R. Bonomi R. Kleindienst J. Munilla Lopez M. Chaibi E. Rogez

CASE STUDY 1: Group 1C. Nb 3 Sn Quadrupole Magnet. R. Bonomi R. Kleindienst J. Munilla Lopez M. Chaibi E. Rogez. CERN Accelerator School, Erice 2013. GOAL. LHC upgrade requires quadrupole magnets with larger apperture .

vilina
Télécharger la présentation

R. Bonomi R. Kleindienst J. Munilla Lopez M. Chaibi E. Rogez

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. CASE STUDY 1: Group 1C Nb3SnQuadrupole Magnet R. Bonomi R. Kleindienst J. Munilla Lopez M. Chaibi E. Rogez CERN Accelerator School, Erice 2013

  2. GOAL • LHC upgrade requires quadrupole magnets with larger apperture. • Design proposal for Nb3Sn superconducting quadrupole with 150 mm aperture for operation at 1.9 K. • Study includes coil design, magnetic and mechanical properties. CERN Accelerator School, Erice 2013

  3. COIL WIDTH • The magneticgradientdepends on thewidthofthecoil • Adding additional coilwidthleadstodiminishingrewards • A relativelythin design was chosenas a compromisebetweencostandgradient -> 2 coils of 10 mm width • Twolayerschosentoallowmorepossibilities in design forminimizingfielderrors 3 CERN Accelerator School, Erice 2013

  4. CABLE PARAMETERS t w 4 CERN Accelerator School, Erice 2013

  5. LOAD LINE • Loadline plottedforourconfiguration • Short sample and operational parameterscomputed • Higher fieldgradientpossiblewith(118 T/m vs. 83 T/m) • Temperaturestabilitymarginhigherby~3K CERN Accelerator School, Erice 2013

  6. COIL LAYOUT • Coil layout used to compensate higher order multipoles • Each sector used to cancel out next non-forbiddenorder CERN Accelerator School, Erice 2013

  7. MECHANICAL DESIGN • Mechanical Design shouldavoidtensile stress • Thinshellapproximationused(26%) • Forces computedusingformula: • Iron yokesupporting 90% ofIss • Collarthickness 20 mm for a maximum stress of 70 MPa • Thicknessofshrinkingcylinder12 mm forupto 100 MPa -> Useof Aluminium possible CERN Accelerator School, Erice 2013

  8. ISSUES

  9. ISSUES: YBCO vs. Bi2212 • Both are cuprites, the SC isconfinedtotheCuO plane, mechanism not fullyunderstood • In bothcases high criticalcurrentin singlecrystals, howeverseverlyloweredby grain boundries! • Bi2212, unlike YBCO canbeformedtoroundwiresusing power in tubeprocess • Compactionandheatinghave large impact on SC-properties, large parameterspacetooptimize CERN Accelerator School, Erice 2013

  10. ISSUES: SC COIL DESIGN • The block-coil geometry naturally suppresses extrinsic losses, which typically constitute ~half of all ac losses, which are reduced in the block-coil geometry by the aspect ratio of the cable, typically 10:1 • The simple equivalent block-coil design requires 20% less superconductor than the cosθ design of the same aperture and field strength. • Furthermore, one of the characteristics of the block-coil model is its scalability. After having studied the basic characteristics of a small aperture block coil magnets, an attempt could be made to design a large aperture magnet in a fast and efficient way by scaling up both the dimension of the aperture and the number of the blocks. CERN Accelerator School, Erice 2013

  11. ISSUES: ASSEMBLY PROCEDURE • Pre-stress isneededtobesurethatnotensilestresses will beapplied on thecoil • Pre-stress isusuallyloweredwhenthemagnetiscooled down • Enoughamountofpre-stress toremainatcompressivestateofstressesateveryoperationconditionisneeded. • As a generalrule, pre-stress shouldbeassmallasneededtoaccomplishthiscondition, plus somesafetymarginofsomeMpaastypicalvalue (0-30 MPa) CERN Accelerator School, Erice 2013