Broadband Powerline (BPL) Interference into VDSL2 on Drop Lines: Measurements and Analyses

Broadband Powerline (BPL) Interference into VDSL2 on Drop Lines: Measurements and Analyses. Ken Kerpez, Telcordia Technologies pursuant to work supported by AT&T. kkerpez@telcordia.com 732 699-2234. Coupling Measurements Set-Up. POWER. PHONE. Twenty-five coupling measurements BPL – VDSL2.

yasuo
Télécharger la présentation

Broadband Powerline (BPL) Interference into VDSL2 on Drop Lines: Measurements and Analyses

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Broadband Powerline (BPL) Interference into VDSL2 on Drop Lines: Measurements and Analyses Ken Kerpez, Telcordia Technologies pursuant to work supported by AT&T kkerpez@telcordia.com 732 699-2234

  2. Coupling Measurements Set-Up POWER PHONE

  3. Twenty-five coupling measurementsBPL – VDSL2 Vary with BPL termination impedences, drop wire type, drop length

  4. VDSL2 Profile 8a Bit Rates Interference from -60 dBm/Hz BPL,80 ft exposure length, From well-established VDSL2 simulations Upstream VDSL2 Downstream VDSL2 Upstream bit rates of VDSL2 lowered 40% on average Downstream bit rates of VDSL2 lowered 14% on average

  5. Other measurements • BPL emissions • BPL assumed -60 dBm/Hz, flat, on power drop line • Exceeded FCC part 15 limit up to about 10 dB in some cases • Live BPL line coupling into live VDSL line • Up to 21 percent decrease in VDSL bit rate • Measured in a lab, 30 ft exposure • VDSL1

  6. Ways of mitigating impact 1. Lower power VDSL2 Profile 8a or 12a downstream bit rates averaged over the 25 canonical measured couplings, Flat BPL transmit PSD varying from -50 dBm/Hz to -80 dBm/Hz

  7. Ways of mitigating impact 2. Avoid low frequencies VDSL2 Profile 8a or 12a downstream bit rates averaged over the 25 canonical measured couplings. Lowest BPL band-edge varying from 1.7 MHz to 8 MHz.

  8. Approaches to mitigate impact from BPL into VDSL2 • Define transmit PSD spectral mask • Use more advanced BPL transmit PSD shaping ? • Optional VDSL compatible transmit mode ? • when needed, when nearby VDSL2 detected, etc.