1 / 19

Gas Detector Tubes

Gas Detector Tubes. Low-cost Detection of Hazardous Gases & Vapors. DETECTOR TUBES. Detector Tube Product Line - Manufactured by Kitagawa in Japan. Disposable glass tubes used to identify a targeted gas with in a specified measuring range when fixed amount of air is pumped through it. Simple

Télécharger la présentation

Gas Detector Tubes

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Gas Detector Tubes Low-cost Detection of Hazardous Gases & Vapors

  2. DETECTOR TUBES • Detector Tube Product Line - Manufactured by Kitagawa in Japan. • Disposable glass tubes used to identify a targeted gas with in a specified measuring range when fixed amount of air is pumped through it. • Simple • Inexpensive • Easy to use • ± 25% Accuracy

  3. Why Use Sensidyne • Outstanding customer service. • Finest technical support in industry. • Excellent on time delivery record. • Full line quality product. • Refrigerated storage for longer shelf life. • Shatter proof tubes.

  4. Model AP-20S • Single-stroke operation • Ergonomically designed • Lightweight and corrosion-resistant • Piston-type volumetric pump assures accuracy every time • Fail-safe handle locks in two positions (50 ml or 100 ml) • Flow finish indicator.

  5. Detector Tube Analyzer Layer Gas Flow Arrow Sealed Tube Pre-Cleanse Layer Plug Plug Sealed End

  6. Taking A Sample

  7. Taking A Sample Continued

  8. System Specifications • Accuracy: ± 25% of Reading • Temperature: 0 to 40°C (32 to 104°F) • Humidity: 10 to 90% RH • Shelf Life: Two Years (Most Tubes)

  9. Field Leak Check

  10. Field Leak Check Continued

  11. Inter-Brand Compatibility • In general, mixing brand components is not recommended • Some combinations can cause significant accuracy loss • Some brands are made to higher quality standards than others • Sensidyne offers a Pump Swap for pumps from competitors

  12. Pump Swap Program

  13. Tube Selection Guide

  14. Tube Selection Guide

  15. Deluxe HazMat Kit

  16. Tube NO. 131 COLOR CHART

  17. Tube NO. 186B Color Chart

  18. Smoke Tubes Manual Fit Test Part No. 5100 RespiFit™ Fit Test No. 7013304-1

  19. Thank You www.Sensidyne.com 800-451-9444 / 727-530-3602