1 / 1

INTRODUCTION AND OBJECTIVES

COMPARATIVE DETERMINATION OF ZINC IN PHARMACEUTICAL PRODUCTS. CORCIOVĂ ANDREIA, CIOBANU CONSTANTIN. “Grigore T. Popa” University of Medicine and Pharmacy Iasi, Faculty of Pharmacy, Department of Drugs Analysis, Pharmaceutical legislation and deontology, Iasi, Romania.

lilli
Télécharger la présentation

INTRODUCTION AND OBJECTIVES

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. COMPARATIVE DETERMINATION OF ZINC IN PHARMACEUTICAL PRODUCTS CORCIOVĂ ANDREIA, CIOBANU CONSTANTIN “Grigore T. Popa” University of Medicine and Pharmacy Iasi, Faculty of Pharmacy, Department of Drugs Analysis, Pharmaceutical legislation and deontology, Iasi, Romania INTRODUCTION AND OBJECTIVES MATERIAL AND METHODS Nowadays, the use of dietary supplements based on vitamins, micro and macro elements is widespread.Zinc is the second transition metal after iron in terms of importance and its levels in the human body therefore is essential to a healthy growth and development (1). So maintaining an optimal level of zinc in the body is very important. For this purpose, continuous monitoring of the concentration of zinc in dietary supplements is of great importance. The present work describes two analytical methods (spectrophotometry and atomic absorption spectrometry) used for the quantitative determination of zinc in three pharmaceutical preparations (2). For the UV-Vis spectrophotometric method a Jasco V 530 double beam UV-Vis spectrophotometer was used andfor the FAAS method a flame high resolution continuum source atomic absorption spectrometer (ContrAA 300, Analytic Jena, Germany). The spectrophotometric method is based on the formation of a zinc-dithizone red complex (Figure 1) which is soluble in chloroform, having maximum absorbance at 516 nm. For the second proposed method (atomic absorption spectrometry) the sample was wet digested using a mixture of concentrated nitric acid and hydrogen peroxide, after which the absorbances were recorded using an atomic absorption spectrometer at 213.857 nm. The performance parameters for both methods were evaluated.Samples were labeled: sample 1 (15 mg zinc/tablet), sample 2 (10 mg zinc/tablet), sample 3 (5 mg zinc/tablet). RESULTS Linearity:for Method 1 zinc was found to be linear in the range of 0.05 - 1 mg % and for Method 2, the analytic response was linear in the range of 0.25 – 3 mg/L. Figure 2 and 3 present the obtained calibration curves . Repetability:The precisions of the systems were studied for the concentrations of 0.5% for method 1 and for 1.6 mg/L for method 2. The statistical analysis leads to relative standard deviations of 0.1189% (method 1) and 0.7745% (method 2) compared to the maximum of 2% set by European standards, so the systems are considered precise. Figure 1. Reaction of zinc with dithizone Precision of the methods and accuracy:To determine the accuracy of the spectrophotometric method, 3 concentration levels were used and for each level 3 determinations were performed. Average recovery values ​​were in the range of 99.00 - 101.38% with % RSD = 0.161 - 0.743 for method 1 and 100.02 – 101.18% with % RSD = 1.7091 – 2.6975 for method 2. The % RSD of the recovery values ​​in 3 different days were in the range 0.422-0.685 for method 1 and 0.853-1.369 for method 2. As shown, the values ​​of % RSD are less than 5, the amount proposed by European standards, which means that the methods are accurate. Zinc determination in pharmaceutical preparations. Both methods have been applied for the determination of zinc in 3 pharmaceutical preparations (tablets). Figure 4 presents the zinc concentrations found in the analyzed pharmaceutical products and figure 5 shows the obtained recoveries. The obtained results are in accordance with the limits imposed by the British Pharmacopoeia ed. 2013, Tablets Monography and European Pharmacopoeia, Monoghraph 0478. Figure 2. Calibration curve for method 1 Figure 3. Calibration curve for method 2 Figure 4. Zinc concentrations found in the analyzed samples Figure 5. Zinc recoveries obtained for the analyzed samples CONCLUSIONS REFERENCES Both methods are precise, simple, however each has its advantages and disadvantages. While the used spectrophotometric method is time consuming and needs more reagents, the FAAS is faster and uses less reagents. On the other hand, the UV-Vis method is cheaper and doesn’t require sophisticated equipment. In conclusion, it has been demonstrated that the proposed methods can be successfully used for the determination of zinc in pharmaceutical preparations. • Frederickson CJ, Koh JY, Bush aI. The neurobiology of zinc in health and disease. Nat Rev Neurosci. 2005;6:449-462. • McCall KA, Huang C, Fierke CA. Function and mechanism of zinc metalloenzymes. J Nutr.2000;130:1437S-1446S.

More Related