1 / 6

Matthew J. Major, PhD; Laurence P. J. Kenney, PhD; Martin Twiste, PhD; David Howard, PhD

Stance phase mechanical characterization of transtibial prostheses distal to the socket: A review. Matthew J. Major, PhD; Laurence P. J. Kenney, PhD; Martin Twiste, PhD; David Howard, PhD. Aim

wedna
Télécharger la présentation

Matthew J. Major, PhD; Laurence P. J. Kenney, PhD; Martin Twiste, PhD; David Howard, PhD

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Stance phase mechanical characterization of transtibial prostheses distal to the socket: A review Matthew J. Major, PhD; Laurence P. J. Kenney, PhD; Martin Twiste, PhD; David Howard, PhD

  2. Aim • Introduce framework for studying prosthesis design, including Amputee Independent Prosthesis Property (AIPP) characterization, human performance/gait simulation studies, and detailed design. • Relevance • Most studies on effects of prosthesis design on amputee performance compare different products’ biomechanical and physiological effects, without characterizing AIPPs. • This approach only indicates relative performance, but cannot explain why one prosthesis performs better than another.

  3. Framework for studying prosthesis design.

  4. Methods • Literature search • Primary: MEDLINE/EMBASE, 1970 to July 2011. • Secondary: Using references in primary search to include journals not indexed in MEDLINE/EMBASE. • Exclusion criteria: • Only reported fatigue testing of components. • Tested prostheses with socket and shank constructed of single material. • Tested prostheses capable of internal power-generation. • Tested components from transfemoral amputee gait studies. • Written in language other than English.

  5. Results • Primary search: • 443 MEDLINE articles, 410 EMBASE articles. • 36 satisfied criteria. • 5 relevant review papers identified. • Sagittal plane behavior of passive transtibial prosthesis during gait can be described by following AIPPs: • Two-dimensional roll-over shape,alignment of roll-over shape, elastic properties, damping properties, and mass properties.

  6. Conclusion • Proper AIPP characterization essential to research stage of design approach. • Properties of existing prostheses should be measured independent of amputee (AIPPs) before in vivo performance testing. • Better understanding of correlations between AIPPs and their effects on gait can be developed through studies measuring both AIPPs and gait performance, with amputees grouped by motor capacity. • Desirable AIPPs could then become inputs to prosthesis design process.

More Related