1 / 13

CMACS Workshop 2011 group2

CMACS Workshop 2011 group2. Avessie Amedome , Diquan Moore, Dana Pardi . Changing the Parameters. Tau-Fi Tau -Si Fast sodium channel vs calcium channel . Difference in action potential from the same set of parameters TFI=0.05 and TSI=1.75 . Apcell102. Apcell922. Tau Fi = 0.05.

darius
Télécharger la présentation

CMACS Workshop 2011 group2

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. CMACS Workshop 2011group2 AvessieAmedome, Diquan Moore, Dana Pardi.

  2. Changing the Parameters • Tau-Fi • Tau-Si • Fast sodium channel vs calcium channel 

  3. Difference in action potential from thesame set of parameters TFI=0.05 and TSI=1.75 Apcell102 Apcell922

  4. TauFi = 0.05 TSI_2.25 TSI_2.0

  5. TauFi= 0.075 TSI=1.50 TSI=1.75

  6. TauFi=0.1 TSI=1.75 TSI=2.25

  7. Tau –Fi=0.2 TSI= 1.75 TSI=2.25

  8. Tip Trajectory Data .The tip trajectory graph shows the shape of the tip in a given simulation. .The X axis represent various TSI values and the Y-axis represent the TFI values. .An important point to notice is that when TFI>.20 and TSI> 1.5, the simulations do not produce stable spiral wave.

  9. * .20 .15 .10 .07 .05 TFI TSI 1.5 1.75 2.00 2.25 2.50 2.75 3.00 * *TFI > .20 and TSI >1.5 does not produce stable spiral wave

  10. Difficulties in Running Simulations • The computers were slow at time, but the super computers really helped. • Changing the parameters at the end of every simulation was very tricky especially having to remember to “clean” after every simulation. • We were not able to run all the simulation( total of 49). We had about half of the simultations.

  11. Questions we have • Why is the spiral wave unstable ( start to break up) when TFI>.20 and TSI>1.5. • What cause the spiral wave to start with one tip and then finish as two tips. • What is the future of 4vmodel

  12. Our Experiences at CMACS • It is a great experience working with accomplished people in their fields such as MrFlavio Fenton, great speakers such as MrGlimm. • More importantly it been very great meeting and working with student from different academic background. • Learning is so great and challenging when the subject in questions are new

  13. Conclusion • We are very happy to be part of this CMACS workshop. • This workshop would not have been the same with the amazing help of Professor Nancy Griffeth, Flavio Fenton, Robert Gilmour, Teri Grosso, EzioBartocci, Kai Zhao, RupinderShingh and Joshua Rogers. We Thank you for your help.

More Related