1 / 26

Low Energy Building Design 2010

Low Energy Building Design 2010. Presentation 2 TEAM ZERO Arnaud Gibert Bintou Ouedraogo Danny Tang Naeema Hafeez Paul Dupuy. Aim. Is to design 3 housing types which will form a 20 dwelling net zero carbon community, located in rural Ayrshire Designed to Code Level 5 or better

yana
Télécharger la présentation

Low Energy Building Design 2010

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Low Energy Building Design 2010 Presentation 2 TEAM ZERO Arnaud Gibert Bintou Ouedraogo Danny Tang Naeema Hafeez Paul Dupuy

  2. Aim • Is to design 3 housing types which will form a 20 dwelling net zero carbon community, located in rural Ayrshire • Designed to Code Level 5 or better • To be an exemplar of sustainable, low energy design for the future developments

  3. Tasks

  4. Passive House Standard • Exterior shell insulated to achieve a u-value not exceeding 0.15W/m2 • U-value between 0.11-0.15 W/m2 • Making full use of solar energy • Southern orientation and shade considerations • Energy Efficient window glazing and frames • U-value should not exceed 0.80W/m2 for both the glazing and frame of window • Total energy demand for space heating and cooling should be less than 15kWh/m2/yr

  5. Study of Materials • Structural Frame of Building • Steel • High in embodied energy • Rarely ever used in construction of homes • Omitted from selection • Concrete • High in embodied energy • Heavyweight material • Used mainly for larger buildings • Should be avoided • Timber-final choice • Low in embodied energy • Can be locally sourced from site • Energy efficient material

  6. Study of Materials • Insulation materials • Recycled newspaper • Hemp • Straw Bales • Sheep’s wool • In the end it was decided that insulation will not be required because the material we are using are straw bales and therefore act as a load bearing wall and provide insulation • Walls • Timber cladding • ThermoPlan Ziegel Blocks • Excellent thermal performance • Finished construction airtight • Low wastage • Very low in embodied energy- • However, they have to be transported from Germany- increase the embodied energy of the material • Rammed Earth

  7. Straw Bales-Final choice • 450mm thick can be 300mm • Very Low in embodied energy- 0.24MJ/kg (University of Bath) • Low u-value 0.13W/m2 • Very high level of insulation • Windows and Frame • Triple-glazing windows with Timber frame • Improved energy efficiency • Exterior noise reduced • U-value for triple glazing is 2.0W/m2 • U-value for triple-glazing with multiple low emissivity coatings and Xenon filled = 0.4W/m2

  8. 2 Bedroom Design

  9. 3 Bedroom Design

  10. 4 Bedroom Design

  11. Energy Demands • Passive house standards : • Space heating : 15 kWh/m²/year • Hot water : 9 kWh/m²/year • Appliances : 16 kWh/m²/year • Ventilation : 2 kWh/m²/year • Total habitable surface : 2640 m² • Total thermal requirements : 9.7 kW (average) • Total electrical requirements : 7 kW (average)

  12. Solar • Surface available : • 524 m² for the community. • Power density : • 152 W/m²

  13. Thermal • Schuco Sol Premium line • Thermal output : 2kW • Surface : 2.69 m² • Total surface for the community : 60 m² • Using power density for calculation • Total output (Community): 10kW

  14. Photovoltaic • Solar century C21e • Electrical output : 143 W/m² • Module efficiency : 14.9 % • Surface for the community :450 m² • Using power density for calculation • Total output : 10kW

  15. CHP • Yanmar : CP10VB1 • Electrical output : 9.9 kW • Thermal output : 16.8 kW

  16. Ventilation • Ventilation system: • Mechanical Ventilation mixed with passive natural ventilation • Displacement ventilation • Heat recovery system • Heat loss 7kWh/m2 per year

  17. Ventilation • Ventilation requirement: • Excellent outdoor air quality -> 0 decipol • Indoor air quality B (20% PD) -> 1.4 decipol • Pollution level from materials 0.1 olf/m2 • Pollution from occupant 1olf/pers • Expected ventilation effectiveness 1.5 • Required Ventilation • 10 x Pollution load/(( Indoor AQ – Outdoor AQ)x effectiveness) -> 0.67 l/s per m2 or 78l/s, 84 l/s and 112l/s for the 3 houses

  18. Ventilation • Ventilation- Energy consumption: • 120W for the 2 Bedrooms , 150W for the 3 and 200W for the 4 • 12h/ days, 250 days per year -> 360kWh/year for the 2 bedrooms house -> 450kWh/year for the 3 bedrooms house -> 600kWh/year for the 4 bedrooms house

  19. Lighting • Lighting Requirement: • Kitchen, Bedrooms, Study, Bathroom 300 lux • Living room, Dinning Room 200 lux • Corridors 100 lux • Required lighting = Required illuminance x Area / lamp lumen output x utilization factor

  20. Lighting • Lighting System: • Natural Lighting • Windows on the south • Solar tubes on the north • Luminaries for the night or cloudy days • Fluorescent Lamp • Compact

  21. Lighting • Lighting- Energy Consumption: • 350W for the 2 bedrooms • 420W for the 3 bedrooms • 500W for the 4 bedrooms • 10h/days in winter • 8h/days in spring and autumn • 6h/days in summer -> 650kWh/year for the 2 bedrooms house -> 850kWh/year for the 3 bedrooms house -> 1,000kWh/year for the 4 bedrooms house

  22. Water • Water requirement: • 100l/day per person • Water system • Grey water recycling system

  23. Transportation • Alternative for cars • Cycling, rollerblading and walking • Public Transports • Bus stop • Electric Cars • Advantages: • Price of electricity • Little noise • Solar Parking • Solar Panel

  24. Transportation • Blue Car • Bats cap Lithium Metal polymer battery • Life span 10 years • Entirely recyclable • Recharging time: 4 hours • Average autonomy: 25o km

  25. Plan of Work • Use ESP-r model • More details drawings • Model ventilation and Lighting in more detail • Homer • Calculate embodied energy of materials • Cost • Transportation- more detail

  26. Any Questions??

More Related