ferric magnets made with convention “Low Temperature Superconductors (LTS)”. HTS magnets offer several other benefits as well. • In case of RIA, HTS quadrupole for fragment separator region also turned out to be cheaper in cost as compared to water-cooled copper magnet. The original reason for choosing HTS was a better technical solution (higher gradient). • HTS quad operating at ~30 K was preferred over LTS to remove large energy (15 kW in first quad) economically at ~30 K rather than at ~4 K.

  3. Preliminary Investigation of HTS Quadrupole for ILC (QFEX4B-4E) • Design goals of this investigation: • Use 2nd generation HTS (YBCO). • Operate at 65 K or above (use sub-cool nitrogen or cryo-coolers). • Design with the conductor available today (improved performance would reduce conductor cost and coil size). • Warm iron compact design with low fringe field (seems to meet ILC spec). Revised 9 cm pole 40 cm outer radius HTS magnets would be more compact plus energy efficient as compared to water cooled magnets; and would allow larger temperature excursions as compared to LTS magnets. • Basic design parameters (as per slac-pub-1159, updated by C. Spencer): • Good field radius = 85 mm; Gradient ~11.8 T/m • Above quad is designed for a minimum pole radius = 90 mm; Gradient = 13+ T/m

  4. Preliminary Design Not good to go in machine, but good enough for proof-of-principle 9 cm minimum pole radius, 13 T/m Gradient, 40 cm yoke outer radius Gradient on axis (G/cm) Fringe field (G) on X-axis Jo = 50 A/mm2

  5. HTS Quadrupole For RIA Recently we completed a successful testing HTS R&D quadrupole for RIA (Rare Isotope Accelerator) The test also involved a 40+ minutes of stable operation at 30 K with a huge 25 W (5W/cm3 or 5MW/m3) heat load on coils.

  6. 77 K Performance of First and Second Generation HTS from ASC Conductor w = 4.35 mm t = 0.2 mm (2nd generation) 1st generation Higher Ic at 65 K 2nd generation HTS with nano-dots 1st generation Second generation HTS are new. Expect a significant improvement in performance and reduction in cost

More Related