1 / 14

Microwave Measuring System, LB 356-456 Micro-Moist

1. 2. 3. 4. Microwave Measuring System, LB 356-456 Micro-Moist. Moisture Content in Coal is an important parameter: Preparation-Regulate Moisture Content Handling-Dust-Ice Transport-Weight Trading-Weight Calorific Value. 5. Microwave Measuring System, LB 356-456 Micro-Moist.

eavan
Télécharger la présentation

Microwave Measuring System, LB 356-456 Micro-Moist

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 1

  2. 2

  3. 3

  4. 4

  5. Microwave Measuring System, LB 356-456 Micro-Moist Moisture Content in Coal is an important parameter: Preparation-Regulate Moisture Content Handling-Dust-Ice Transport-Weight Trading-Weight Calorific Value 5

  6. Microwave Measuring System, LB 356-456 Micro-Moist • Microwave Transmission Techniques are the most accurate • method of determining moisture content of Coal • Attenuation/Area Weight • Phase Shift/Area Weight • Phase Shift and or/Attenuation 6

  7. Microwave Measuring System, LB 356-456 Micro-Moist Attenuation measurement can provide accuracy up to 1wt% moisture Temperature dependence error Bulk Density dependence error Particle size dependent error Conductivity dependent error 7

  8. Microwave Measuring System, LB 456 Micro-Moist Phase Shift Measurement: or (Combined Attenuation and Phase Shift) Independent of Temperature of Coal Independent of Particle Size variations INTEGRAL Area Weight Compensation Accuracy of 0.2 wt% moisture achievable 8

  9. Microwave Measuring System, LB 356-456 Micro-Moist Principle of Operation 9

  10. Microwave Measuring System, LB 354-356-456 Micro-Moist • The choice of 2.7-3.4 GHz frequency range: • Measurement of bulk, not surface. This provides a representative measurement • The temperature coefficient of free water crosses zero at 3 GHz • Attenuation due to ionic conductivity (salt content,…) is reduced at higher • frequencies • Frequency analysis over the frequency range provides phase measurement greater • than 360 deg with plausibility control 10

  11. Microwave Measuring System, LB 356 Micro-Moist 11

  12. Microwave Measuring System, LB 356 Micro-Moist Coal Preparation Plant: 12

  13. Microwave Measuring System, LB 356 Micro-Moist Coal Preparation Plant management reported precision of 0.4% moisture (one sigma RMS) 13

  14. Microwave Measuring System, LB 456 Micro-Moist • Product Improvements: • Reference cable can be replaced by short link if Toconstant • PT-100 Temperature Compensation with direct connection • Detector to Evaluation Unit uses FSK (Frequency Shift Keying) 14