An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Very Forward Region Instrumentation Wolfgang Lohmann, DESY Basic functions: • Hermeticity to small polar angles • Fast and precise Luminosity measuremt • Shielding of the inner detectors- LDC meeting

  2. Shielding function 20mrad solenoid 20mrad DID • backscattering from pairs hitting the LumiCal edge LDC meeting

  3. Current design and Lumi measurement Head-on or small X-angle Gauge process: Bhabha Scattering Device: LumiCal 26 < q < 82 mrad BeamCal 300 cm VTX L* = 4m Beampipe FTD IP Accuracy (from Physics) O(<10-3)

  4. LumiCal LumiCal IP LumiCal Requirements on the Mechanical Design < 4 μm Requirements on Alignment and mechanical Precision (MC simulations, BHLUMI) Inner Radius of Cal.: < 4 μm Distance between Cals.: < 100 μm Radial beam position: < 0.6 mm < 0.6 mm

  5. Comparison head-on, 2, 20 mrad Radial beam shift: 400mm Centered around the outgoing beam Centered around the detector axis For a 20 mrad design LumiCal MUST be centered around the outgoing beam-pipe!

  6. Background in the LumiCal : (500 GeV, TDR) Zero or small X-angle: neglegible 20 mrad X-angle: 3-5 TeV Beamstrahlung pair background using serpentine field Number of Bhabha events as a function of the inner Radius of LumiCal 250 GeV Background from beamstrahlung

  7. Collaboration FCAL High precision design Head-on design Overlap region LumiCal rmin=8 cm rmax=28 cm BeamCal rmin=1.5 cm rmax=10 cm Beam hole ECFA2005 7

  8. Collaboration FCAL High precision design X- angle design (2 mrad) LumiCal rmin=13 cm rmax=28 cm (Reasonable Statistics) BeamCal rmin=2 cm rmax=16 cm Beam hole Larger hole for the beampipe  less Shielding for the inner detector ECFA2005 8

  9. Detectors are centered around the outgoing beam Collaboration FCAL High precision design X- angle design (step-2) BeamCal + 30o blind area (incoming beam) ECFA2005 9

  10. Technology Sensor carriers Si/W sandwich calorimeter, simulations at advanced level. No hardware devolepment up to now. Absorber carriers Mechanical frame: Decouple sensor support from absorber support structure

  11. BeamCal Zero (or 2 mrad) crossing angle • e+e-Pairs from Beamstrahlung are deflected into the BeamCal • 15000 e+e- per BX 10 – 20 TeV (10 MGy per year) • direct Photons for q < 200 mrad GeV 20 mrad Crossing angle Background in the BeamCal : (500 Gev, TDR) Zero or small X-angle: 30 TeV/BX 20 mrad X-angle: 60 TeV/BX

  12. Solutions for 20mrad X-angle Enlarge the radius of BeamCal DID, 20 mrad DID, large aperture (Ri(LumiCal) > 13cm) 20mrad AntiDID Anti-DID Field

  13. Detection of High Energy Electrons and Photons (Detector Hermeticity) √s = 500 GeV Single Electrons of 50, 100 and 250 GeV, detection efficiency as a function of R (‘high background region’) Detection efficiency as a function of the pad-size Red – high BG blue – low BG Message: Electrons can be detected!

  14. Beam Parameter Determination with BeamCal Observables total energy first radial moment thrust value angular spread L/R, U/D F/B asymmetries 20 mrad crossing angle Also simultaneous determination of several beam parameter is feasible, but: Correlations! Analysis in preparation PRELIMINARY!

  15. Technology for the BeamCal: • Radiation Hard • Fast • Compact W-Diamond sandwich sensor Space for electronics

  16. For a small crossing angle a pretty advanced design of the very forward region is worked out For 20 mrad crossing angle some studies are redone The forward calorimeters must be centered around the outgoing beampipe • -Complex mechanics • -interference with ECAL • -difficult background situation FE electronics – so far some ideas