Experience with a new 4 loop haptics apodized diffractive hydrophilic multifocal IOL

Experience with a new 4 loop haptics apodized diffractive hydrophilic multifocal IOL. Ruth Lapid-Gortzak MD PhD 1,2 Ivanka van der Meulen MD 1,2 Jan Willem van der Linden Boptom . 2 1. AMC, University of Amsterdam 2. Retina Total Eye Care, Driebergen

nardo
Télécharger la présentation

Experience with a new 4 loop haptics apodized diffractive hydrophilic multifocal IOL

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Experience with a new 4 loop hapticsapodized diffractive hydrophilic multifocal IOL Ruth Lapid-Gortzak MD PhD1,2 Ivankavan der Meulen MD1,2 Jan Willem van der Linden Boptom. 2 1. AMC, University of Amsterdam 2. Retina Total Eye Care, Driebergen Financial Disclosure: Dr. Lapid is a speaker for Alcon, Hanita Lenses, MSD, Oculentis, and a clinical investigator for Alcon. Mr. Van der Linden and Dr. van der Meulen have no interest to disclose.

  2. Purpose • To report the outcomes in terms of visual acuity, refraction, incidence of halos at 3 months after implantation with a new 4 loop haptic apodized diffractive hydrophilic multifocal IOL (MFIOL), the BunnyLens (Hanitalenses, Israel)

  3. Methods: Prospectiveinterventional case cohort Standard phacoemulsification 2.2 mm incision, eitherfor cataract or refractive lens exchange. Outcomemeasures: uncorrectedandcorrecteddistanceacuity, uncorrectednearacuity, incidence of halos, historicalcomparisonwithcohorts of apodizeddiffractivehydrophiliclenses, (SeeLens MF, Hanitalenses, Israel) apodizeddiffractivehydrophobic lens (SN6AD1, ReSTOR, Alcon), and a radiallyasymmetricrefractive IOL (LS-312 , Mplus lens, Oculentis, Germany)

  4. Results at 3 monthspostoperatively:

  5. HistoricalComparison van der Linden et al, JCRS January 2012 van der Linden et al, International Ophthalmology, January 2013

  6. Conclusion: The BunnyLens MF (HanitaLenses, Israel) performswell in a small prospective cohort. The IOL performs on par withhistorical data of otherlenses, like the SeeLens MF (HanitaLenses), the SN6AD1 (Restor, Alcon, USA), and the LS-312 (Mplus, Oculentis, Germany The hydrophilicapodizeddiffractive type of IOL seemstoinducelessdysphotopsias, but more study is neededtoconfirmthis.