OIL BURNERS

OIL BURNERS. R 2000 series. R 2000 burners. control box 554 SE. CONTROL BOX 554. TR. ST. PH. N. +. M. -. Valve coil starting:30V; 280mA running:3V; 30mA. Valve coil: 100 . Ignition transformer 20 kHz 8 kV 10 mA 40W. 1 A 800 VL input: 48 AC output: 72 DC.

ziya
Télécharger la présentation

OIL BURNERS

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. OIL BURNERS R 2000 series

  2. R 2000 burners control box 554 SE

  3. CONTROL BOX 554 TR ST PH N + M -

  4. Valve coil starting:30V; 280mA running:3V; 30mA Valve coil: 100 Ignition transformer 20 kHz 8 kV 10 mA 40W 1 A 800 VL input: 48 AC output: 72 DC CONTROL BOX 554 TR Electrical supply: 230 V±10% fuse 6A 250V L1 ST PH Photoresistence sensibility: 2 lux (starting) 3 lux (running) Motor pack 35 90W or pack 52 150W Pre-purge timer: 12’’ by a capacitor 22µF and a resistence 1M N Amplifier Safety relais (bimetallic) + Safety relais (bimetallic) M - Remote lock-out signal 230 V; max 0.1A Internal relais 12V

  5. CONTROL BOX 554 start up procedure: pre-purge TR ST PH N + M -

  6. CONTROL BOX 554 start up procedure: pre-purge TR ST PH N + M -

  7. CONTROL BOX 554 start up procedure: pre-purge TR ST PH N + M -

  8. CONTROL BOX 554 start up procedure: pre-purge TR ST PH N + M -

  9. CONTROL BOX 554 start up procedure: pre-purge TR ST PH N 72V DC 52 V AC + M - Timer is supplied (12”)

  10. CONTROL BOX 554 start up procedure: ignition TR ST PH N + M -

  11. CONTROL BOX 554 start up procedure: ignition TR ST PH N + M -

  12. CONTROL BOX 554 start up procedure: ignition TR ST PH N + M -

  13. CONTROL BOX 554 start up procedure: ignition TR ST PH N + M -

  14. CONTROL BOX 554 start up procedure: ignition TR ST PH N + M -

  15. CONTROL BOX 554 start up procedure: ignition TR ST PH N + M -

  16. CONTROL BOX 554 start up procedure: ignition TR ST PH N + M -

  17. CONTROL BOX 554 start up procedure: ignition TR ST PH N + M -

  18. CONTROL BOX 554 start up procedure: running TR ST PH N + M -

  19. CONTROL BOX 554 faults: no flame at ignition TR ST PH 280 mA N 280 mA at bimetallic relais + M -

  20. CONTROL BOX 554 faults: no flame at ignition TR ST PH N + M -

  21. CONTROL BOX 554 faults: no flame at ignition => lock-out TR ST PH N + M -

  22. CONTROL BOX 554 faults: light into the chambre (or short at photoresistence) TR ST PH N + M -

  23. CONTROL BOX 554 faults: light into the chambre (or short at photoresistence) TR ST PH N + M -

  24. CONTROL BOX 554 faults: light into the chambre (or short at photoresistence) continous pre-purge TR ST PH N + M -

  25. CONTROL BOX 554 faults: valve coil interrupted : continous pre-purge TR ST PH N Timer is not supplied + M -

  26. CONTROL BOX 554 faults: Short at Darlington R3381 by Texas TR ST PH N + M -

  27. CONTROL BOX 554 faults: Short at Darlington R3381 by Texas TR ST PH N + M -

  28. CONTROL BOX 554 faults: Short at Darlington R3381 by Texas TR ST Immediate change of position PH N + M - 2A at bimetallic relais

  29. CONTROL BOX 554 faults: Short at Darlington R3381 by Texas TR ST PH N + M -

  30. CONTROL BOX 554 faults: Short at Darlington R3381 by Texas Immediate lock-out TR ST PH N + M -

  31. OIL BURNERS R 2000 series

  32. OIL BURNERS CONTROL BOX SERIES 555 SE

  33. CONTROL BOX 555 SE TR ST PH N + PTC M -

  34. Valve coil starting:30V; 280mA running:3V; 30mA Valve coil: 100 Ignition transformer 20 kHz 8 kV 10 mA 40W 1 A 800 VL input: 48 AC output: 72 DC CONTROL BOX 555 SE TR Electrical supply: 230 V±10% fuse 6A 250V L1 ST PH Photoresistence sensibility: 2 lux (starting) 3 lux (running) Pre-purge timer: 12’’ by a capacitor 22µF and a resistence 1M Motor pack 35 90W or pack 52 150W N Amplifier Safety relais (bimetallic) Pre-heater 55W + Safety relais (bimetallic) M - Remote lock-out signal 230 V; max 0.1A Internal relais 12V

  35. CONTROL BOX 555 SE start up procedure: pre-heating TR ST PH N + M -

  36. CONTROL BOX 555 SE start up procedure: pre-heating TR ST PH N + M -

  37. CONTROL BOX 555 SE start up procedure: pre-heating TR ST PH N + PTC M -

  38. CONTROL BOX 555 SEstart up procedure: pre-heating TR ST PH N + PTC M -

  39. CONTROL BOX 555 SE start up procedure: pre-purge TR ST PH N 70° C + PTC M -

  40. CONTROL BOX 555 SE start up procedure: pre-purge TR ST PH N + PTC M -

  41. CONTROL BOX 555 SE start up procedure: pre-purge TR ST PH N + PTC M -

  42. CONTROL BOX 555 SE start up procedure: pre-purge TR ST PH N + PTC M -

  43. CONTROL BOX 555 SE start up procedure: pre-purge TR ST PH N 52 V AC 72V DC + PTC M - Timer is supplied (12”)

  44. CONTROL BOX 555 SE start up procedure: ignition TR ST PH N + PTC M -

  45. CONTROL BOX 555 SE start up procedure: ignition TR ST PH N + PTC M -

  46. CONTROL BOX 555 SE start up procedure: ignition TR ST PH N + PTC M -

  47. CONTROL BOX 555 SE start up procedure: ignition TR ST PH N + PTC M -

  48. CONTROL BOX 555 SE start up procedure: ignition TR ST PH N + PTC M -

  49. CONTROL BOX 555 SE start up procedure: ignition TR ST PH N + PTC M -

  50. CONTROL BOX 555 SE start up procedure: ignition TR ST PH N + PTC M M -