1 / 8

Euso-balloon Lenses

Euso-balloon Lenses. Design: - Alex Zuccaro (now at ESTEC) - Yoshiyuki Takizawa (Takky): RIKEN Production: - Takky (RIKEN) - H. Ohmori (IKEGAMI & RIKEN) Measure of instrument focal length - Massimiliano Bonamente (Max): UAH Huntsville, Alabama Integration - Peter Von Ballmoos: IRAP

freja
Télécharger la présentation

Euso-balloon Lenses

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Euso-balloon Lenses • Design: • - Alex Zuccaro (now at ESTEC) • - Yoshiyuki Takizawa (Takky): RIKEN • Production: • - Takky (RIKEN) • - H. Ohmori (IKEGAMI & RIKEN) • Measure of instrument focal length • - Massimiliano Bonamente (Max): UAH Huntsville, Alabama • Integration • - Peter Von Ballmoos: IRAP • French representative: myself, on behalf of the Jem-Euso collaboration End of phase A meeting CNES (Toulouse) 2/02/2012 Ph. Gorodetzky APC - Paris Diderot

  2. Lenses Euso-balloon lenses JEM-EUSO (hence Euso-balloon) is a telescope made with lenses. • Why lenses instead of a mirror which is lighter? Because of ISS (and balloon) movements! • Why Fresnel: because of weight! • Tools used: Code V (and a faster ray-tracing program written by Yoshiyuki Takizawa (Takky)) and a TOSHIBA lathe UTD-3400 at IKEGAMI factory. End of phase A meeting CNES (Toulouse) 2/02/2012 Ph. Gorodetzky APC - Paris Diderot End of phase A meeting CNES (Toulouse) 2/02/2012 Ph. Gorodetzky APC - Paris Diderot 2

  3. Balloon lenses • 3 one sided lenses • square flat 1 x 1 m • 2 classical • 1 diffractive • both made of Shinkolite L PMMA-000 Radius of curvature of FS: 509 mm (implies the flat ECs will be at 5.6° one from each other) This is the result of a compromise between the smallest FOV required to recognize a shower and the angle of the rays on the FS End of phase A meeting CNES (Toulouse) 2/02/2012 Ph. Gorodetzky APC - Paris Diderot

  4. Spot sizes One MAPMT pixel is 2.88 x 2.88mm  stability of response End of phase A meeting CNES (Toulouse) 2/02/2012 Ph. Gorodetzky APC - Paris Diderot

  5. Positionning Optics Tolerances (RMS spot sizes change ±10%) No problem for the lenses, but the PDM must be on an axial manual movement Important difference between normal and Fresnel lens: It is easy to predict the focal length for a normal lens It is impossible to manufacture precisely a Fresnel lens with a predicted focal length: the total focal length could be ± 10 cm! So it is necessary to measure the true focal length of the system with a large parallel beam of the good wavelength (290 – 430 nm), measuring the PSF with fine granularity detector (CCD). This equipment is ready for us at UAH (Huntsville, Alabama) End of phase A meeting CNES (Toulouse) 2/02/2012 Ph. Gorodetzky APC - Paris Diderot

  6. Lenses mechanics End of phase A meeting CNES (Toulouse) 2/02/2012 Ph. Gorodetzky APC - Paris Diderot

  7. Development plan • Telescope SYSTEM • The Optical Lenses system consists in three PMMA lenses each having a Fresnel shaped face side and • the other side is flat. Riken laboratory has the responsibility of the calculation of the exact shape of the lenses for EUSO BALLOON. • The PMMA material will be provided by Mitsubishi Rayon Co., LTD. • The lenses are manufactured by IKEGAMI Molt Ltd in Japan. Series of Bread Board Module has already been produced • and there is no particular difficulty in the machining. Thus the process of fabrication has already been validated. • The FM will be directly produced by this company, under RIKEN responsibility. Each manufactured lens will be checked in • acceptance test in RIKEN. The optical performances of the set of three lenses will be checked in Riken. Then the three • lenses and the optical test system will be delivered to IRAP for the final acceptance Integration and Tests. End of phase A meeting CNES (Toulouse) 2/02/2012 Ph. Gorodetzky APC - Paris Diderot

  8. Risk analysis • Management: delay in lens delivery • Failure of the facility (IKEGAMI). Recovery time is estimated at 2 months and has been measured after big earthquake. Fabrication is estimated at 2 weeks / lens. Highest priority will be given. • Technological: a lens is damaged • Material for an extra lens will be stored in RIKEN. With high priority, the damaged lens will be replaced in 4 weeks. End of phase A meeting CNES (Toulouse) 2/02/2012 Ph. Gorodetzky APC - Paris Diderot

More Related