1 / 15

Hybrid Testing Status

Hybrid Testing Status. Lance Simms 6/22/04. With old software things were okay…. Opens, shorts, and noisy channels detected Automatic XML uploading Cuts adjustable from configuration files Manual mode ARCS available for hardware troubleshooting

teal
Télécharger la présentation

Hybrid Testing Status

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Hybrid Testing Status Lance Simms 6/22/04 Slide 1

  2. With old software things were okay… • Opens, shorts, and noisy channels detected • Automatic XML uploading • Cuts adjustable from configuration files • Manual mode ARCS available for hardware troubleshooting • Automatic report.txt file uploading to local database (UCSB only) Slide 2

  3. But pretty ghetto for the most part • Hybrids that failed at -20… a mystery; simply swept aside. • XML files contain only -Flagged channels -Pedestal -Operator -Noise -Test Script used -Tool ID -Date/Time of test Slide 3

  4. Even worse… • False channel identification for six-chip hybrids (only seen in three cases) • TESTWITHPA_val held at 0 regardless of test outcome • Only two grades: PASS/ FAIL • One or more shorted channels OR five or more noisy OR open channels -> Hybrid fails Slide 4

  5. Now Underlying DAQ library can be compiled * * Microsoft Visual C++ 6.0 or higher required Slide 5

  6. Latest Teststation version in use at CERN is now operational and modifiable • Labview source code can be changed and recompiled into an executable file • Allows UCSB/FNAL specific adjustments such as readout of air/water flow sensor in ACDC • MUX, PLL, DCU, etc. are now accessible through C++/labview interface * *Not possible with code currently in use at UCSB & FNAL; dll source was not available Slide 6

  7. Features of New Software • PLL status check • PLL Forcing (If necessary) • Drifting Pedestal Check • New Hybrid Grading: A/B/Fail • XML generation (Not automatic yet) • Manual mode disabled Slide 7

  8. PLL Failure? Take those old hybrids off the shelf • Initialization now talks to PLL • Reads bit 0 of PLL Control and Status register 1 • 1 if PLL is “going” • the norm after reset sequence • PLL operation is controlled by auto calibration circuit • 0 if PLL is “not going” • Occurs at -20 C • Requires PLL “forcing”: PLL operation is controlled by I2C interface • Hybrid will initialize in cold Slide 8

  9. PLL comment in report & XML file Slight problem: For some reason pedestal and noise have increased edges with new software. Probably something simple. Slide 9

  10. Open Vias should be found • Final report vi compares the average pedestal for each APV between tests • If pedestal drifts, comment will be made in report.txt and XML file Slide 10

  11. New Grading: Agreement with CERN "TIB_P_4D", "TOB_P_4U".."TOB_S_4D", "TEC_4U" 0-2 noisy or open channels "A" hybrid 3-4 noisy or open channels "B" hybrid 5+ noisy or open channels “Failed” One or more shorted channels* “Failed” "TIB_S_6U".."TID_S_6D", "TOB_P_6U", "TEC_6U", "TEC_6D" 0-3 noisy or open channels "A" hybrid 4-6 noisy or open channels "B" hybrid 7+ noisy or open channels “Failed” One or more shorted channels* “Failed” *New code still allows for only one channel to be flagged as short. A consensus should be made as to what constitutes a short. Slide 11

  12. XML Generation • Bruno Wittmer (teststation architect) is person associated with XML files • XML files output by new software should contain everything in old files + * • Comments on PLL & Drifting Pedestal • TESTWITHPA_val indicating grade of hybrid • Automatic uploading will be added *Still have not successfully generated XML file with new code Slide 12

  13. Additions to Code • CVS repository at CERN contains all updates http://cms-project-cmstobss.web.cern.ch/cms-project-cmstobss/ • CVS tools available in linux * and Windows, making updating easy • US can contribute • *Documentation: http://cmsdoc.cern.ch/cmsoo/projects/cvs_server.html Slide 13

  14. Equipment • One spare peltier in US • Ours has failed due to overheating once • ARC boards (Ask Tony) • One spare crate at UCSB (belongs to Fermilab/going to Mexico City) • NIM modules (1 of each used in pulser) • Spare humidity & temperature sensors • 2 peltier power supplies • No spare chiller (Perhaps one should be purchased) Slide 14

  15. Documentation & AOB • Documentation on ARCS, ACDC, XML files, etc. will be collected, organized, and posted on web • Side by side updating of code at UCSB and Fermilab Slide 15