1 / 20

WP 5 DOME and RISER-TUBE ASSESMENT (STRUCTURAL BEHAVIOUR) Solver: ABAQUS standard 6.6.4 March 2007

WP 5 DOME and RISER-TUBE ASSESMENT (STRUCTURAL BEHAVIOUR) Solver: ABAQUS standard 6.6.4 March 2007. DOME DETAILS: Number of cables: 12. Material: Dyneema. Young modulus: 65130 MPa. Diameter: 98 mm. Section: 4970 mm2. Minimum Break Load: 5838 kN. FE model.

Télécharger la présentation

WP 5 DOME and RISER-TUBE ASSESMENT (STRUCTURAL BEHAVIOUR) Solver: ABAQUS standard 6.6.4 March 2007

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. WP 5 DOME and RISER-TUBE ASSESMENT (STRUCTURAL BEHAVIOUR) Solver: ABAQUS standard 6.6.4 March 2007

  2. DOME DETAILS: • Number of cables: 12. • Material: Dyneema. • Young modulus: 65130 MPa. • Diameter: 98 mm. • Section: 4970 mm2. • Minimum Break Load: 5838 kN. • FE model. Boundary conditions: x, y, z displacements constrained. Truss elements (only axial stiffness) Rigid ring.

  3. SCENARIO 1: - Vertical load (1000 or 2000 Tn) F vertical Linear behaviour is verified

  4. A’ A Lateral reaction at the top of the dome due to the current over riser tube: 1,182·106 N. • SCENARIO 2: • Vertical load (1000 or 2000 Tn) • + • Lateral load 118 Tn. F vertical F lateral Non linear behaviour is observed

  5. SCENARIO 3: • Vertical load (1000 or 2000 Tn) • + • Lateral load 118 Tn. • + • Pressure over dome due to current. Integrated by 5 concentrated loads in each cable. Every 20 meters height. F vertical F lateral

  6. Based on the small differences showed beside for the two different speeds analysed, the same pressure distribution (Cp-values) has been used to obtain the pressure at different speeds. P = 0.5 * Cp * density * vel^2

  7. SCENARIO 3 (1000 Tn): ANCHORING LOADS

  8. SCENARIO 3 (2000 Tn): ANCHORING LOADS

  9. SCENARIO 3 (2000 Tn – speed 0.6 m/s): CABLE STRESSES

  10. SCENARIO 3 (1000 Tn): CABLE STRESSES

  11. SCENARIO 3 (2000 Tn): CABLE STRESSES

  12. SCENARIO 3. VERTICAL DISPLACEMENT OF THE RIGID RING. Ring displacement

  13. SCENARIO 3. HORIZONTAL DISPLACEMENT OF THE RIGID RING. Ring displacement

  14. RISER TUBE DETAILS: • Detailed FE model of riser tube between two rings (50m). • Cables: • Number: 6. • Material: Dyneema. • Diameter: 98 mm. • Young modulus: 65190 MPa. • Section: 4970 mm2. • Minimum Break Load: 5838 kN. • Pipe: • Outer diameter: 2m. • Wall thickness: 76.9mm (77mm). • Material: PE100. • Modulus of elasticity at time cero: 1050MPa. • Modulus of elasticity after 50 years: 200MPa. • Design stress at time cero: 9.4MPa. • Design stress after 50 years: 6.3 MPa.

  15. Boundary Conditions and Loads: • Vertical load: (1000Tn and 2000Tn). • Pressure map around the tube (1,29 m/s). • P = 0.5 * Cp * density * vel^2

  16. RISER TUBE DETAILS: • Hypothesis: • Detailed FE model of riser tube between two rings (50m). • Rigid and fixed rings. • Only lateral forces transmitted between cables and tube. • (vertical pre-tension is not transmitted to the PE-pipe). • At time 0: • Maximum lateral displacement of PE pipe between two rigid rings: 131mm • After 50 years: • Maximum lateral displacement of PE pipe between two rigid rings: 680mm

  17. RISER TUBE DETAILS: • Hypothesis: • Detailed FE model of riser tube between two rings (50m). • Rigid and fixed rings. • Properties at time 0. • Only lateral forces transmitted between cables and tube. • (vertical pre-tension is not transmitted to the PE-pipe). At time 0: Maximum stress of PE tube between two rigid rings: 1.67MPa (Design stress at time cero: 9.4MPa) After 50 years Maximum stress of PE tube between two rigid rings: 1.75MPa (Design stress at time cero: 6.3MPa)

  18. RISER TUBE DETAILS: Cable stresses:

  19. CONCLUSIONS: • Dome: • The dome is feasible till a bottom current velocity of about 0.3 a 0.4 m/s (without taking into account dynamic effects) • Riser tube: • A riser tube with rings minimal every 50 meter is needed to avoid large displacements of the tube within the Dyneema cables

More Related