1 / 11

Comparing LabVIEW 2011 with 8.6: New Features and Benefits for FRC Development

This document provides a detailed comparison between LabVIEW 8.6.1 and LabVIEW 2011, particularly focusing on enhancements relevant to the FRC environment. Key improvements include VI snippets for easier code sharing, recursion support, an upgraded probe watch window, enhanced diagram cleanup features, and the addition of new 2D and 3D graph functionalities. Other notable features include better performance, improved real-time deployment, and various new capabilities that enhance usability and code structure. These changes significantly benefit FRC teams in robot programming.

woods
Télécharger la présentation

Comparing LabVIEW 2011 with 8.6: New Features and Benefits for FRC Development

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. LabVIEW 2011 Versus 8.6 Doug Norman National Instruments January 6, 2012

  2. LabVIEW FRC 2012 • FRC Edition 2011 used LabVIEW 8.6.1 Pro • FRC Edition 2012 uses LabVIEW 2011 Pro • Many new features from 3 versions: • LabVIEW 2009 • LabVIEW 2010 • LabVIEW 2011

  3. New Features from LabVIEW 2009 • VI Snippets • Recursion • Probe Watch Window • Quick Drop additions • New icon editor • Partial Diagram Cleanup • Parallel For Loops • Timing sources • Command Line compare • New 2D and 3D graphs

  4. VI Snippets • Save a section of diagram code into a .png file • Edit>>Create VI Snippet from Selection • The image shows a picture of the code and contains the actual code • Makes it easy to share code • Just drag the .png file onto a block diagram

  5. Partial Diagram Cleanup • Select wires and objects • Edit>>Clean Up Selection • OrCtrl+U • Code within structures can be excluded • Right-click structure >> Exclude from Diagram Cleanup

  6. Recursion • Configure a VI to be reentrant • Select Share clones between instances • Drag the icon of the VI onto its own block diagram • LabVIEW Real-Time supported, but not deterministic

  7. New Features from LabVIEW 2010 • Versioned VI Snippets • Owned Labels on wires • Export Graph/Chart data • New T and F constants • Undo buffer from 8 to 99 • VI Scripting • Cluster constant as icon • Quick Drop - replace • Rewire Conn Pane • Merge Error is growable • Packed Project Libraries • InliningSubVIs

  8. New Features from LabVIEW 2011 • Performance & stability • Improved RT deployment • Conn Pane always shows • Create subVI improvements • Booleans accept error wire • Undo after save • Ignore all subVIs • Silver controls • Type def from diagram • Align, Distribute wires

  9. Create SubVI Improvements • 4 x 2 x 2 x 4 connector pane by default • Error terminals in lower corners • Refnum or class terminals in upper corners • Controls aligned on left side of front panel • Indicators aligned on right side of front panel

  10. Conclusion • Many new features between LabVIEW 8.6.1 and LabVIEW 2011 • Many are useful for FRC Questions?

More Related