1 / 46

Electricity

Electricity. Part 4: Power Plants, Distribution and Cooling,. Electrical Power Generation. Motor External energy runs current through wire loop in magnetic field. Force on current-carrying wire causes torque. Loop rotates. Use rotating loop to move things. Electrical Power Generation.

zeal
Télécharger la présentation

Electricity

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Electricity Part 4: Power Plants, Distribution and Cooling,

  2. Electrical Power Generation • Motor • External energy runs current through wire loop in magnetic field. • Force on current-carrying wire causes torque. Loop rotates. • Use rotating loop to move things.

  3. Electrical Power Generation • Generator • Motor with input and output switched • External energy mechanically rotates wire loop in magnetic field. • Electric charges (in wire) move in magnetic field. • Magnetic force pushes charges through wire (current).

  4. Generators • Basically a motor used backwards. • Instead of running current through the loop to get the shaft to rotate, rotate the shaft with a heat engine, water wheel, or windmill to get electrical current. • This is what is done in essentially all power plants.

  5. Electrical Power Generation in the U.S.

  6. Electrical Power Generation in the U.S. • Fossil fuels 67% • Renewables 11.6% (Hydroelectric 7%) • Nuclear 19%

  7. Typical Coal Fired Power Plant

  8. Power Distribution

  9. Long distances, use very high voltage: up to 750,000 Volts. • For shorter distances use ~50,000 Volts • Locally step down to wall voltage • Use TRANSFORMERS to change voltages either up or down.

  10. Advantage to High Voltage Transmission • Minimizes losses in power lines • Transmitted power is P = IV. If V is high, then I can be low. • Losses in line are Ploss= I2R = V2/R • Lower losses high voltage transmission

  11. Current for 3 W power line and 50,000 V transmission of 1 x 109 W • 200 A • 2000 A • 20,000 A • 200,000 A

  12. Loss for 3 W power line and 50,000 V transmission of 1 x 109 W • 6000 W • 6 x 104 W • 1.2 x 107 W • 1.2 x 109 W

  13. Current for 3 W power line and 500,000 V transmission of 1 x 109 W • 200 A • 2000 A • 20,000 A • 200,000 A

  14. Loss for 3 W power line and 500,000 V transmission of 1 x 109 W • 6000 W • 6 x 104 W • 1.2 x 107 W • 1.2 x 109 W

  15. Case 1 V = 50,000 V This is more than we have, i.e. all our power is lost in transmission. Case 2 V = 500,000 V Here we only lose 1.2% of total power in transmission Example: Assume Rline= 3 , and P =1GW

  16. We only want to go short distance without much power at low voltages. • Transformers make it possible to raise and lower voltages with essentially no power loss. • This is the main reason we use AC power.

  17. Why do power companies use high voltages to transmit electric power over long distances? • To increase current in the power line • To decrease resistance in the power line • To reduce transmission losses • To keep squirrels and children away from power lines.

  18. Transformer

  19. According to Faraday’s Law, we may induce a voltage in a loop of wire immersed in a magnetic field by • Changing the area of the loop • Changing the strength of the magnetic field passing through the loop • Changing the orientation of the loop with respect to the magnetic field • All of the above

  20. What is the primary advantage of AC electricity over DC electricity? • It is safer • It is more reliable • We can easily change the voltage • It has more groovitude

  21. Cooling the plant. • We have to dispose of at least as much energy as we generate. (Power plants do not operate above 50% efficiency due to the 2nd law.) • Usually remove the waste heat with a continuous supply of water. • Question: How much water do we need?

  22. Cooling the plant. • What rate of water flow per megawatt of electricity generated do we need to cool a power plant? • Volume/time or mass/time (l/s or kg/s) • We will allow the water temperature to raise 7C

  23. Cooling the plant.

  24. Cooling the plant.

  25. Cooling the plant. • m/t is mass flow rate • To convert to volume flow rate use the density of water (kg/liter)

  26. Rate of water flow per megawatt • 34.1 l/s • 341 l/s • 3410 l/s • 341000 l/s

  27. Estimate the amount of water per megawatt • Assume we only want the water to raise 14F (7C).

  28. For 1 MW this is easy, but a typical power plant is 1000 MW. • To keep the temperature of the water from rising more than 14F on a 1000 MW = 1GW plant we would need approximately 9000 gallons per second. (Almost 800 million gallons per day.) (Approximately 6000 swimming pools per day.) • To keep the temperature for rising only ~5F we would need ~3 time as much water.

  29. Total freshwater runoff in the US is approximately 1200 billion gallons per day (this includes floods) • Electrical plants need approximately 400 billions of gallons per day.

  30. US Water Usage

  31. Methods of Cooling • Once through cooling: Requires a good size river OR a good size reservoir. • Least expensive method

  32. Infrared imaging of the power plant near Joliet

  33. Wet Cooling Tower • Extremely large towers 400 ft high and 400 ft across. • ~2% of water passing through evaporates, approximately 225 gallons per second. • Enough water to cover 1mi2, 1 in deep in water every day.

  34. Shape enhances natural air flow

  35. Vortex engine powered by excess heat

  36. Dry Cooling • Used in places without access to large supplies of water. • Much more costly than once through or wet cooling. • Looses efficiency if ambient temperature much above 90F. • Sort of like a big car radiator.

  37. Since 1977 power plants have been required to dispose of waste heat without directly dumping it into the aquatic environment. • Must construct cooling ponds or towers.

  38. Effects of Increased Water Temperature • Amount of oxygen dissolved in water decreases with temperature • Most fish simply can't stand warm water and/or low levels of dissolved oxygen.

  39. Increased rate of chemical reactions • Changes in reproduction, behavior, and growth patterns throughout the food chain. • Long term damage to natural bodies of water.

  40. Preferred Temperature Ranges for Fish

  41. Stratification of lake in the summer

  42. In the winter the top layer becomes colder and sinks to the bottom • This take oxygen rich water down and brings up nutrient rich water. • A power plant doesn’t allow this mixing to happen for as long. • Bottom dwelling animals have less oxygen • Discharge water from the bottom is rich in nutrients (Nitrogen and phosphorus) that stimulate algae and plant growth

  43. This can cause a mat of algae (green scum) on the surface that is toxic to many species. • Dead algae sinks to bottom and is decomposed using up even more of the oxygen at the bottom. • This can eventually lead to the “death” of the lake.

  44. Eutrophication • The process in which a body of water is enriched by the addition of extra nutrients , stimulating the growth of algae

More Related