1 / 20

FCal Energy Scale Predictions J.Rutherfoord 9 June 2003

FCal Energy Scale Predictions J.Rutherfoord 9 June 2003. Overview. The signal path Signal pulses Calibration pulses The inputs and uncertanities Summary predictions. Points of Reflection. At interconnect (but neglect this) Off distributed Ohmic resistance of cable At coupling capacitor

Télécharger la présentation

FCal Energy Scale Predictions J.Rutherfoord 9 June 2003

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. FCal Energy Scale PredictionsJ.Rutherfoord9 June 2003

  2. Overview • The signal path • Signal pulses • Calibration pulses • The inputs and uncertanities • Summary predictions J. Rutherfoord

  3. J. Rutherfoord

  4. Points of Reflection • At interconnect (but neglect this) • Off distributed Ohmic resistance of cable • At coupling capacitor • At transformer (but neglect this except for sick channels) • At vacuum and pedestal cables • At imperfect matching of preamp input impedance to cable • At many other smaller (negligible?) locations J. Rutherfoord

  5. FCal Electronics Chain 1 May 2003 1 4 9 11 12 5 8 16 14 15 10 13 Vacuum Cable and Pedestal Cable FCal Module Summing Board Front End Board Calib Pulser Preamp Shaper Pipeline Gain Offset ADC J. Rutherfoord

  6. Signal Limits • Pipeline limits signal size (2nd lobe) • Switch from Shaper High Gain to Medium Gain • At 130, 260, and 300 GeV respectively for FCal1, FCal2, and FCal3 J. Rutherfoord

  7. J. Rutherfoord

  8. Triangle shape • In principle, many things modify the shape of the triangle pulse. But none are significant. • The significant parameters are • initial current • the drift time J. Rutherfoord

  9. J. Rutherfoord

  10. J. Rutherfoord

  11. J. Rutherfoord

  12. out 10 H (1.8 H) 50  1.53 A/CalDAC 14 Channels in all; 4 shown in Injection R 695  … + preamp cable Calibration Pulser System J. Rutherfoord

  13. J. Rutherfoord

  14. J. Rutherfoord

  15. Courtesy of Adam and Petr J. Rutherfoord

  16. J. Rutherfoord

  17. Table of FCal Signal Parameters J. Rutherfoord

  18. J. Rutherfoord

  19. J. Rutherfoord

  20. Summary Prediction • Signal (on the electron scale) and noise, both at High Gain Signal Noise (ADC Counts/GeV) (ADC Counts) FCal1 12.8 2.9 FCal2 6.5 2.9 FCal3 5.8 2.9 J. Rutherfoord