1 / 5

FMD

FMD. DCS Status (on behalf of Borge Nielsen). C. FMD. 10. [FSM?]. 15/03/04. FMD DCS. DCS. Database(s). PVSS II. PVSS II. PVSS II. Control room (ACR). FMD DCS. OPC client. DIM client. User interface. Ethernet. [FED]. PVSS II. PVSS II. PVSS II. OPS client. OPC client.

faris
Télécharger la présentation

FMD

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. FMD DCS Status(on behalf of Borge Nielsen) DCS Workshop

  2. C FMD 10 [FSM?] 15/03/04 FMD DCS DCS Database(s) PVSS II PVSS II PVSS II Control room (ACR) FMD DCS OPCclient DIMclient User interface Ethernet [FED] PVSS II PVSS II PVSS II OPS client OPC client OPC client CAEN OPCserver CAEN OPCserver ? DIMserver PCI-CAN? PCI-CAN? PCI-CAN? E E C FMDDCS E 3 Counting room 1 1 CAEN CAEN ? ? DDL 3 TTC FMD-RCU Cavern P? LVL0 trig ? 10 HV LV LV 70 140 20 300? Inside magnet Detector Preamps FMD Digitizers High Voltage Preamps Digitizers Crate Control

  3. C FMD 10 [FSM?] 15/03/04 FMD DCS DCS Database(s) • High and Low Voltage • HV: CAEN (SY1527) • LV: Probably CAEN, maybe Wiener (cost aspects) • Might combine HV and LV boards in same CAEN mainframe PVSS II PVSS II PVSS II Control room (ACR) FMD DCS OPCclient DIMclient User interface Ethernet [FED] PVSS II PVSS II PVSS II OPS client OPC client OPC client CAEN OPCserver CAEN OPCserver ? DIMserver PCI-CAN? PCI-CAN? PCI-CAN? E E C FMDDCS E 3 Counting room 1 1 CAEN CAEN ? ? DDL 3 TTC FMD-RCU Cavern P? LVL0 trig ? 10 HV LV LV 70 140 20 300? Inside magnet Detector Preamps FMD Digitizers DCS Workshop High Voltage Preamps Digitizers Crate Control

  4. C FMD 10 [FSM?] 15/03/04 FMD DCS DCS Database(s) • Front End Electronics (RCU) • Copy as far as possible TPC solution • From RCU and up, identical to TPC • Considering to move RCU closer to the detector PVSS II PVSS II PVSS II Control room (ACR) FMD DCS OPCclient DIMclient User interface Ethernet [FED] PVSS II PVSS II PVSS II OPS client OPC client OPC client CAEN OPCserver CAEN OPCserver ? DIMserver PCI-CAN? PCI-CAN? PCI-CAN? E E C FMDDCS E 3 Counting room 1 1 CAEN CAEN ? ? DDL 3 TTC FMD-RCU Cavern P? LVL0 trig ? 10 HV LV LV 70 140 20 300? Inside magnet Detector Preamps FMD Digitizers High Voltage Preamps Digitizers Crate Control

  5. Interlocks • Similar to other Si detectors • Temperature, over-current • No active cooling system • For RCU, follow TPC DCS Workshop

More Related