1 / 35

3 rd Annual Progress Energy Symposium UCF Solar Farm: Photovoltaic Array – Mounting System

3 rd Annual Progress Energy Symposium UCF Solar Farm: Photovoltaic Array – Mounting System. Project Engineers: Daniel Gould Connie Griesemer Ryan Lewis Jonathan Torres Ryan Tribbey College of Engineering and Computer Sciences Department of Mechanical, Materials and Aerospace Engineering.

lancesparks
Télécharger la présentation

3 rd Annual Progress Energy Symposium UCF Solar Farm: Photovoltaic Array – Mounting System

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 3rd Annual Progress Energy SymposiumUCF Solar Farm:Photovoltaic Array – Mounting System Project Engineers: Daniel Gould Connie Griesemer Ryan Lewis Jonathan Torres Ryan Tribbey College of Engineering and Computer Sciences Department of Mechanical, Materials and Aerospace Engineering

  2. Purpose: UCF’s Climate Action Plan • In 2008 UCF spent $12.5 Million in Electrical Consumption • Approximately 4-9% increase annually • February 2007 President Hitt took a stand for sustainability and to become a climate neutral campus by 2050 Carbon Mitigation Energy Conservation Energy Efficiency Fuel Switching Renewable Energy

  3. UCF Solar Farm – Project Site Area of Site – 3 Acres ; equivalent to 0.6 MW

  4. 11 Vertical Panels over Twin Cylindrical Horizontal Rails, 4 Support Posts per Rail (8 total) Total Weight – 917 lbs Overall Size – 38’ 6” x 4’ 9” Distance between arrays – 5’ Total Number of Panels – 3934 Total Number of Arrays - 357

  5. Side Profile – Attachment System Bushing 3.5 ft Bracket 1 ft Set at Optimal Angle of 29o

  6. Wind Load Analysis(Wind Flowing Front to Back) Vertical Lift = -4778 lbf

  7. Wind Load Analysis(Wind Flowing Back to Front) Vertical Lift = +4132.5 lbf

  8. The Final Module

  9. Special Thanks To: 3rd Annual Progress Energy SymposiumUCF Solar Farm:Photovoltaic Array – Mounting System • Sponsor – UCF Sustainability & Energy Management, David Norvell, PE CEM • Faculty Advisor: Nina Orlovskaya, Ph.D. • Technical Advisors : • Patrick Robinson, Florida Solar Energy Center • James Nelson, Kennedy Space Center • College of Engineering and Computer Sciences, Department of Mechanical, Materials and Aerospace Engineering

  10. 3rd Annual Progress Energy SymposiumUCF Solar Farm:Photovoltaic Array – Monitoring System Project Engineers: Michael Gannon Michael Peffers Muhammed Ali Khan Ahmad Buleybel College of Engineering and Computer Sciences Department of Electrical Engineering and Computer Science 

  11. Solar Farm - Project Overview • Design a panel by panel monitoring system • Monitoring system must be self sustaining • Wirelessly transmit data • Data will be collected every 5 minutes for duration of the day • Publish real time information online • Data must be graphed for easy interpretation • Publically accessible

  12. Solar Farm - Solar Panels • 11 Solar panels used – Sharp Nu-U240f1 • 240 Watts • 37.4 Volts • 8.65 Amps • Weight: 44.1lbs/ 20.0 kg • These panels will be connected in a series circuit with one another • Locally distributed 39 inches 64.5 inches

  13. Solar Farm - Design Goals & Objectives • Monitor each panel for: • Voltage • Temp • Current • Display data online in real time • Transmit data from field to web server wirelessly

  14. Solar Farm - Primary Circuit Board System Power • This board will handle power to the whole system for all components • Change channels on the Multiplexers that were implemented • Handle all wireless communication RJ45 Cable Optical Sensor 16:1 Multiplexer Power to whole system PIC18F87J11

  15. Solar Farm - Secondary Circuit Board • Board will consist of three separate sensors • Voltage, Current, and Temperature • All sensors are hardware designed to an accuracy at least ± 1.5% Solar Panel Current Sensor Temp Sensor Voltage Sensor 4:1 Multiplexer

  16. Solar Farm - Multiplexer • A multiplexer or MUX is a device that combines several electrical signals into a single signal. There are different types of multiplexers for analog and digital circuits. • Programming the MUX gives desired values. Figure: Pin Out for 4:1 Mux

  17. Actual Secondary PCB LM351 Op-Amp Voltage Regulator Temperature Sensor

  18. Solar Farm - Wireless Technology • XBee PRO 802.15.4 • Range - Indoor Range 300 ft. - Outdoor Range 1 mile • No monthly fee • Low complexity. • Perfect for low-data transfer. • Very low power requirement. • Two modules, transmitter and receiver.

  19. Solar Farm – Wireless Transmission

  20. Solar Farm – Real Time Monitoringwww.ucfprojecthelios.co.cc

  21. Special Thanks To: • Sponsor – UCF Sustainability & Energy Management, Dave Norvell, PE CEM • Technical Advisor – Dr. Samuel Richie • Mechanical Engineers: Industrial Engineers: • Daniel Gould Amanda Longman • Connie Griesemer Joshua MacNaughton • Ryan Lewis Andrew Wolodkiewicz • Jonathan Torres • Ryan Tribbey

  22. UCF Photovoltaic Solar Farm Project Amanda Longman Joshua MacNaughton Andrew Wolodkiewicz

  23. Presentation Outline • Why Photovoltaic? • Goal of the Project • Prototype Design • Forecast Analysis • Conclusions • Future Considerations

  24. Why Photovoltaics at UCF? • Energy from the sun is renewable • Power guaranteed for 25 yrs • Clean, environmentally friendly, and silent • On-site energy production • Capacity is available on campus • President John Hitt engaged UCF in the President’sClimate Commitment General Reasons UCF-Specific Reasons

  25. 13 Florida Colleges and Universities1 • Eckerd College • Florida Atlantic University • Florida Gulf Coast University • Florida International University • Hillsborough Community College • New College of Florida • Stetson University • University of Central Florida • University of Florida • University of Miami • University of North Florida • University of South Florida • Valencia Community College 1Obtained from http://www.presidentsclimatecommitment.org/ April 4, 2011

  26. Solar Farm Project Goals • Conduct a feasibility study of constructing a 3-MW solar farm on the UCF main campus • 3 MW will supply approximately 15% of the peak energy demand on the main campus (Norvell, 2010) • Project involves constructing design prototype • Multidiscipline senior design team (MEs, EEs, and IEs)

  27. Prototype Design • Sharp NU-U240F1 (240 W) Solar Panel • Selection driven by low shipping costs from local distributor • Fixed mounting system • Minimal maintenance • Supports 11 solar panels • Individual panel monitoring • Allows for immediate control of system malfunctions

  28. Forecast AnalysisPrototype Benefits2 • Take 0.548vehicles off the road • Eliminate CO2 emissions from 0.339homes • Eliminate CO2 emissions from 117propane cylinders used for home barbeques • Save UCF $283.30/year Each year, the prototype (0.003 MW) can: 2 Obtained from http://www.epa.gov/cleanenergy/energy-resources/calculator.html#results, April 4, 2011

  29. Forecast AnalysisTransitioning from 0.003-MW Design to 3-MW Design • Panel requirements: 11panels to 12,507panels • This requires 1,137 arrays • Space is necessary between rows • Land requirements: 240 sq ft to 653,400 sq ft • 0.006 acres to 15 acres • More than 11 football fields

  30. Forecast Analysis3-MW Design Benefits3 Each year, the 3 MW Solar Farm Can Eliminate: • Greenhouse gas emissions from approximately 623 vehicles • CO2 emissions from the electricity use of 386 homes • CO2 emissions from 132,487 propane cylinders used for home barbeques • $322,110/year from UCF energy bill 3 Obtained from http://www.epa.gov/cleanenergy/energy-resources/calculator.html#results, April 4, 2011

  31. Future Considerations • Florida weather conditions • Variation in daily output Sunny Day CloudyDay

  32. Future Considerations 2006 – 17% Eff. 3.5 kW • Advancements in solar technology • Increased efficiency • Decreased costs 2006 – 14% Eff. 3.5 kW 1988 – Experimental Thin Film 3.5 kW Corner of University Dr. & Econlockhatchee Trl.

  33. Photovoltaic Solar Farm Project Outcomes • Success of this project is greatly influenced by the multidisciplinary nature of the design team • Additional resources needed for large-scale expansion • This study supports the University’s commitment of becoming climate-neutral

  34. Team Accomplishments • Mechanical Engineers designed the mounting system • Electrical Engineers designed the monitoring and communication system • Industrial Engineers computed the design forecasts for a 3-MW solar farm

  35. Acknowledgments University of Central Florida Corporate Thanks • Client: Mr. David Norvell • Asst: Gina Spahi • Faculty Advisors • Dr. Christopher D. Geiger (IEMS) • Dr. William J. Thompson (IEMS) • Dr. Samuel Richie (EECS) • Electrical Engineering Design Team • Mechanical Engineering Senior Design Team • Progress Energy • Kennedy Space Center • Florida Solar Energy Center • Superior Solar