Superresolution in Fluorescence and Diffraction Microscopies with M ultiple I lluminations

Superresolution in Fluorescence and Diffraction Microscopies with M ultiple I lluminations. - Jules Girard -. 2 December 2011. Introduction : Imaging with optics and resolution. Imaging device. Parameter of interest. Probing function. Detector. FT. Low-pass filter.

Télécharger la présentation

Superresolution in Fluorescence and Diffraction Microscopies with M ultiple I lluminations

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Superresolution in Fluorescence and Diffraction Microscopies with Multiple Illuminations - Jules Girard - 2 December 2011

  2. Introduction : Imaging with optics and resolution Imaging device Parameter of interest Probingfunction Detector FT Low-passfilter

  3. Introduction : Extend resolution with illumination kx → ky By using multiple and inhomogeneous illuminations, we can shift high frequency parts of the object spatial spectrum into the passband defined by the psf kx kx More generally : = W. Lukosz and M. Marchand, OpticaActa10, 241-255 (1963). W. Lukosz, JOSA 56, 1463 (1966). ky ky

  4. Introduction : Reconstruct a super-resolution image • Inversion → numerical data processing 2 cases is known is unknown • Non-linear inversion • Findboth and • with the use of constraints • « Direct » inversion • withanalyticalapproach

  5. Presentation Outline = Optical Diffraction Tomography II. Structured Illumination Fluorescence Microscopy

  6. I. Optical Diffraction Tomography

  7. II. Optical Diffraction Tomography Fourier Space = 0 for lateral frequencies > Wemeasure : (Sample dielectric permittivity contrast) (Total internal electric field) Objective • Reconstruct : quantitative microscopy of unstained sample • ≠ illuminations → ≠ → access to ≠ parts of E Wolf, Optics Communications 1, 153-156 (1969). V Lauer, Journal of Microscopy 205, 165-76 (2002).

  8. II. Optical Diffraction Tomography • Illumination with « plane waves » under ≠ incidences • Measurecomplex values of Experiment (G. Maire, F. Drsek, H.Giovannini) CCD • Calibration and normalization • → Phase modulator • Inversion : ) → Laser (λ=633nm) Sample

  9. II. Optical Diffraction Tomography 2. 1. • Low :Born Approximation • is diffraction limited→ Abbe limit = • High : Multiple Scattering Regime • depends on object and illumination • isnot diffraction limited → resolutionimprovement? ( ?)

  10. II. Optical Diffraction Tomography simulations z air • λ = 633 nm • Abbe limitwith NA = 1.5 • → 211 nm 50 nm 25 nm x 50 nm glass 50° Low High (Ge) = 10-2 = 28.8 < !

  11. II. Optical Diffraction Tomography Experimental validation z • Germanium rods • TIRF configuration (10 angles) • NA = 1.3 • → Abbe limit : 245 nm air 50 nm 25 nm x 50 nm glass (A. Talneau – LPN) 0,5 Z (µm) 0 0,5 Z (µm) 0 9/27

  12. II. Optical Diffraction Tomography • Conclusion • We achieved quantitative reconstruction of the permittivity map of unstained sample even with a multiple scattering regime • Multiple scattering : drawback way to improve the resolution of ODT far beyond diffraction limit 10/27

  13. II. Structured Illumination in Fluorescence microscopy on 2D samples

  14. III. Structured Illumination Microscopy in Fluorescence (2D) Objective Tube Lense CCD (fluorescence density) (fieldintensity) (2D and 1D) 11/27

  15. III. Structured Illumination Microscopy in Fluorescence • Use periodic pattern → R. Heintzmann and C. Cremer, SPIE, pp. 185-196.(1998) Mats G L Gustafsson, Journal of Microscopy 198, 82-7 (2000). kx • Requirements for illumination pattern : • Accurate translation→ needed for discrimination of the 3 copies • High contrast → higher SNR (no dim for shifted copies of ) ky

  16. III. Structured Illumination Microscopy in Fluorescence • Limit : Illumination pattern isdiffraction limited: • = : twicebetterthanclassical WF • How canwereachhigherfrequencies ? • Use of non-linearities :→ • (R. Heintzmann et al., JOSA A, 19, 2002 & M G L Gustafsson, PNAS, 102, 2005) • Get below diffraction limit(surface imaging) • High index substrate→ limitedn and/or absorption • Nanostructured deviceswithplasmonics • → fieldbound to the structure + difficulties to cover a large area

  17. III. Structured Illumination Microscopy in Fluorescence Grating assisted Structured Illumination Microscopy z=0 • Dielectric resonant grating ≈ 2D waveguide + 2D sub-λgrating a-Si layer @ 633nm Glass coverslip @ 633nm • Hexagonal geometry : 6 equivalent orientations → near isotropic resolution • Design optimization→numerical simulations

  18. III. Structured Illumination Microscopy in Fluorescence (J. Girard, A. Talneau, A. Cattoni LPN – CNRS) Gratings fabrication process 1. aSi deposition (PECVD) 2. Grating patterning (e-beam + RIE) 3. Planarization (A. Cattoni) A. Cattoni, A. Talneau, A-M Haghiri-Gosnet, J. Girard, A. Sentenac (oral presentation, MNE 2011)

  19. III. Structured Illumination Microscopy in Fluorescence Excitation modes of the grating substrate 2 beams excitation 1 beam excitation right left

  20. III. Structured Illumination Microscopy in Fluorescence Experimental setup • Control of orientation, phaseand incidence angle on the substrate (65°) Objective (Oil, NA 1.49) Dichroïc Mirror

  21. III. Structured Illumination Microscopy in Fluorescence Grating characterization : SNOM measurements 1 beam excitation (GeoffroyScherrer, ICB, Dijon) Stretched fiber 65° GridShifting High Frequency Pattern from the Grating simulation Theoretical simulation z= Figure IV.4.1‑1  Montage expérimental pour la mesure en champ proche optique

  22. III. Structured Illumination Microscopy in Fluorescence Grating characterization : Far field fluorescence measurements • 2 beams excitation : Low frequency component of the intensity pattern • WF Fluorescence observation with ~homogeneous layer of fluorescent beads

  23. III. Structured Illumination Microscopy in Fluorescence • Our manufacturedgratingscanproduce a grid of light with • 180 nm period (λ/3.5) (down to 147 nm, λ/4.3 with alternative design) • a highcontrast • The possibility to shift its position • According to , a final resolutionof up to 87 nm couldbereachedatλ =633 nm! = • Howeverweneed to know the illumination pattern for inversion procedure

  24. III. Structured Illumination Microscopy in Fluorescence “Blind” SIM Inversion unknowns: • Iterativeoptimizationof estimates of and through minimization of a costfunction: … (Emeric Mudry & Kamal Belkebir) +1 equations 21/27

  25. III. Structured Illumination Microscopy in Fluorescence Experimental validation • Observation of fluorescent beads (Ø 90nm) immersed in glycerinwithclassical SIM Our Result WF image Deconvolution of the WF image Optimized « analytical » algorithm Inversion by Pr. R. Heintzmann 22/27

  26. Measurement Simulation • III. Structured Illumination Microscopy in Fluorescence Speckle illumination • Speckle pattern is a perfect candidate for SIM withour ‘blind’ inversion algorithm 2. Known average illumination 1. Contains every accessible frequencies 3. Experiment far simpler than standard SIM 23/27

  27. III. Structured Illumination Microscopy in Fluorescence Speckle illumination : simulations speckles speckles object WF image Deconvolution = Deconvolution = N ≈ 80 One measured image Photon budget : average of 130 photon/pixel/image Reconstructed = 24/27

  28. III. Structured Illumination Microscopy in Fluorescence Speckle illumination : experimental results RabbitJejunum slices (150nm thick) (Cendrine Nicoletti, ISM, Marseille) TEM image of a similarsample WF image Reconstructed image from 100 speckle illuminations Deconvolution of WF image 25/27

  29. General Perspectives • Optical Diffraction Tomography : • Extend to 3D samples • Use other configuration (gratingsubstrate, mirrorsubstrate…) II. Structured Illumination in Fluorescence Microscopy • Grating-assistedSIM : • Make super-resolved images of real samples : use a priori information for inversion procedure • Speckle illumination : • Extend to 3D samples 27/27

  30. III. Structured Illumination Microscopy in Fluorescence • Conclusion • SIM with unknown illumination patterns • Extension ofSIM to the use of randomspeckle patterns • Not effective yet for grating-assisted SIM (inhomogeneousaverage illumination) 26/27

  31. Thanks… • Geoffroy Scherrer • Anne Talneau • Andrea Cattoni Eric Le Moal Kamal Belkebir Guillaume Maire Emeric Mudry Anne Sentenac • The whole MOSAIC team for advices, seminars, discussions, equipment, facilities…

  32. Thank you for your attention

  33. II. Optical Diffraction Tomography • NA = 0.7 (used up to 0.53 only for illumination) • → Abbe limit : 500 nm (450nm for full NA) z air 100 nm 110 x 300 nm AFM profile Si Reconstructed profile (linear inversion) Reconstructed map Reconstructed profile

  34. II. Optical Diffraction Tomography Multiple scattering and resolution Simulation of () =() for a plane wave illumination (incidence 50°) 100nm = 10-2 = 2(b)= 7 (c) = 14 Modulation of for the object 2 : 25nm = 28.8 (Germanium)

  35. III. Structured Illumination Microscopy in Fluorescence Grating assisted SIM : getting some images • Problem with inversion : Intensity pattern is not perfectly known • Speckle algorithmis not able to retrievefrequencies > • Add of a priori information (rough orientation and frequencies)