1 / 19

Nottingham Royal Concert Hall

Nottingham Royal Concert Hall. Nottingham Royal Concert Hall. Introduction – Project and Partners Background – Steve Poole Funding ( E.On ) – Rupert Butt Design Challenges (DES) – Paul Fisher Project Hardware (Projection) – Steve Poole Outcome – (NRCH) – Dave Guy

zocha
Télécharger la présentation

Nottingham Royal Concert Hall

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Nottingham Royal Concert Hall

  2. Nottingham Royal Concert Hall • Introduction – Project and Partners • Background – Steve Poole • Funding (E.On) – Rupert Butt • Design Challenges (DES) – Paul Fisher • Project Hardware (Projection) – Steve Poole • Outcome – (NRCH) – Dave Guy • Facts and Figures (Projection) – Steve Poole • Conclusions and Questions

  3. Nottingham Royal Concert Hall • Background • Project Scope • Replace existing Tungsten light source with LED • Retain the existing lighting points • Recreate exactly the same lighting feel • Compatible with existing DMX control system • Seamless dimming to zero • Viable ROI

  4. Energy Performance Contracting • A program of works where the capital cost is recovered through energy savings which are guaranteed by E.ON £ £ £ Implementation costs (incl. financing) Guaranteed savings p.a. Client net benefit £ Savings in the early years repay the initial capital investment thereby limiting client risk £ £ £ £ £ Guaranteed savings period Ongoing savings

  5. Nottingham Energy Performance Contract • E.ON secured a contract under the RE:FIT Framework to deliver an EPC for Nottingham City Council. • £1.2M Investment to deliver a 26% energy saving across 8 buildings, including Leisure Centres, Care Homes and a Sports Stadium. • All savings guaranteed for 7 years in order to pay back the original investment. • One of the 8 Buildings is the Royal Concert Hall.

  6. Nottingham Royal Concert Hall • Design Challenges (DES) • The issues that needed to be resolved • Sourcing suitable product • Existing light fittings • Consistent and effective dimming • Control interface • The building • Emergency Lighting • Commissioning

  7. Nottingham Royal Concert Hall • Design Challenges (DES) • Existing Fittings (High Level) • 300W Par Lamps

  8. Nottingham Royal Concert Hall • Design Challenges (DES) • The Building

  9. Nottingham Royal Concert Hall • Project Hardware – AlphaLED • High Level Lighting (20m+ Height) • 60 x Bespoke fittings created • Mechanical Interface • 2700 CCT – To match tungsten “feel” • 3000Lm 28° Beam • For punch and penetration. • Replaced 300W R95 lamps

  10. Nottingham Royal Concert Hall • Project Hardware – AlphaLED • Low Level Lighting • 458 Down lighters • Across 4 levels. • 2700 CCT • Match tungsten feel • 700lm @ 11.5 TCW. • Replaced 75W Lamps

  11. Nottingham Royal Concert Hall • AlphaLED Attributes • Initial Colour Consistency • 1 x 2 step SDCM specification. • Consistent wall washing • Colour Consistency Guaranteed • No colour shift over life • (5 years, 50,000 hrs) • Low Lumen Depreciation • L95 50,000 hrs capability

  12. Nottingham Royal Concert Hall • Control Gear • DMX Capable – Dim to Zero Light level • EldoLEDPowerdrive.

  13. Nottingham Royal Concert Hall • Outcome – Theatre Prospective • LED/energy saving houselights and dimming, the bottom 10% • Maintenance and consumable savings (700 bulb changes a year previously) • Audience reaction to the change

  14. Nottingham Royal Concert Hall • Facts and Figures

  15. Nottingham Royal Concert Hall • Facts and Figures • The comparison is made assuming the lighting is used in the same way as the existing lighting.

  16. Nottingham Royal Concert Hall • Use control for further energy savings • Tungsten to LED – saves 85% energy Further energy Savings are possible: • LED with DMX allows for various dimming profiles • Set 100% for Theatre Customer use • Set 65% for cleaning • Set 50% at other times • These are examples only

  17. Nottingham Royal Concert Hall • Possible to double the saving • Don’t forget to consider use and control

  18. Nottingham Royal Concert Hall • Conclusions • Substantial Energy Savings are possible • Light Quality can be matched • Day to day maintenance eliminated • Further substantial savings with controls • Hardware guaranteed 5 years 50,000hrs

  19. Nottingham Royal Concert Hall • Any questions ? Thank You AlphaLED Stand D11